{"id":71174,"date":"2026-10-29T07:51:25","date_gmt":"2026-10-29T07:51:25","guid":{"rendered":"https:\/\/www.eabel.com\/?p=71174"},"modified":"2026-11-03T02:41:28","modified_gmt":"2026-11-03T02:41:28","slug":"sccr-armoire-commande-industrielle","status":"publish","type":"post","link":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/","title":{"rendered":"Comment d\u00e9terminer le courant assign\u00e9 de court-circuit (SCCR) d\u2019un tableau de commande industriel"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"71174\" class=\"elementor elementor-71174\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a50b80 e-flex e-con-boxed e-con e-parent\" data-id=\"8a50b80\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba82a7 elementor-widget elementor-widget-text-editor\" data-id=\"6ba82a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">Pour d\u00e9terminer le courant assign\u00e9 de court-circuit (SCCR) d\u2019une armoire de commande industrielle, \u00e9valuez les composants de ses circuits de puissance, les dispositifs de protection ainsi que les associations ou les m\u00e9thodes de limitation du courant dans le circuit d\u2019alimentation dont l\u2019emploi est autoris\u00e9. La limite applicable la plus basse \u00e0 l\u2019issue de cette \u00e9valuation d\u00e9termine le SCCR de l\u2019armoire. Le suppl\u00e9ment SB d\u2019UL 508A fournit une m\u00e9thode analytique reconnue ; des essais de court-circuit sur l\u2019ensemble constituent une autre possibilit\u00e9.<\/p>\n<p class=\"p1\">Ce guide porte sur les armoires de commande industrielles courantes en courant alternatif basse tension destin\u00e9es aux projets am\u00e9ricains. Un concepteur d\u2019armoires ou un \u00e9valuateur qualifi\u00e9 doit appliquer les exigences correspondant \u00e0 l\u2019ensemble et \u00e0 l\u2019installation r\u00e9els.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eee58d2 e-flex e-con-boxed e-con e-parent\" data-id=\"eee58d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7e6e4db elementor-widget elementor-widget-text-editor\" data-id=\"7e6e4db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Points essentiels<\/h2>\n<ul><li>Un pouvoir de coupure \u00e9lev\u00e9 du disjoncteur principal ne suffit pas \u00e0 \u00e9tablir le SCCR de l\u2019armoire.<\/li><li>Les caract\u00e9ristiques assign\u00e9es s\u2019appliquent \u00e0 des tensions sp\u00e9cifi\u00e9es et peuvent d\u00e9pendre des dispositifs de protection exacts et des conditions d\u2019installation.<\/li><li>Le SCCR de l\u2019armoire et le courant de d\u00e9faut disponible sur le site n\u00e9cessitent des justifications distinctes.<\/li><li>Les changements de configuration et les nouvelles dispositions d\u2019alimentation n\u00e9cessitent de r\u00e9examiner les hypoth\u00e8ses concern\u00e9es relatives aux caract\u00e9ristiques assign\u00e9es ou \u00e0 l\u2019installation.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d3aed5f e-flex e-con-boxed e-con e-parent\" data-id=\"d3aed5f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-12217ec elementor-widget elementor-widget-text-editor\" data-id=\"12217ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Ce que signifie le SCCR pour une armoire de commande industrielle<\/h2><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Terme<\/th><th>Ce qu\u2019il d\u00e9crit<\/th><th>O\u00f9 le trouver<\/th><\/tr><\/thead><tbody><tr><td>SCCR de l\u2019armoire<\/td><td>Capacit\u00e9 assign\u00e9e de l\u2019ensemble \u00e0 r\u00e9sister \u00e0 un court-circuit, dans les conditions sp\u00e9cifi\u00e9es et \u00e0 la tension indiqu\u00e9e.<\/td><td>Dossier d\u2019\u00e9valuation et marquage de l\u2019armoire.<\/td><\/tr><tr><td>Pouvoir de coupure assign\u00e9 (capacit\u00e9 de coupure en amp\u00e8res, ou AIC)<\/td><td>Capacit\u00e9 d\u2019un dispositif de protection \u00e0 interrompre un courant de d\u00e9faut \u00e0 sa tension assign\u00e9e.<\/td><td>Donn\u00e9es techniques du fusible ou du disjoncteur.<\/td><\/tr><tr><td>Courant de d\u00e9faut disponible<\/td><td>Courant de d\u00e9faut pr\u00e9sum\u00e9 au point d\u2019installation. Pour les comparaisons en courant alternatif, utilisez la valeur efficace (RMS) sym\u00e9trique appropri\u00e9e.