{"id":71772,"date":"2026-11-25T06:47:06","date_gmt":"2026-11-25T06:47:06","guid":{"rendered":"https:\/\/www.eabel.com\/?p=71772"},"modified":"2026-11-25T06:47:09","modified_gmt":"2026-11-25T06:47:09","slug":"progettazione-layout-centro-dati","status":"publish","type":"post","link":"https:\/\/www.eabel.com\/it\/data-center-layout\/","title":{"rendered":"Progettazione del layout di un centro dati: guida e buone pratiche"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"71772\" class=\"elementor elementor-71772\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4e4befe e-flex e-con-boxed e-con e-parent\" data-id=\"4e4befe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e11925 elementor-widget elementor-widget-text-editor\" data-id=\"3e11925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">Il layout di un centro dati \u00e8 la disposizione fisica dei rack IT, delle apparecchiature di alimentazione e raffreddamento, dei percorsi dei cavi e delle aree di servizio. Dovrebbe indicare dove trovano posto le apparecchiature e come saranno alimentate, raffreddate, sottoposte a manutenzione e sostituite.<\/p><p class=\"p1\">Partite dai requisiti delle apparecchiature, quindi traduceteli in zone, file e percorsi. Questa guida segue il processo attraverso un esempio di calcolo con 20 rack e le verifiche prima dell\u2019installazione. Riguarda sia i nuovi locali sia le strutture esistenti, dove le apparecchiature fisse e le finestre di fermo aggiungono vincoli.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3029474 e-flex e-con-boxed e-con e-parent\" data-id=\"3029474\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e76837e elementor-widget elementor-widget-text-editor\" data-id=\"e76837e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Punti chiave<\/h2>\n<ul><li>Progettate a partire dal carico, dalle dimensioni e dai requisiti di raffreddamento di ciascun rack.<\/li><li>Riservate percorsi per la consegna, la manutenzione e la sostituzione delle apparecchiature.<\/li><li>Coordinate gli impianti nelle sezioni verticali oltre che nella planimetria.<\/li><li>Distinguete lo spazio a pavimento riservato dalle postazioni che dispongono di capacit\u00e0 di supporto effettivamente utilizzabile.<\/li><li>Prima dell\u2019installazione, esaminate il funzionamento normale, la manutenzione programmata e le condizioni di guasto da considerare.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a58e27 e-flex e-con-boxed e-con e-parent\" data-id=\"3a58e27\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c2960ed elementor-widget elementor-widget-text-editor\" data-id=\"c2960ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Definite i carichi dei rack e i vincoli del sito<\/h2><p class=\"p1\">Preparate un elenco dei rack prima di disegnare le file. Assegnate un identificativo a ciascun armadio e registratene le esigenze di spazio e di infrastrutture di supporto. Includete i rack di rete, archiviazione ed elaborazione, tenendo conto delle differenze nelle dimensioni, nella quantit\u00e0 di cavi e nell\u2019accesso.<\/p><p class=\"p1\">Raccogliete i seguenti dati:<\/p><ul><li class=\"translation-block\">Apparecchiature: numero di rack, <a href=\"https:\/\/www.eabel.com\/it\/spiegazione-delle-dimensioni-degli-armadi-rack-per-server-della-profondita-della-larghezza-e-dellaltezza\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>dimensioni esterne degli armadi<\/b><\/a>, peso installato, configurazione di spedizione e requisiti di accesso.<\/li><li>Fabbisogno elettrico: potenza di progetto per ogni rack, tensione di alimentazione, connessioni e risposta richiesta al guasto di una linea di alimentazione.<\/li><li class=\"translation-block\">Raffreddamento: direzione del flusso d\u2019aria delle apparecchiature, <a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/A23\/IP\/A23_Ch20\/a23_ch20_ip.aspx\" target=\"_blank\" rel=\"noopener noreferrer\"><b>condizioni operative richieste<\/b><\/a> ed eventuali interfacce per il raffreddamento a liquido.<\/li><li>Vincoli del sito: dimensioni misurate del locale, pilastri, altezza del soffitto, porte, limiti strutturali e impianti esistenti.<\/li><li>Installazione: occupazione iniziale, fasi successive, apparecchiature che devono rimanere operative e finestre disponibili per le modifiche.<\/li><\/ul><p class=\"p1\">Adottate una base coerente per i carichi elettrici. Un valore operativo misurato, un dato nominale di targa dell\u2019hardware e un valore di dimensionamento assunto in fase di progetto descrivono aspetti diversi. Indicate quale valore utilizzate e perch\u00e9. La somma dei carichi di progetto dei rack definisce il carico IT previsto, mentre la potenza totale assorbita dalla struttura comprende anche i sistemi di supporto e le perdite.<\/p><p class=\"p1\">Registrate separatamente i carichi iniziali e quelli successivi, segnalando le ipotesi non confermate. Aggiornate l\u2019elenco man mano che viene scelto l\u2019hardware: una variazione nella combinazione delle apparecchiature pu\u00f2 modificare le infrastrutture di supporto necessarie nella stessa postazione rack.<\/p><p class=\"p1\">Per un locale esistente, confrontate il disegno con l\u2019installazione reale. Una passerella portacavi non documentata, una porta modificata o una nuova unit\u00e0 di raffreddamento possono rendere inadeguata anche una planimetria ben ordinata. Segnalate le apparecchiature che non possono essere spostate e le aree che non possono essere messe fuori servizio.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-60283\" title=\"Configurazione simmetrica di quadri MT per centri dati\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use.webp\" alt=\"Configurazione simmetrica di quadri MT per centri dati\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use.webp 1880w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use-1536x1022.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Definite le zone del locale, gli accessi e gli ampliamenti<\/h2><h3>Assegnate le aree IT e di supporto<\/h3><p class=\"p1\">Delimitate l\u2019area dei rack, gli spazi per gli impianti elettrici e di raffreddamento, le aree di ingresso della rete o di permutazione e gli spazi per la ricezione o l\u2019approntamento delle apparecchiature. Un locale piccolo pu\u00f2 essere suddiviso in zone funzionali; le strutture pi\u00f9 grandi possono richiedere locali separati e controlli degli accessi.