IP68 Waterproof Rating: What It Really Means

Learn what IP68 means, why depth and duration vary, what it does not cover, and what to verify before buying an IP68 enclosure.

Table of Contents

An IP68 waterproof rating means an enclosure is dust-tight and protected against continuous water immersion under specified conditions. It does not mean every IP68 product can stay underwater forever, work at any depth, or withstand every type of water exposure.

For a buyer, the label is only the starting point. The useful questions are: At what depth or pressure was the product tested, for how long, and in what assembled configuration? Those details determine whether an IP68 enclosure fits the real application.

Key Takeaways

  • The first digit, 6, means the enclosure is dust-tight.
  • The second digit, 8, covers continuous immersion under product-specific test conditions.
  • IP68 has no single depth or time limit that applies to every product.
  • The installed assembly—not the empty box alone—must provide the required protection.

What IP68 Means Under IEC 60529

IP68 rating infographic for dust and water protection

IP ratings come from IEC 60529, the international standard for classifying how enclosures protect electrical equipment against access, solid foreign objects, and harmful water ingress. The code provides a common test-based language, but it does not describe every type of durability or safety.

How to Read the 6 and 8

The first digit, 6, is the highest solid-particle protection level in the IP code. It identifies a dust-tight enclosure and protection against access to hazardous internal parts with the relevant probe.

The second digit, 8, identifies protection against continuous immersion under conditions specified for the product. The rating is therefore conditional: the 8 alone does not state a universal depth or duration.

IP68 vs IPX8

IP68 and IPX8 share the same water numeral. In IP68, the 6 confirms dust-tight protection. In IPX8, the X means no solid-particle grade is declared in that code; it does not mean the product has zero dust protection.

An IP68 product is therefore more informative about dust, but it does not automatically have a tougher immersion rating than every IPX8 product. The declared water-test conditions still control the comparison. For the wider code system, see this IP rating guide.

IP68 Depth, Duration, and Test Conditions

There is no universal IP68 depth or duration. One IP68 device may be declared for 1.5 meters and 30 minutes, while another may be tested at 10 meters or under a different combination of pressure and time.

IPX7 uses a defined temporary-immersion test. For IPX8, unless a relevant product standard sets the test, the manufacturer and user agree on conditions that must be more severe than IPX7 and account for continuous immersion in actual use. Therefore, neither “deeper than one meter” nor “more than 30 minutes” is a universal IP68 definition; the declared depth or pressure, duration, and configuration control the claim.

Greater depth increases hydrostatic pressure across doors, gaskets, cable entries, and other seals. Duration matters because small sealing defects, material movement, and pressure equalization can take time to affect the enclosure. Repeated pressure cycles may also create a different challenge from one static immersion test.

Useful documentation should identify the test depth or pressure, duration, enclosure orientation, sample configuration, whether ports were open or sealed, and the acceptance criteria. It should also state relevant water-temperature, liquid, and operating restrictions. UL Solutions includes IPX8 among its water-ingress tests to IEC/EN 60529, but buyers must still request the exact conditions and acceptance criteria used for the tested product.

The acceptance principle is protection against water entering in a quantity that causes harmful effects. Depending on the equipment and applicable criteria, a passing result does not always mean zero detectable moisture. It means the enclosure met the acceptance requirements under the stated conditions.

Buyer’s rule: Two products with the same IP68 label are not interchangeable. Compare their declared test conditions with the intended application.

IP68 rating chart showing dust and water resistance levels

IP68 vs IP66, IP67, IP69, and IP69K

These ratings address different water hazards. The right choice follows the exposure at the site, not the largest number on a datasheet.

Rating Tested Water Exposure What It Does Not Automatically Prove Best-Fit Use
IP66 Powerful water jets Immersion protection Outdoor spray, storms, and forceful hose exposure
IP67 Temporary immersion under defined conditions Powerful jets or continuous immersion Accidental or short-term submersion
IP68 Continuous immersion under product-specific conditions Powerful jets, hot washdown, or unlimited immersion Longer or application-specific immersion
IP69 High-pressure, high-temperature water jets under IEC 60529 Continuous immersion Industrial equipment exposed to hot, close-range washdown
IP6K9K (often called IP69K) High-pressure, high-temperature water jets under ISO 20653:2023 Continuous immersion or compliance with IEC 60529 Road-vehicle electrical equipment

IP68 does not automatically include the IP66 jet test. Immersion and water jets load seals in different ways, so a site exposed to both hazards needs evidence for both. A dual marking such as IP66/IP68, or documentation showing both tests, is more useful than assuming the higher numeral covers everything. For applications involving hot, high-pressure washdown, this IP68 vs IP69 comparison explains the difference in greater detail.