<\/td><td>\u00c9tude de court-circuit du site ou autre calcul reconnu.<\/td><\/tr><tr><td>Courant assign\u00e9 de l\u2019armoire<\/td><td>Courant assign\u00e9 de l\u2019armoire en fonctionnement normal.<\/td><td>Dossier de conception et plaque signal\u00e9tique de l\u2019armoire.<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">Pour le volet SCCR de la v\u00e9rification de l\u2019installation, le SCCR de l\u2019armoire doit \u00eatre au moins \u00e9gal au courant de d\u00e9faut disponible, et les conditions requises de tension et de protection doivent \u00eatre satisfaites. Cette comparaison ne d\u00e9termine pas l\u2019\u00e9nergie incidente d\u2019un arc \u00e9lectrique et ne remplace pas les autres v\u00e9rifications de l\u2019installation.<\/p><p class=\"p1\">Un calcul du courant de d\u00e9faut du transformateur ne suffit pas \u00e0 \u00e9tablir le SCCR de l\u2019armoire : il ne tient pas compte des caract\u00e9ristiques assign\u00e9es de l\u2019ensemble complet.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-65949\" title=\"Armoires de commande \u00e9lectriques industrielles avec panneaux ouverts\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-scaled.webp\" alt=\"Armoires de commande \u00e9lectriques industrielles avec panneaux ouverts\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-scaled.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-1536x1024.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-2048x1365.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>D\u00e9terminer le SCCR de l\u2019armoire selon UL 508A<\/h2><h3>Confirmer les conditions d\u2019alimentation et les exigences du projet<\/h3><p class=\"p1\">Confirmez la tension de fonctionnement, les phases, le sch\u00e9ma de mise \u00e0 la terre, les raccordements d\u2019alimentation et le SCCR requis pour l\u2019armoire. V\u00e9rifiez les restrictions de tension entre phases comme entre phase et terre ; un disjoncteur 480Y\/277 V ne convient pas \u00e0 tous les r\u00e9seaux 480 V. Identifiez toute alimentation distincte ou de secours qui modifie ces conditions.<\/p><p class=\"p1\">Obtenez les donn\u00e9es de courant de d\u00e9faut au point de raccordement de l\u2019armoire. La valeur au transformateur du distributeur d\u2019\u00e9lectricit\u00e9 n\u2019est pas automatiquement celle aux bornes de l\u2019armoire : les conducteurs interm\u00e9diaires et les autres conditions du r\u00e9seau interviennent. Le concepteur \u00e9lectricien du projet devrait fournir ou v\u00e9rifier ces informations.<\/p><p class=\"p1 translation-block\">V\u00e9rifiez le code \u00e9lectrique adopt\u00e9 pour le projet et les <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL508A\" target=\"_blank\" rel=\"noopener noreferrer\"><b>exigences d\u2019UL 508A<\/b><\/a> applicables. L\u2019article 409 du NEC traite du marquage et de l\u2019installation des armoires de commande industrielles. La r\u00e9vision d\u2019UL 508A de juin 2025 comporte des changements relatifs au SCCR ; v\u00e9rifiez donc les anciens tableaux et exceptions avant de les utiliser.<\/p><p class=\"p1\">M\u00eame en l\u2019absence de donn\u00e9es sur le courant de d\u00e9faut du site, le SCCR de l\u2019armoire peut \u00eatre d\u00e9termin\u00e9. L\u2019ad\u00e9quation \u00e0 l\u2019installation reste \u00e0 confirmer tant que cette comparaison distincte n\u2019a pas \u00e9t\u00e9 effectu\u00e9e.<\/p><h3>Rep\u00e9rer les composants concern\u00e9s dans les circuits de puissance<\/h3><p class=\"p1\">Partez des plans approuv\u00e9s et d\u2019une nomenclature (BOM). Un circuit d\u2019alimentation dessert les dispositifs de protection des circuits de d\u00e9rivation ; un circuit de d\u00e9rivation s\u2019\u00e9tend de son dernier dispositif de protection vers la charge. Ces limites sont importantes pour \u00e9valuer les protections.