<\/p><p class=\"p1\">Collocate le apparecchiature di distribuzione e permutazione in modo da avere percorsi praticabili verso i rack serviti. Tenete gli imballaggi e le aree di approntamento temporaneo al di fuori dei percorsi di accesso alle aree operative.<\/p><p class=\"p1\">Includete nella planimetria di base i controlli delle porte, le uscite di emergenza e il coordinamento con la protezione antincendio. Le porte e le coperture dei sistemi di contenimento devono essere compatibili con il progetto approvato per la rivelazione e l\u2019estinzione degli incendi e per l\u2019esodo.<\/p><h3>Salvaguardate i percorsi di manutenzione e sostituzione<\/h3><p class=\"p1\">Tracciate i percorsi di consegna e sostituzione delle apparecchiature con dimensioni, pesi o esigenze di movimentazione critici. Controllate porte, svolte, ascensori, rampe e limiti di carico dei percorsi. Fate valutare al gruppo di progettazione strutturale i carichi concentrati sugli appoggi e quelli dovuti alla movimentazione su ruote, ove necessario; il solo carico medio sul pavimento non ne dimostra l\u2019idoneit\u00e0.<\/p><p class=\"p1 translation-block\">Distinguete la normale circolazione, lo spazio per la manutenzione delle apparecchiature e lo spazio di lavoro per gli interventi elettrici previsto dalle norme applicabili. Negli Stati Uniti, i <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.303\" target=\"_blank\" rel=\"noopener noreferrer\"><b>requisiti per gli spazi di lavoro elettrico<\/b><\/a> comprendono condizioni che vanno oltre l\u2019apertura della porta di un armadio, e lo spazio di lavoro richiesto non pu\u00f2 essere usato come deposito.<\/p><h3>Riservate zone per gli ampliamenti e i lavori<\/h3><p class=\"p1\">Indicate per le future postazioni rack lo stato delle infrastrutture: spazio riservato, interventi di supporto pianificati oppure postazione pronta per l\u2019installazione. Si evita cos\u00ec di considerare un ingombro a pavimento vuoto come capacit\u00e0 operativa disponibile.<\/p><p class=\"p1\">Indicate dove si svolgeranno i lavori successivi e come vi acceder\u00e0 il personale. In una struttura in esercizio, definite i confini di isolamento, le finestre di migrazione, il supporto temporaneo ove necessario e un piano di ripristino della configurazione precedente. Una futura fila che richieda di bloccare l\u2019unico percorso di sostituzione necessita di una diversa disposizione prima dell\u2019installazione iniziale.<\/p><p class=\"p1\">Collegate ogni fase di ampliamento agli interventi di supporto, come l\u2019estensione dei percorsi, l\u2019aggiunta di apparecchiature di distribuzione o la predisposizione dei collegamenti di raffreddamento. Assegnate responsabili e date di completamento, cos\u00ec che la fase successiva abbia un percorso definito verso l\u2019installazione.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-59334\" title=\"Rack di un centro dati con serratura a tastierino sull\u2019armadio\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock.webp\" alt=\"Rack di un centro dati con serratura a tastierino sull\u2019armadio\" width=\"500\" height=\"301\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock.webp 1986w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock-500x301.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock-1536x923.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Organizzate le file di rack e il sistema di raffreddamento<\/h2><h3>Adeguate la geometria dei rack alle esigenze di manutenzione<\/h3><p class=\"p1 translation-block\">Quando valutate prodotti come gli <a href=\"https:\/\/www.eabel.com\/it\/armadi-server-rack-2\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>armadi rack per server di E-abel<\/b><\/a>, confrontate le dimensioni esterne proposte, le posizioni delle guide e la disposizione degli ingressi cavi con l\u2019elenco delle apparecchiature. Includete gli accessori che sporgono nel corridoio; la larghezza interna di montaggio non determina l\u2019ingombro a pavimento dell\u2019armadio.<\/p><p class=\"p1\">Definite le dimensioni dei corridoi e degli spazi alle estremit\u00e0 delle file in base alle condizioni di accesso gi\u00e0 individuate. Considerate le porte aperte, le apparecchiature estraibili, i sistemi di gestione dei cavi, i dispositivi di alimentazione montati sul retro e gli eventuali mezzi di sollevamento necessari. Un rack che trova posto nel disegno deve anche consentire l\u2019intervento di manutenzione che richiede pi\u00f9 spazio. Per gli scambiatori di calore sulle porte posteriori e i raccordi dei tubi flessibili, verificate i rispettivi spazi necessari alla manutenzione anzich\u00e9 usare le dimensioni di una porta rack standard.<\/p><h3>Separate l\u2019aria di mandata da quella di espulsione<\/h3><p class=\"p1\">Per un flusso d\u2019aria dalla parte anteriore a quella posteriore, disponete i rack con i fronti contrapposti nei corridoi freddi e i retri contrapposti nei corridoi caldi. Allineate le bocchette di mandata e i percorsi di ripresa con questi corridoi e predisponete canalizzazioni o soluzioni adeguate negli armadi per il flusso d\u2019aria laterale.<\/p><p class=\"p1 translation-block\">Adottate <a href=\"https:\/\/www.energy.gov\/sites\/default\/files\/2024-07\/best-practice-guide-data-center-design_0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><b>misure di gestione dei flussi d\u2019aria<\/b><\/a>, come pannelli di chiusura e attraversamenti dei cavi sigillati, per limitare miscelazioni e dispersioni. Scegliete il contenimento del corridoio freddo o caldo in funzione del sistema di raffreddamento, della protezione antincendio e dell\u2019accesso per la manutenzione. Confrontate il fabbisogno di flusso d\u2019aria di ogni rack con la portata disponibile; la capacit\u00e0 di raffreddamento complessiva del locale non dimostra che il flusso d\u2019aria sia adeguato a ogni presa d\u2019aria.