What IP68 Does Not Prove in Real Use

Static Immersion Is Not Every Water Hazard

An immersion test does not automatically cover pressure washers, fast-moving water, waves, or hot sanitation cleaning. These exposures can direct concentrated force at gasket edges, hinges, cable glands, and control interfaces.

Rapid changes in depth or temperature can also change the pressure across a seal. Equipment that moves repeatedly between air and water may face pressure cycling that a single test does not represent. Where these conditions matter, specify them separately and request matching evidence instead of relying on IP68 alone.

Materials, Corrosion, Aging, and Condensation

The IP code does not rate corrosion resistance, chemical compatibility, UV life, impact strength, or gasket service life. Passing a clean-water immersion test does not establish resistance to saltwater, chlorinated water, oils, detergents, or process chemicals unless those conditions were included in the evaluation.

Material and seal selection must match the environment. Stainless steel grade, coating condition, plastic formulation, and gasket compound can all affect long-term performance. Sunlight, heat, cold, vibration, impact, and repeated opening can weaken a seal even when the enclosure met IP68 when new.

Condensation is another separate problem. Moist air already inside an enclosure can condense when the internal surface falls below the dew point. Water may therefore appear inside without a direct leak. Venting, heating, drainage, and humidity control must be designed without weakening the required enclosure protection.

Underwater Operation and Other Approvals

IP68 does not prove that equipment can be energized, operated, or controlled underwater. The test state and intended operating state must match. A control box that survives immersion while switched off is not automatically approved for live underwater use.

The rating also does not establish electrical safety, fire performance, impact resistance, or suitability for a hazardous location. UL certification, an IK impact rating, ATEX conformity, and IECEx certification address different requirements and must be specified separately when the application calls for them.

IP68 is not the same as NEMA Type 6P. North American enclosure types can include requirements that the IP code does not express, including corrosion-related provisions for certain types. The current ANSI/NEMA EN 10250-2024 enclosure standard has a different scope and set of requirements from IEC 60529, so an IP68 label alone cannot establish Type 6P compliance. A fuller NEMA vs IP enclosure guide covers this distinction.

IP68 rings

How to Specify, Install, and Maintain an IP68 Enclosure

“IP68 required” is not a complete purchase specification. Define the real exposure first, then verify that the evidence applies to the enclosure as it will be supplied and installed.

Before Ordering

  1. Identify the applicable standard. State IEC 60529, its applicable edition, and any product-specific standard or customer requirement.
  2. Define the depth or pressure. Use the worst credible immersion level, including flood level or installed water depth, with a suitable project margin.
  3. Set the duration and exposure pattern. Distinguish one accidental event from long-term, repeated, or permanent installation underwater.
  4. Describe the liquid and temperature. Identify fresh water, saltwater, chlorinated water, oil, cleaning chemicals, temperature range, and any rapid temperature changes.
  5. Fix the test configuration. Confirm the exact model, size, mounting orientation, cover and port state, cable sizes, and whether the equipment is energized.
  6. Include the complete assembly. Account for glands, connectors, vents, windows, pushbuttons, locks, hinges, plugs, and mounting hardware.
  7. Request useful evidence. Review the declaration, datasheet, and test report; do not assume the IP marking proves third-party certification. If independent testing is required, confirm that the laboratory is accredited to ISO/IEC 17025 and that its accredited scope covers the relevant IEC 60529 tests.
  8. Control custom changes. Establish whether machining, accessory substitutions, coating changes, or production revisions require design review or retesting.

A practical specification can read: “IP68 to IEC 60529, tested at [depth or pressure] for [duration], in the specified orientation and complete installed configuration, including all cable entries and accessories.” This is a purchasing template, not mandatory wording from the standard.

Buyers comparing standard and customized designs can review Eabel’s electrical enclosures and discuss the required immersion conditions, material, dimensions, openings, and accessories before selecting a configuration.

The Complete Assembly Determines Protection

The rating of an empty box does not automatically transfer to a finished control enclosure. Likewise, combining an IP68 enclosure with separately rated cable glands does not prove that the complete assembly meets IP68. Hole tolerances, cable diameter, sealing washers, thread engagement, gland torque, door alignment, and gasket compression all affect the result.