<\/p><p class=\"p1 translation-block\">Rep\u00e9rez les <a href=\"https:\/\/www.eabel.com\/fr\/composants-du-panneau-de-commande-electrique\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>composants de l\u2019armoire de commande<\/b><\/a> concern\u00e9s, notamment les sectionneurs, porte-fusibles, blocs de r\u00e9partition, jeux de barres, dispositifs de protection des circuits de d\u00e9rivation, contacteurs, relais de surcharge, variateurs, parafoudres et bornes des circuits de puissance. Incluez les voies alternatives et les circuits de contournement pr\u00e9vus dans la conception fournie.<\/p><p class=\"p1\">Classez les circuits selon leur fonction, et non selon leur seule tension. Une armoire ne comportant que des circuits de commande peut \u00eatre dispens\u00e9e du marquage SCCR ; une \u00e9tiquette 24 V ne suffit pas \u00e0 \u00e9tablir cette dispense. V\u00e9rifiez les protections contre les surintensit\u00e9s applicables \u00e0 l\u2019alimentation des circuits de commande, y compris aux primaires des transformateurs de commande et des alimentations.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-62688\" title=\"Armoires industrielles \u00e0 double paroi avec panneaux de commande\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels.webp\" alt=\"Armoires industrielles \u00e0 double paroi avec panneaux de commande\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>\u00c9tablir les caract\u00e9ristiques assign\u00e9es des composants seuls et des associations<\/h3><p class=\"p1\">Pour chaque composant concern\u00e9, relevez la r\u00e9f\u00e9rence catalogue, la tension applicable, les caract\u00e9ristiques assign\u00e9es, la protection requise et la source documentaire. Incluez les pouvoirs de coupure des fusibles et des disjoncteurs. Utilisez les marquages des produits, les instructions des fabricants et les dossiers de certification applicables.<\/p><p class=\"p1\">Lorsque leur emploi est autoris\u00e9, les valeurs par d\u00e9faut du tableau SB4.1 s\u2019appliquent \u00e0 des cat\u00e9gories de composants sp\u00e9cifi\u00e9es. Elles ne constituent pas une solution de repli universelle pour des \u00e9quipements non identifi\u00e9s. Des informations manquantes ne justifient pas l\u2019attribution d\u2019un SCCR de 5 kA par d\u00e9faut \u00e0 l\u2019armoire compl\u00e8te.<\/p><p class=\"p1 translation-block\">Les caract\u00e9ristiques assign\u00e9es d\u2019un composant seul et celles d\u2019une association soumise \u00e0 des essais constituent des justifications diff\u00e9rentes. Une association peut permettre une valeur assign\u00e9e applicable plus \u00e9lev\u00e9e si les appareils requis sont exactement ceux sp\u00e9cifi\u00e9s et si toutes les conditions requises sont respect\u00e9es. Consultez les <a href=\"https:\/\/www.ul.com\/resources\/short-circuit-current-ratings-combination-motor-controller-components\" target=\"_blank\" rel=\"noopener noreferrer\"><b>dossiers UL relatifs aux associations de commande de moteur<\/b><\/a> et la documentation du fabricant concern\u00e9.<\/p><p class=\"p1 translation-block\">V\u00e9rifiez le dispositif de protection sp\u00e9cifi\u00e9, son courant assign\u00e9 maximal, la classe du fusible ou la r\u00e9f\u00e9rence du disjoncteur, la tension ainsi que les conditions de c\u00e2blage ou d\u2019installation \u00e9ventuelles. Certaines associations imposent un volume minimal d\u2019enveloppe ou des espacements entre composants. Lors de l\u2019examen des <a href=\"https:\/\/www.eabel.com\/fr\/enclos\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>enveloppes \u00e9lectriques E-Abel<\/b><\/a>, confirmez que les dimensions int\u00e9rieures et l\u2019implantation de montage du mod\u00e8le choisi respectent les conditions sp\u00e9cifi\u00e9es pour l\u2019association.<\/p><p class=\"p1\">La valeur assign\u00e9e d\u2019une association couvre uniquement les composants identifi\u00e9s. \u00c9valuez s\u00e9par\u00e9ment les bornes ou blocs de r\u00e9partition suppl\u00e9mentaires. Un composant de remplacement de m\u00eame courant assign\u00e9 n\u00e9cessite sa propre justification documentaire pour \u00eatre accept\u00e9.