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-59077\" title=\"Grandi rack per server neri con ventilatori di raffreddamento in un centro dati 1024x786\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1.webp\" alt=\"Grandi rack per server neri con ventilatori di raffreddamento in un centro dati 1024x786\" width=\"500\" height=\"384\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1.webp 1024w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1-500x384.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Confrontate le soluzioni di pavimentazione<\/h3><p class=\"p1\">Entrambe le soluzioni di pavimentazione possono supportare sistemi compatibili di raffreddamento ad aria o a liquido. Verificate le condizioni strutturali e di distribuzione riportate di seguito.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Soluzione di layout<\/th><th>Implicazioni per il raffreddamento e i percorsi impiantistici<\/th><th>Verifiche prima della scelta definitiva<\/th><\/tr><\/thead><tbody><tr><td>Pavimento sopraelevato<\/td><td>Pu\u00f2 offrire un plenum d\u2019aria o uno spazio per le infrastrutture; restano possibili percorsi a soffitto<\/td><td>Soletta strutturale, pannelli e supporti del pavimento, carichi dovuti alla movimentazione su ruote, altezza libera del plenum, attraversamenti e accesso per la manutenzione<\/td><\/tr><tr><td>Assenza di pavimento sopraelevato<\/td><td>Utilizza altre soluzioni per la distribuzione dell\u2019aria e percorsi coordinati per gli impianti, spesso a soffitto<\/td><td>Carichi strutturali, altezza disponibile, supporti, accesso per la manutenzione e interferenze tra gli impianti a soffitto<\/td><\/tr><\/tbody><\/table><\/div><h3>Predisponete lo spazio per il raffreddamento a liquido<\/h3><p class=\"p1 translation-block\">Se l\u2019hardware richiede il raffreddamento a liquido, utilizzate le <a href=\"https:\/\/www.opencompute.org\/documents\/ocp-acf-reference-design-guidance-white-paper-r1-pdf\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>indicazioni per pianificare la distribuzione del liquido<\/b><\/a> per riservare spazio alle apparecchiature di raffreddamento scelte, compresa un\u2019unit\u00e0 di distribuzione del refrigerante, o CDU, ove richiesta. Considerate tubazioni, collettori, valvole, raccordi dei tubi flessibili, accesso per la manutenzione e i sistemi specificati per il rilevamento e il monitoraggio delle perdite.<\/p><p class=\"p1\">Seguite il percorso del calore oltre il rack. Una CDU liquido-aria situata nella sala dati cede calore all\u2019aria della sala, aumentando il carico del relativo sistema di raffreddamento ad aria. Una configurazione liquido-liquido trasferisce il calore a un altro circuito di raffreddamento. Nel pianificare l\u2019integrazione del raffreddamento a liquido, verificate sia il carico delle apparecchiature ancora raffreddate ad aria sia la capacit\u00e0 del sistema a liquido.<\/p><p class=\"p1\">Non esiste una soglia universale di potenza del rack che determini il metodo di raffreddamento per ogni progetto. Basate questa scelta sui requisiti dei fornitori dell\u2019hardware e dei sistemi di raffreddamento.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-54358\" title=\"Centri dati\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers.webp\" alt=\"Centri dati\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers.webp 1440w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Coordinate l\u2019alimentazione e i percorsi dei cavi<\/h2><h3>Verificate i percorsi A\/B e la capacit\u00e0 in caso di guasto<\/h3><p class=\"p1\">Tracciate il percorso dalla distribuzione a monte fino a ciascuna connessione rack. Distinguete le unit\u00e0 di distribuzione dell\u2019alimentazione a livello di impianto, o PDU, dalle PDU rack, che distribuiscono l\u2019alimentazione all\u2019interno di un armadio. I quadri di distribuzione remoti costituiscono un altro possibile punto di distribuzione dei circuiti derivati. Utilizzate lo schema elettrico unifilare del progetto, una rappresentazione semplificata dei collegamenti di alimentazione, per individuare la configurazione effettiva.<\/p><p class=\"p1\">Quando ciascuna delle due linee di alimentazione deve poter sostenere l\u2019intero carico IT, verificate la capacit\u00e0 utilizzabile lungo tutto il percorso rimasto in servizio, compresi circuiti, connessioni e PDU rack. Due percorsi da 150 kW non possono fornire piena ridondanza per un carico di 300 kW, anche se nessuno dei due \u00e8 sovraccarico durante la normale ripartizione del carico.<\/p><p class=\"p1\">Individuate le apparecchiature condivise a monte e i punti comuni dei percorsi o dei supporti, e confermate che l\u2019hardware IT possa continuare a funzionare dopo la perdita di una linea di alimentazione. Le etichette A\/B identificano i percorsi, ma non ne dimostrano l\u2019indipendenza n\u00e9 attestano una classificazione Tier.<\/p><p class=\"p1 translation-block\">Prevedete spazio per l\u2019utilizzo e la manutenzione di <a href=\"https:\/\/www.eabel.com\/it\/armadi-di-distribuzione-elettrica-per-data-center\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>armadi di distribuzione elettrica<\/b><\/a>, unit\u00e0 di derivazione dai condotti sbarre e dispositivi di commutazione che alimentano apparecchiature con un solo cavo di alimentazione. Un dispositivo di commutazione non rende ridondante l\u2019alimentatore dell\u2019apparecchiatura collegata. Verificate l\u2019accesso ai connettori e che i cavi arrivino ai punti di collegamento; la sola costruzione a innesto non autorizza l\u2019installazione o la rimozione sotto tensione.<\/p><p class=\"p1\">Nel disegno di un condotto sbarre a soffitto, rappresentate le unit\u00e0 di derivazione oltre all\u2019asse del condotto. Le loro dimensioni, le maniglie di manovra, la direzione dei cavi in uscita e l\u2019accesso per l\u2019installazione possono influire sullo spazio disponibile attorno a un rack. Verificate questi dettagli rispetto al sistema scelto prima di fissare le posizioni delle passerelle o dei sistemi di contenimento vicini.