The strongest evidence covers the actual assembly or a clearly defined configuration family. If a tested design cannot be supplied unchanged, the manufacturer or project engineer should review whether the difference is covered by existing evidence or needs additional verification.

After Installation or Modification

Install glands and fasteners to the specified torque, keep sealing surfaces clean, and check that the gasket remains continuous and evenly compressed. Unused openings need suitable plugs, and cables should not pull sideways on their glands. This guide to sealing an electrical enclosure explains the main leakage paths.

Field drilling, added controls, replacement connectors, damaged coatings, a changed mounting direction, or a repaired gasket can move the enclosure outside its tested configuration. Inspect the seal after installation and maintenance, and set an inspection interval that matches the exposure and consequence of failure.

Maintaining IP68 is therefore a configuration-control task, not a one-time product purchase. The rating remains meaningful only while the tested sealing system is preserved.

Metal enclosure submerged underwater illustrating IP68 rating

FAQs About IP68 Waterproof Ratings

How deep and how long can an IP68 enclosure stay underwater?

IP68 has no universal depth or time limit. Check the tested depth or pressure, duration, orientation, and assembled configuration stated by the manufacturer.

Not automatically. IP68 addresses water ingress under specified test conditions, not corrosion or chemical compatibility. Confirm the enclosure material, coating, gasket, and accessories suit the actual liquid.

No. IP66 tests powerful water jets, while IP68 tests immersion. If the enclosure faces both hazards, request an IP66/IP68 rating or evidence that it passed both tests.

No. The finished assembly must maintain the rating. Cable diameter, hole size, sealing washers, gland torque, plugs, windows, and other accessories can affect water resistance.

No. The two systems use different requirements and test methods. An IP68 rating alone does not prove that an enclosure complies with NEMA Type 6P.

Request a datasheet or test report stating the applicable standard, exact model, depth or pressure, duration, orientation, port condition, operating state, and acceptance criteria. For independent testing, verify the laboratory’s accreditation scope covers the relevant IEC 60529 tests.

Conclusion

Open metal electrical enclosure for indoor installations

IP68 is the right rating when continuous immersion is the real hazard and the required conditions are clearly defined. It describes dust-tight protection and immersion resistance within a stated test envelope—not unlimited waterproofing, jet resistance, corrosion resistance, or automatic underwater operation.

If you need an IP68 electrical enclosure, contact Eabel with the required depth, immersion time, enclosure size, material, liquid exposure, installation method, and custom openings. These details will help the team assess an appropriate enclosure configuration for your project.

Related Reading

IP65 vs IP66 vs IP67: Which Rating Is Best?

IP65 vs IP68 Enclosures: Which Is Best?

What Is NEMA 6P? Ultimate Protection Guide

Electrical Enclosure Failures: What Reviews Miss

How to Prevent Rust in Electrical Enclosures

Electrical Enclosures for Coastal & Marine Use

Table of Contents

Like this post? Share it on:

Leo Lu

I’m Leo, the head of sales team at E-abel. Me and my team would be happy to meet you and learn all about your business, requirements and expectations.

Carson He
Carson
Paul Cao
Paul
Linsey scaled e1733988449416
Linsey
logo red

Get More Benefits Since Submit The Info Form

*We respect your confidentiality and all information are protected.

logo red

Get More Benefits Since Submit The Info Form

Leo Lu

I’m Leo, the head of sales team at E-abel. Me and my team would be happy to meet you and learn all about your business, requirements and expectations.

Carson He
Carson
Paul Cao
Paul
Linsey scaled e1733988449416
Linsey

*We respect your confidentiality and all information are protected.

Latest Articles for You

DMCA.com Protection Status
en_USEN

Contact us

logo red

Get More Benefits Since Submit The Info Form

*We respect your confidentiality and all information are protected.

Contact Us Right Now, Get Reply Today.

Leo Lu

I’m Leo, the head of sales team at E-abel. Me and my team would be happy to meet you and learn all about your business, requirements and expectations.

Carson He
Carson
Paul Cao
Paul
[contact-form-7 id="3210" title="popup form"]

Get in Touch with E-Abel

Send us an email, give us a call, or use our contact form below. We look forward to being of assistance.

[contact-form-7 id="5" title="normal form"]

Customize Your Enclosures Project

Submit your enclosure specifications below, and one of our engineers will contact you in 12 hours.

[contact-form-7 id="1606" title="Enclosures Form"]