<\/p><h3>\u00c9valuer la limitation du courant autoris\u00e9e dans le circuit d\u2019alimentation<\/h3><p class=\"p1\">La section SB4.3 du suppl\u00e9ment traite des m\u00e9thodes applicables de limitation du courant dans le circuit d\u2019alimentation. Selon la configuration, elles peuvent faire intervenir un transformateur de puissance \u00e0 secondaire isol\u00e9, des fusibles sp\u00e9cifi\u00e9s ou un disjoncteur homologu\u00e9 identifi\u00e9 comme limiteur de courant. Appliquez la proc\u00e9dure pertinente et ses conditions ; ne supposez pas que tous les dispositifs de protection y sont admissibles.<\/p><p class=\"p1\">Un pouvoir de coupure \u00e9lev\u00e9 ne prouve pas la limitation du courant. Examinez les donn\u00e9es de performance requises et rep\u00e9rez les composants qui b\u00e9n\u00e9ficient de la protection autoris\u00e9e. Les composants situ\u00e9s en amont de l\u2019\u00e9l\u00e9ment limiteur doivent toujours faire l\u2019objet de leur propre \u00e9valuation applicable.<\/p><p class=\"p1\">Lorsque la m\u00e9thode utilise le courant de cr\u00eate laiss\u00e9 passer, appliquez la comparaison qu\u2019elle prescrit. Une valeur cr\u00eate n\u2019est pas une valeur efficace RMS recalcul\u00e9e du courant de d\u00e9faut disponible, et la limitation du courant dans le circuit d\u2019alimentation n\u2019augmente pas automatiquement le pouvoir de coupure d\u2019un disjoncteur en aval.<\/p><p class=\"p1\">Ne confondez pas une association de commande de moteur soumise \u00e0 des essais avec le pouvoir de coupure d\u2019une association en s\u00e9rie de disjoncteurs. Un tel pouvoir de coupure concerne des dispositifs de protection sp\u00e9cifi\u00e9s qui fonctionnent ensemble ; il n\u2019attribue pas de caract\u00e9ristiques assign\u00e9es \u00e0 tous les autres composants des circuits de puissance. Un tableau de pouvoirs de coupure d\u2019associations en s\u00e9rie destin\u00e9 aux tableaux de distribution ne constitue pas une preuve g\u00e9n\u00e9rale pour une armoire de commande industrielle.<\/p><p class=\"p1\">La limite de courant de fonctionnement d\u2019un variateur de fr\u00e9quence ne constitue pas une \u00e9valuation de limitation du courant de d\u00e9faut. Pour les variateurs et autres \u00e9quipements dont la protection contre les courts-circuits est sp\u00e9cifi\u00e9e, respectez la configuration de protection publi\u00e9e et v\u00e9rifiez les restrictions applicables du suppl\u00e9ment SB avant d\u2019appliquer un ajustement du SCCR li\u00e9 au circuit d\u2019alimentation.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-62427\" title=\"Panneaux de commande \u00e9lectriques industriels avec interrupteurs et appareils de mesure\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters.webp\" alt=\"Panneaux de commande \u00e9lectriques industriels avec interrupteurs et appareils de mesure\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters-500x281.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters-18x10.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Attribuer le SCCR global et v\u00e9rifier l\u2019installation<\/h3><p class=\"p1\">\u00c9tablissez la limite applicable \u00e0 chaque circuit de d\u00e9rivation apr\u00e8s avoir \u00e9valu\u00e9 les associations valides et les ajustements autoris\u00e9s. Conservez toutes les limites impos\u00e9es par les dispositifs de protection des circuits de d\u00e9rivation. Tenez ensuite compte des composants et des dispositifs de protection du circuit d\u2019alimentation pour d\u00e9terminer le SCCR global de l\u2019armoire.<\/p><p class=\"p1\">La valeur d\u00e9terminante est la limite applicable la plus basse apr\u00e8s application des m\u00e9thodes d\u2019\u00e9valuation autoris\u00e9es. Ce n\u2019est pas n\u00e9cessairement la plus petite valeur inscrite sur un composant seul, et les caract\u00e9ristiques assign\u00e9es des composants ne s\u2019additionnent pas.<\/p><p class=\"p1\">Comparez le r\u00e9sultat au courant de d\u00e9faut disponible au point de raccordement de l\u2019armoire. Le SCCR doit \u00eatre applicable \u00e0 la tension de fonctionnement et avec les protections install\u00e9es. V\u00e9rifiez chaque raccordement d\u2019alimentation et chaque configuration pertinente, y compris les dispositifs de secours.