<\/p><h3>Coordinate i percorsi dati e gli impianti a soffitto<\/h3><p class=\"p1 translation-block\">Collocate le apparecchiature di permutazione e di rete in modo che i percorsi effettivi dei cavi rispettino i limiti e i requisiti di installazione dei mezzi trasmissivi scelti. Gli switch in cima al rack e quelli a fine fila comportano esigenze di instradamento diverse. Verificate i <a href=\"https:\/\/www.eabel.com\/it\/gestione-dei-cavi-nei-rack-dei-server\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>requisiti di gestione dei cavi<\/b><\/a>, compresi capacit\u00e0 delle passerelle, raggio di curvatura, supporto, etichettatura e accesso lungo ciascun percorso. Dove il progetto richiede connessioni con percorsi fisicamente separati, seguite entrambi i percorsi fino ai punti di distribuzione o di ingresso specificati e individuate ogni passerella, tubo protettivo o attraversamento condiviso che potrebbe vanificare tale separazione.<\/p><p class=\"p1\">Aggiungete una sezione verticale di una fila rappresentativa, indicando le quote di passerelle portacavi, condotti sbarre, tubazioni di raffreddamento, sistemi di contenimento, supporti, illuminazione e sistemi antincendio. Per gli involucri elettrici, indicate lo spazio per l\u2019ingresso dei cavi e l\u2019apertura dei pannelli, l\u2019accesso per l\u2019installazione e l\u2019eventuale spazio dedicato agli impianti elettrici previsto dalle norme applicabili. Verificate che sia possibile eseguire la manutenzione di ciascun impianto senza bloccare l\u2019accesso a un altro e includete i collegamenti di messa a terra richiesti.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-54567\" title=\"Centri dati\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1.webp\" alt=\"Centri dati\" width=\"500\" height=\"316\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1.webp 570w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1-500x316.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Esempio: layout di un centro dati con 20 rack<\/h2><p class=\"p1\">Considerate un esempio didattico con due file di dieci rack rivolte verso un corridoio freddo comune. Supponete che ciascun armadio sia largo 0.6 m e profondo 1.2 m, senza spazi aggiuntivi tra armadi adiacenti. Assegnate 1.2 m al corridoio centrale, a ciascun corridoio posteriore esterno e a ciascuna estremit\u00e0 delle file. Si tratta di ipotesi di calcolo, non di spazi di manutenzione approvati n\u00e9 di minimi normativi.<\/p><p class=\"p1\">La lunghezza di base della fila \u00e8 10 \u00d7 0.6 + 2 \u00d7 1.2 = 8.4 m. Trasversalmente alle file, la profondit\u00e0 \u00e8 2 \u00d7 1.2 + 3 \u00d7 1.2 = 6.0 m. Il blocco risultante, composto da rack e corridoi, occupa 50.4 m\u00b2, pari a circa 543 ft\u00b2.<\/p><p class=\"p1\">Assegnate ora agli armadi carichi di progetto diversi:<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Gruppo di rack<\/th><th>Numero di rack<\/th><th>Carico di progetto per rack<\/th><th>Carico IT del gruppo<\/th><\/tr><\/thead><tbody><tr><td>Gruppo a carico standard<\/td><td>16<\/td><td>8 kW<\/td><td>128 kW<\/td><\/tr><tr><td>Gruppo a carico pi\u00f9 elevato<\/td><td>4<\/td><td>28 kW<\/td><td>112 kW<\/td><\/tr><tr><td>Totale<\/td><td>20<\/td><td>\u2014<\/td><td>240 kW<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">La media \u00e8 di 12 kW per rack, ma i quattro armadi da 28 kW rappresentano circa il 47% del carico IT. Supponete ora che ogni fila disponga di 140 kW di capacit\u00e0 elettrica utilizzabile nelle condizioni in esame. Collocare tutti e quattro gli armadi a carico pi\u00f9 elevato insieme a sei armadi da 8 kW crea una fila da 160 kW, lasciando l\u2019altra a 80 kW. La capacit\u00e0 combinata \u00e8 di 280 kW, ma la prima fila supera il proprio limite.<\/p><p class=\"p1\">Collocate invece in ogni fila due armadi da 28 kW e otto da 8 kW: ogni fila totalizza cos\u00ec 120 kW. Questa disposizione supera la verifica elettrica ipotizzata a livello di fila. I singoli circuiti e il raffreddamento locale richiedono comunque una convalida. Raggruppare i rack a carico elevato resta una scelta valida quando sono supportati da infrastrutture dedicate; distribuirli non \u00e8 una regola universale.<\/p><p class=\"p1\">Aggiungete spazi separati per le apparecchiature elettriche e di raffreddamento, l\u2019ingresso della rete, l\u2019approntamento e gli ampliamenti. Ricontrollate le dimensioni ipotizzate dei corridoi rispetto alle porte effettive, agli attrezzi di manutenzione e alla sostituzione delle apparecchiature. Il blocco calcolato \u00e8 solo una parte del locale.<\/p><p class=\"p1\">Il totale di 240 kW \u00e8 un carico IT di progetto. La scelta di un gruppo di continuit\u00e0, o UPS, dei circuiti derivati e delle apparecchiature di raffreddamento richiede calcoli separati per le condizioni operative e di resilienza del progetto.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-45428\" title=\"Tecnici che installano server in rack aperti in un centro dati\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/10\/Technicians-installing-servers-into-open-racks-in-a-data-center.webp\" alt=\"Tecnici che installano server in rack aperti in un centro dati\" width=\"500\" height=\"418\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/10\/Technicians-installing-servers-into-open-racks-in-a-data-center.webp 674w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/10\/Technicians-installing-servers-into-open-racks-in-a-data-center-14x12.webp 14w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Convalidate il layout prima dell\u2019installazione<\/h2><h3>Verificate il funzionamento normale e le condizioni locali<\/h3><p class=\"p1\">Sovrapponete i disegni architettonici, strutturali, elettrici, meccanici, di rete e antincendio. Verificate che le posizioni delle apparecchiature e le quote dei percorsi coincidano nei diversi elaborati. Confrontate i carichi locali dei rack con la capacit\u00e0 assegnata alle rispettive connessioni e zone di raffreddamento.<\/p><p class=\"p1\">Misurate le condizioni dell\u2019aria in ingresso in punti rappresentativi delle apparecchiature, anzich\u00e9 affidarvi a un\u2019unica lettura media del locale. Includete le posizioni e le altezze in cui il progetto prevede variazioni significative. Le aree raffreddate a liquido necessitano del monitoraggio specificato per i rispettivi circuiti del refrigerante e per i relativi rischi di perdita.<\/p><p class=\"p1\">Per le apparecchiature raffreddate ad aria, distinguete l\u2019intervallo operativo raccomandato dai limiti ammissibili, pi\u00f9 ampi. Durante il normale funzionamento, puntate all\u2019intervallo raccomandato applicabile; il solo rispetto dei limiti ammissibili non definisce un obiettivo adeguato a lungo termine. Confermate la classe dell\u2019apparecchiatura e le specifiche del produttore anzich\u00e9 applicare lo stesso intervallo di temperatura a ogni rack. Impostate le soglie di monitoraggio in base a tali requisiti.<\/p><p class=\"p1\">Utilizzate la fluidodinamica computazionale, o CFD, quando \u00e8 necessaria un\u2019analisi dei flussi d\u2019aria. Registrate i carichi delle apparecchiature, la geometria e le condizioni di raffreddamento ipotizzati, affinch\u00e9 il modello possa essere esaminato e successivamente confrontato con le misurazioni sul campo.<\/p><h3>Esaminate la manutenzione e le condizioni di guasto da considerare<\/h3><p class=\"p1\">Simulate le operazioni di sostituzione che richiedono pi\u00f9 spazio o mezzi di movimentazione. Includete i mezzi di sollevamento e un\u2019area designata per l\u2019appoggio temporaneo dei componenti rimossi, mantenendo liberi gli spazi di lavoro elettrico e le vie di esodo e preservando al tempo stesso le condizioni operative richieste.<\/p><p class=\"p1\">Esaminate uno scenario in cui i server rimangono alimentati dall\u2019UPS, mentre il raffreddamento essenziale perde alimentazione o portata. Individuate i requisiti di alimentazione di riserva e riavvio di pompe, ventilatori, controlli ed eventuali CDU, comprese le apparecchiature condivise che servono pi\u00f9 rack. Fate determinare al gruppo di ingegneria per quanto tempo le apparecchiature IT possano operare entro i propri limiti dopo l\u2019interruzione del raffreddamento. Verificate che il ripristino previsto o l\u2019arresto controllato rientrino in tale tempo di autonomia termica; la sola alimentazione elettrica di riserva non dimostra la possibilit\u00e0 di continuare a funzionare.<\/p><p class=\"p1 translation-block\">Fate verificare ai gruppi di ingegneria e messa in servizio gli scenari di alimentazione e raffreddamento richiesti. Per i progetti che mirano alla certificazione Tier, utilizzate le <a href=\"https:\/\/uptimeinstitute.com\/tiers\" target=\"_blank\" rel=\"noopener noreferrer\"><b>indicazioni sulla classificazione Tier<\/b><\/a> per comprendere il livello previsto, quindi verificate il progetto rispetto allo standard Tier applicabile. Definite criteri di accettazione misurabili: condizioni all\u2019ingresso delle apparecchiature, carico consentito sui circuiti, accesso richiesto e continuit\u00e0 di servizio specificata. Le prove sui sistemi in esercizio richiedono personale qualificato che operi secondo un piano approvato con procedure di ripristino.<\/p><p class=\"p1\">Registrate gli scostamenti e risolveteli in conformit\u00e0 ai requisiti di progetto. Conservate i risultati delle verifiche di accettazione come riferimento per le modifiche successive.<\/p><h3>Completate la documentazione operativa<\/h3><p class=\"p1 translation-block\">Aggiornate la planimetria in modo che corrisponda alle apparecchiature installate e mantenetela coerente con le attivit\u00e0 ordinarie di <a href=\"https:\/\/www.eabel.com\/it\/lista-di-controllo-per-la-manutenzione-dei-rack-dei-server-nei-data-center\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>manutenzione dei rack per server<\/b><\/a>. Collegate gli identificativi dei rack a circuiti, percorsi dei cavi, zone di raffreddamento e punti di monitoraggio. Il software di gestione delle infrastrutture del centro dati pu\u00f2 mantenere queste relazioni, ma la documentazione necessita comunque di un responsabile e di un processo di gestione delle modifiche.<\/p><p class=\"p1\">Richiedete una revisione del layout quando uno spostamento o un\u2019aggiunta modifica il carico, i flussi d\u2019aria, i percorsi o l\u2019accesso. Il disegno approvato dovrebbe restare utile dopo la prima installazione.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-43686\" title=\"File di server di rete e cavi in un centro dati\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/07\/Rows-of-network-servers-and-cables-in-a-data-center.webp\" alt=\"File di server di rete e cavi in un centro dati\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/07\/Rows-of-network-servers-and-cables-in-a-data-center.webp 1023w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/07\/Rows-of-network-servers-and-cables-in-a-data-center-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Domande frequenti sul layout dei centri dati<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f609b71 elementor-widget elementor-widget-n-accordion\" data-id=\"f609b71\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Pannello a fisarmonica. Aprire i collegamenti con Invio o Spazio, chiudere con Esc e spostarsi con i tasti freccia\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2570\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2570\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Come confrontare le proposte di layout per un centro dati? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2570\" class=\"elementor-element elementor-element-293a2c7 e-con-full e-flex e-con e-child\" data-id=\"293a2c7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-124dfda elementor-widget elementor-widget-text-editor\" data-id=\"124dfda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Confrontate le proposte usando lo stesso elenco delle apparecchiature, gli stessi carichi dei rack e gli stessi requisiti operativi. Chiedete a ogni progettista di indicare la capacit\u00e0 utilizzabile dei rack, lo spazio per le apparecchiature di supporto, l\u2019accesso per la manutenzione e le predisposizioni per gli ampliamenti. Confrontate i costi a parit\u00e0 di perimetro, includendo le infrastrutture necessarie a rendere operativa ciascuna postazione rack.