<\/p><p class=\"p1\">Si le SCCR est trop faible, identifiez le circuit ou le composant qui le limite avant de commander des pi\u00e8ces de remplacement. Envisagez un composant ou une association dont la valeur assign\u00e9e sup\u00e9rieure est justifi\u00e9e, un dispositif de protection autoris\u00e9 ou des essais appropri\u00e9s sur l\u2019ensemble. R\u00e9\u00e9valuez la configuration concern\u00e9e avant de lui attribuer un nouveau SCCR.<\/p><h3>Exemple d\u2019application : identifier la valeur assign\u00e9e d\u00e9terminante<\/h3><p class=\"p1\">Prenons une armoire hypoth\u00e9tique aliment\u00e9e en 480 V CA sur un site o\u00f9 le courant de d\u00e9faut disponible est de 35 kA. Son dispositif de protection principal poss\u00e8de un pouvoir de coupure de 100 kA. Le circuit de d\u00e9rivation A a une valeur assign\u00e9e \u00e9tablie de 65 kA, et toutes les autres limites pertinentes sont d\u2019au moins 65 kA, \u00e0 l\u2019exception des \u00e9l\u00e9ments indiqu\u00e9s ci-dessous.<\/p><p class=\"p1\">Aucune majoration au titre de la limitation du courant dans le circuit d\u2019alimentation n\u2019est suppos\u00e9e. Toutes les valeurs assign\u00e9es sont suppos\u00e9es valables \u00e0 la tension indiqu\u00e9e, avec les conditions requises de protection et d\u2019installation satisfaites.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Configuration \u00e9valu\u00e9e<\/th><th>Valeur assign\u00e9e du circuit de d\u00e9rivation B<\/th><th>Composant de r\u00e9partition du circuit d\u2019alimentation<\/th><th>R\u00e9sultat global pour l\u2019armoire<\/th><\/tr><\/thead><tbody><tr><td>Armoire d\u2019origine<\/td><td>5 kA<\/td><td>10 kA<\/td><td>5 kA : inf\u00e9rieur aux 35 kA requis sur le site.<\/td><\/tr><tr><td>Am\u00e9lioration du circuit de d\u00e9rivation B v\u00e9rifi\u00e9e<\/td><td>65 kA<\/td><td>10 kA<\/td><td>10 kA : toujours inf\u00e9rieur \u00e0 l\u2019exigence du site.<\/td><\/tr><tr><td>Am\u00e9lioration du circuit d\u2019alimentation \u00e9galement v\u00e9rifi\u00e9e<\/td><td>65 kA<\/td><td>65 kA<\/td><td>65 kA : satisfait l\u2019exigence de courant de d\u00e9faut de cet exemple.<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">Chaque am\u00e9lioration v\u00e9rifi\u00e9e n\u00e9cessite des justificatifs des caract\u00e9ristiques assign\u00e9es des appareils r\u00e9els et des conditions d\u2019installation ; un courant assign\u00e9 de fonctionnement normal plus \u00e9lev\u00e9 ne suffit pas. La derni\u00e8re ligne d\u00e9montre la compatibilit\u00e9 du SCCR pour cet exemple, sans \u00e9tablir de certification UL ni la conformit\u00e9 \u00e0 toutes les exigences d\u2019installation.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-55441\" title=\"Armoire de commande industrielle pour automate programmable avec ventilation et composants\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-scaled.webp\" alt=\"Armoire de commande industrielle pour automate programmable avec ventilation et composants\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-scaled.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-1536x1152.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-2048x1536.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Documenter et maintenir la validit\u00e9 du SCCR v\u00e9rifi\u00e9<\/h2><p class=\"p1\">Un SCCR justifiable doit pouvoir \u00eatre reli\u00e9 \u00e0 l\u2019armoire r\u00e9ellement fournie. Conservez un dossier unique dont les r\u00e9visions sont ma\u00eetris\u00e9es, comprenant :<\/p><ul><li>La feuille d\u2019\u00e9valuation, qui relie chaque circuit concern\u00e9 aux justificatifs de ses caract\u00e9ristiques assign\u00e9es.<\/li><li>Les indices de r\u00e9vision approuv\u00e9s des plans et de la nomenclature BOM qui identifient la configuration fournie.<\/li><li>Le marquage SCCR de l\u2019armoire, y compris la tension maximale applicable et les informations sur les protections requises sur site.<\/li><li>Le courant de d\u00e9faut disponible \u00e0 l\u2019armoire, sa date de calcul, la r\u00e9f\u00e9rence du calcul ou de l\u2019\u00e9tude justificative et la configuration d\u2019alimentation \u00e9valu\u00e9e.