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2571\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2571\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00c8 possibile riutilizzare i rack per server esistenti in un nuovo layout del centro dati? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2571\" class=\"elementor-element elementor-element-ea03441 e-con-full e-flex e-con e-child\" data-id=\"ea03441\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-19659e3 elementor-widget elementor-widget-text-editor\" data-id=\"19659e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ec, se le dimensioni, le guide di montaggio, le portate nominali e lo stato di conservazione sono adatti alle apparecchiature previste. Verificate i flussi d\u2019aria, lo spazio per i cavi e la compatibilit\u00e0 degli accessori prima di mantenerli nel progetto. Riutilizzare un armadio consente un risparmio solo se le modifiche e i lavori di installazione necessari restano praticabili.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2572\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2572\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00c8 meglio scegliere armadi rack per server larghi 600 mm o 800 mm? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2572\" class=\"elementor-element elementor-element-860dd59 e-con-full e-flex e-con e-child\" data-id=\"860dd59\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6df9e9c elementor-widget elementor-widget-text-editor\" data-id=\"6df9e9c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un armadio da 600 mm mantiene compatta la fila. Un armadio da 800 mm pu\u00f2 offrire pi\u00f9 spazio laterale per la gestione dei cavi e le PDU rack verticali. Verificate lo spazio utilizzabile nel modello scelto con le vostre apparecchiature installate; la sola larghezza esterna non conferma lo spazio libero disponibile.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2573\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2573\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Che cosa dovrebbe includere un preventivo per armadi rack per server? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2573\" class=\"elementor-element elementor-element-ae29b49 e-con-full e-flex e-con e-child\" data-id=\"ae29b49\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5da3c39 elementor-widget elementor-widget-text-editor\" data-id=\"5da3c39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Richiedete le dimensioni esatte, la profondit\u00e0 di montaggio, le portate nominali, i disegni e gli accessori inclusi. Verificate se porte, pannelli laterali, sistemi di gestione dei cavi, pannelli di chiusura e PDU rack sono inclusi o quotati separatamente. Chiarite anche la configurazione di consegna e chi si occupa dell\u2019installazione.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2574\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2574\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quando servono armadi rack per server personalizzati? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2574\" class=\"elementor-element elementor-element-5d4d6ed e-con-full e-flex e-con e-child\" data-id=\"5d4d6ed\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7fd32f6 elementor-widget elementor-widget-text-editor\" data-id=\"7fd32f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Valutate la personalizzazione quando gli armadi standard non possono soddisfare requisiti verificati di montaggio, ingresso cavi, spazio o manutenzione. Prima di decidere, confrontate la soluzione personalizzata con una modifica del layout. Confermate la portata nominale della configurazione finale e i requisiti di conformit\u00e0 applicabili, anzich\u00e9 basarvi sulle specifiche di un modello standard.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2575\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2575\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Chi dovrebbe approvare il layout di un centro dati prima dell\u2019ordine delle apparecchiature? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2575\" class=\"elementor-element elementor-element-3b8f695 e-con-full e-flex e-con e-child\" data-id=\"3b8f695\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b89148 elementor-widget elementor-widget-text-editor\" data-id=\"3b89148\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Il committente dovrebbe coordinare l\u2019approvazione con i gruppi responsabili dei requisiti elettrici, di raffreddamento, strutturali e antincendio. Il fornitore degli armadi dovrebbe confermare le dimensioni delle apparecchiature, i dettagli di montaggio e gli ingressi cavi. Tenete distinta l\u2019approvazione dei disegni degli armadi da quella del layout dell\u2019intera struttura.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f550e7 elementor-widget elementor-widget-text-editor\" data-id=\"2f550e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusione<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-42680\" title=\"Centro dati moderno con rack per server e display LED blu\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/06\/Modern-data-center-with-server-racks-and-blue-LED-displays.webp\" alt=\"Centro dati moderno con rack per server e display LED blu\" width=\"500\" height=\"312\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/06\/Modern-data-center-with-server-racks-and-blue-LED-displays.webp 1250w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/06\/Modern-data-center-with-server-racks-and-blue-LED-displays-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><p class=\"p1\">Un buon layout di centro dati assegna a ogni rack una postazione dotata del necessario supporto: una posizione fisica, una connessione elettrica adeguata, un percorso di raffreddamento e un accesso praticabile. La pianificazione risulta pi\u00f9 solida quando questi requisiti vengono esaminati insieme e verificati rispetto alle attivit\u00e0 che gli operatori svolgeranno effettivamente. Un disegno chiaro con ipotesi esplicite facilita la valutazione delle scelte delle apparecchiature e delle modifiche successive.