<\/li><\/ul><p class=\"p1 translation-block\">Lorsque le SCCR d\u00e9pend d\u2019une protection fournie sur site, identifiez le dispositif requis et pr\u00e9cisez qui le fournit, l\u2019installe et le v\u00e9rifie. Les <a href=\"https:\/\/www.ul.com\/resources\/determining-short-circuit-current-rating-sccr-machinery\" target=\"_blank\" rel=\"noopener noreferrer\"><b>recommandations d\u2019UL sur le SCCR<\/b><\/a> confirment que des fusibles limiteurs de courant peuvent \u00eatre install\u00e9s dans une enveloppe distincte alimentant l\u2019armoire. Reportez ces exigences dans les documents d\u2019achat et d\u2019installation, puis v\u00e9rifiez la configuration install\u00e9e.<\/p><p class=\"p1 translation-block\">Distinguez les modifications du produit des changements du site. Le remplacement d\u2019un composant concern\u00e9, une modification du c\u00e2blage ou de l\u2019<a href=\"https:\/\/www.eabel.com\/fr\/guide-des-boitiers-de-panneaux-de-controle-industriels\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>implantation dans l\u2019enveloppe<\/b><\/a>, ou le non-respect d\u2019une condition d\u2019installation requise n\u00e9cessitent de r\u00e9examiner les justificatifs des caract\u00e9ristiques assign\u00e9es. Un changement de transformateur, d\u2019alimentation ou de lieu d\u2019installation n\u00e9cessite une nouvelle v\u00e9rification du courant de d\u00e9faut disponible et de la compatibilit\u00e9. Le SCCR \u00e9tabli de l\u2019armoire ne change pas automatiquement avec les conditions du site.<\/p><p class=\"p1 translation-block\">Pour une armoire existante d\u00e9pourvue de dossier justifiant ses caract\u00e9ristiques assign\u00e9es, demandez au fabricant ou \u00e0 un \u00e9valuateur qualifi\u00e9 d\u2019examiner sa configuration telle que construite avant de lui attribuer un SCCR. Un <a href=\"https:\/\/www.eabel.com\/fr\/liste-controle-fat-armoire-commande\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>essai de r\u00e9ception en usine<\/b><\/a> de routine ou un essai d\u2019isolement ne d\u00e9montre pas la tenue au court-circuit. De m\u00eame, une enveloppe certifi\u00e9e UL ne suffit pas \u00e0 \u00e9tablir la certification de l\u2019armoire compl\u00e8te.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-60612\" title=\"Vue d\u2019un tableau de commande industriel UL Listed d\u2019E Abel ouvert\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view.webp\" alt=\"Vue d\u2019un tableau de commande industriel UL Listed d\u2019E Abel ouvert\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Questions fr\u00e9quentes sur le SCCR des armoires de commande<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14a7ee2 elementor-widget elementor-widget-n-accordion\" data-id=\"14a7ee2\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens avec Entr\u00e9e ou Espace, fermez avec \u00c9chap et naviguez avec les touches fl\u00e9ch\u00e9es\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2160\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2160\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dois-je commander une armoire de commande d\u2019un SCCR de 65 kA ou de 100 kA ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2160\" class=\"elementor-element elementor-element-f1ef89d e-con-full e-flex e-con e-child\" data-id=\"f1ef89d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-609334b elementor-widget elementor-widget-text-editor\" data-id=\"609334b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Choisissez un SCCR au moins \u00e9gal au courant de d\u00e9faut disponible document\u00e9 sur le site, \u00e0 la tension de fonctionnement. Aucune de ces deux valeurs n\u2019est une exigence universelle. Tenez compte des am\u00e9liorations pr\u00e9vues du transformateur ou de la distribution lors de la d\u00e9finition de la sp\u00e9cification d\u2019achat.