<\/p><p class=\"p1 translation-block\">Prima di richiedere proposte per le apparecchiature, definite i carichi previsti dei rack, le dimensioni disponibili, le fasi di installazione e le condizioni operative richieste. In questo modo i fornitori dispongono di una base utile per verificare l\u2019inserimento e chiarire le interfacce. <a href=\"https:\/\/www.eabel.com\/it\/contatto\/\" target=\"_blank\" rel=\"noopener\"><strong>Contattate E-abel<\/strong><\/a> con la planimetria, l\u2019elenco dei rack, i parametri di alimentazione e i requisiti degli involucri per discutere le configurazioni adatte di rack e armadi elettrici. Condividere tempestivamente questi dettagli aiuta a individuare le questioni relative a ingresso cavi, montaggio e spazio per la manutenzione prima di ordinare le apparecchiature.<\/p><h2 class=\"translation-block\"><b>Letture correlate<\/b><\/h2><p><a href=\"https:\/\/www.eabel.com\/it\/selezionando-il-giusto-armadio-rack-per-data-center\/\" target=\"_blank\" rel=\"noopener noreferrer\">Come scegliere un armadio rack per il vostro centro dati<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/it\/sigillare-gli-spazi-vuoti-nei-rack-dei-server\/\" target=\"_blank\" rel=\"noopener noreferrer\">Sigillare gli spazi vuoti nei rack per server per migliorare i flussi d\u2019aria<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/it\/selezionando-la-pdu-giusta-per-gli-armadi-del-data-center\/\" target=\"_blank\" rel=\"noopener noreferrer\">Come scegliere la PDU giusta per il vostro centro dati<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/it\/quadro-distribuzione-remoto-data-center\/\" target=\"_blank\" rel=\"noopener noreferrer\">Che cos\u2019\u00e8 un quadro di distribuzione remoto in un centro dati?<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/it\/rack-per-server-modulari-per-data-center\/\" target=\"_blank\" rel=\"noopener noreferrer\">Rack modulari per server per centri dati scalabili<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/it\/electrical-cabinets-modular-data-centers\/\" target=\"_blank\" rel=\"noopener noreferrer\">Armadi elettrici per centri dati modulari<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Progettate il layout di un centro dati con indicazioni pratiche su disposizione dei rack, raffreddamento, alimentazione, cablaggio, accesso per la manutenzione e ampliamenti futuri.<\/p>","protected":false},"author":17,"featured_media":71796,"comment_status":"open","ping_status":"open","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[80],"tags":[],"class_list":["post-71772","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.6.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"Jie Lian\"\/>\n\t<meta name=\"google-site-verification\" content=\"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.eabel.com\/it\/data-center-layout\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.6.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"E-Abel -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Data Center Layout: Guide and Best Practices - E-Abel\" \/>\n\t\t<meta property=\"og:description\" content=\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.eabel.com\/it\/data-center-layout\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-25T06:47:06+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-25T06:47:09+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Data Center Layout: Guide and Best Practices - E-Abel\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#blogposting\",\"name\":\"Data Center Layout: Guide and Best Practices - E-Abel\",\"headline\":\"Data Center Layout: Guide and Best Practices\",\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/author\\\/jay\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Data-center-layout-with-two-rows-of-server-racks.webp\",\"width\":1448,\"height\":1086,\"caption\":\"Data center layout with two rows of server racks\"},\"datePublished\":\"2026-11-25T06:47:06+00:00\",\"dateModified\":\"2026-11-25T06:47:09+00:00\",\"inLanguage\":\"it-IT\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/#listItem\",\"position\":1,\"name\":\"E-able\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#listItem\",\"name\":\"Data Center Layout: Guide and Best Practices\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/#listItem\",\"name\":\"E-able\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#listItem\",\"position\":3,\"name\":\"Data Center Layout: Guide and Best Practices\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/#organization\",\"name\":\"E-Abel\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/\",\"telephone\":\"+8618860978683\",\"foundingDate\":\"2008-08-28\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"value\":150},\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/043b221a8891a285b2aaa66333022ef.png\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#organizationLogo\",\"width\":2560,\"height\":1301,\"caption\":\"E-Abel logo form\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/author\\\/jay\\\/#author\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/author\\\/jay\\\/\",\"name\":\"Jie Lian\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Jie Lian\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#webpage\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/\",\"name\":\"Data Center Layout: Guide and Best Practices - E-Abel\",\"description\":\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\",\"inLanguage\":\"it-IT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/author\\\/jay\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/author\\\/jay\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Data-center-layout-with-two-rows-of-server-racks.webp\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#mainImage\",\"width\":1448,\"height\":1086,\"caption\":\"Data center layout with two rows of server racks\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/data-center-layout\\\/#mainImage\"},\"datePublished\":\"2026-11-25T06:47:06+00:00\",\"dateModified\":\"2026-11-25T06:47:09+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/\",\"name\":\"E-Abel\",\"inLanguage\":\"it-IT\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/it\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Data Center Layout: Guide and Best Practices - E-Abel<\/title>\n\n","aioseo_head_json":{"title":"Progettazione del layout di un centro dati: guida e buone pratiche - E-Abel","description":"Progettate il layout di un centro dati con indicazioni pratiche su disposizione dei rack, raffreddamento, alimentazione, cablaggio, accesso per la manutenzione e ampliamenti futuri.","canonical_url":"https:\/\/www.eabel.com\/it\/data-center-layout\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"google-site-verification":"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#blogposting","name":"Data Center Layout: Guide and Best Practices - E-Abel","headline":"Data Center Layout: Guide and Best Practices","author":{"@id":"https:\/\/www.eabel.com\/it\/author\/jay\/#author"},"publisher":{"@id":"https:\/\/www.eabel.com\/it\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","width":1448,"height":1086,"caption":"Data center layout with two rows of server racks"},"datePublished":"2026-11-25T06:47:06+00:00","dateModified":"2026-11-25T06:47:09+00:00","inLanguage":"it-IT","mainEntityOfPage":{"@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#webpage"},"isPartOf":{"@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/it\/#listItem","position":1,"name":"E-able","item":"https:\/\/www.eabel.com\/it\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/it\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/it\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/www.eabel.com\/it\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#listItem","name":"Data Center Layout: Guide and Best Practices"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/it\/#listItem","name":"E-able"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#listItem","position":3,"name":"Data Center Layout: Guide and Best Practices","previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/it\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/www.eabel.com\/it\/#organization","name":"E-Abel","url":"https:\/\/www.eabel.com\/it\/","telephone":"+8618860978683","foundingDate":"2008-08-28","numberOfEmployees":{"@type":"QuantitativeValue","value":150},"logo":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2022\/05\/043b221a8891a285b2aaa66333022ef.png","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#organizationLogo","width":2560,"height":1301,"caption":"E-Abel logo form"},"image":{"@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.eabel.com\/it\/author\/jay\/#author","url":"https:\/\/www.eabel.com\/it\/author\/jay\/","name":"Jie Lian","image":{"@type":"ImageObject","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g","width":96,"height":96,"caption":"Jie Lian"}},{"@type":"WebPage","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#webpage","url":"https:\/\/www.eabel.com\/it\/data-center-layout\/","name":"Data Center Layout: Guide and Best Practices - E-Abel","description":"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.","inLanguage":"it-IT","isPartOf":{"@id":"https:\/\/www.eabel.com\/it\/#website"},"breadcrumb":{"@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#breadcrumblist"},"author":{"@id":"https:\/\/www.eabel.com\/it\/author\/jay\/#author"},"creator":{"@id":"https:\/\/www.eabel.com\/it\/author\/jay\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#mainImage","width":1448,"height":1086,"caption":"Data center layout with two rows of server racks"},"primaryImageOfPage":{"@id":"https:\/\/www.eabel.com\/it\/data-center-layout\/#mainImage"},"datePublished":"2026-11-25T06:47:06+00:00","dateModified":"2026-11-25T06:47:09+00:00"},{"@type":"WebSite","@id":"https:\/\/www.eabel.com\/it\/#website","url":"https:\/\/www.eabel.com\/it\/","name":"E-Abel","inLanguage":"it-IT","publisher":{"@id":"https:\/\/www.eabel.com\/it\/#organization"}}]},"og:locale":"it_IT","og:site_name":"E-Abel -","og:type":"article","og:title":"Data Center Layout: Guide and Best Practices - E-Abel","og:description":"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.","og:url":"https:\/\/www.eabel.com\/it\/data-center-layout\/","og:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","og:image:secure_url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","og:image:width":1448,"og:image:height":1086,"article:published_time":"2026-11-25T06:47:06+00:00","article:modified_time":"2026-11-25T06:47:09+00:00","twitter:card":"summary_large_image","twitter:title":"Data Center Layout: Guide and Best Practices - E-Abel","twitter:description":"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.","twitter:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp"},"aioseo_meta_data":{"post_id":"71772","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":false,"robots_noindex":true,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-11-25 06:47:28","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-11-25 02:59:34","updated":"2026-11-25 06:52:45","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/it\/\" title=\"E-able\">E-able<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/it\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tData Center Layout: Guide and Best Practices\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"E-able","link":"https:\/\/www.eabel.com\/it\/"},{"label":"Blog","link":"https:\/\/www.eabel.com\/it\/category\/blog\/"},{"label":"Data Center Layout: Guide and Best Practices","link":"https:\/\/www.eabel.com\/it\/data-center-layout\/"}],"_links":{"self":[{"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/posts\/71772","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/comments?post=71772"}],"version-history":[{"count":0,"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/posts\/71772\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/media\/71796"}],"wp:attachment":[{"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/media?parent=71772"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/categories?post=71772"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eabel.com\/it\/wp-json\/wp\/v2\/tags?post=71772"}],"curies":[{"name":"scrivere","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}