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2161\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2161\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Les valeurs Icu ou Ics selon les normes IEC peuvent-elles remplacer le SCCR d\u2019une armoire selon UL 508A ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2161\" class=\"elementor-element elementor-element-e2d87f7 e-con-full e-flex e-con e-child\" data-id=\"e2d87f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-64e7f43 elementor-widget elementor-widget-text-editor\" data-id=\"64e7f43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Non. Icu et Ics d\u00e9crivent les performances d\u2019un disjoncteur selon les exigences IEC. Elles n\u2019\u00e9tablissent pas le SCCR de l\u2019armoire compl\u00e8te, qui n\u00e9cessite une \u00e9valuation selon une m\u00e9thode reconnue de d\u00e9termination des caract\u00e9ristiques assign\u00e9es d\u2019un ensemble.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2162\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2162\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Chaque armoire de commande identique doit-elle subir des essais SCCR destructifs ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2162\" class=\"elementor-element elementor-element-fcc38e9 e-con-full e-flex e-con e-child\" data-id=\"fcc38e9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-133a35d elementor-widget elementor-widget-text-editor\" data-id=\"133a35d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Non. Le suppl\u00e9ment SB d\u2019UL 508A propose une m\u00e9thode analytique. Chaque armoire fournie doit correspondre aux composants, aux protections et \u00e0 la construction qui justifient son SCCR. Les essais de production et les exigences de certification applicables restent obligatoires.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2163\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2163\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le SCCR d\u2019une armoire de commande couvre-t-il toute la machine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2163\" class=\"elementor-element elementor-element-0e5c893 e-con-full e-flex e-con e-child\" data-id=\"0e5c893\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-33c5c0d elementor-widget elementor-widget-text-editor\" data-id=\"33c5c0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pas automatiquement. Les circuits de puissance ext\u00e9rieurs \u00e0 l\u2019armoire \u00e9valu\u00e9e peuvent influer sur les caract\u00e9ristiques assign\u00e9es globales de la machine. Demandez confirmation du SCCR de la machine compl\u00e8te et de la valeur assign\u00e9e applicable \u00e0 chaque raccordement d\u2019alimentation distinct.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2164\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2164\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une armoire de commande import\u00e9e peut-elle \u00eatre \u00e9valu\u00e9e pour une installation aux \u00c9tats-Unis apr\u00e8s sa livraison ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2164\" class=\"elementor-element elementor-element-6128609 e-con-full e-flex e-con e-child\" data-id=\"6128609\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6408da4 elementor-widget elementor-widget-text-editor\" data-id=\"6408da4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Oui. Un organisme d\u2019\u00e9valuation sur site reconnu par l\u2019autorit\u00e9 locale peut examiner l\u2019armoire concern\u00e9e et identifier les modifications requises. Organisez cette \u00e9valuation avant la mise sous tension ; une \u00e9valuation propre \u00e0 un site ne couvre pas automatiquement d\u2019autres unit\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2165\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2165\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Peut-on r\u00e9utiliser une armoire de commande apr\u00e8s un court-circuit inf\u00e9rieur \u00e0 son SCCR ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2165\" class=\"elementor-element elementor-element-dac26ff e-con-full e-flex e-con e-child\" data-id=\"dac26ff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f59ddc5 elementor-widget elementor-widget-text-editor\" data-id=\"f59ddc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div><div><div><div><div><div><div><div><div><div><div><div><div><div><div><div><div><p>Ne le supposez pas. Le marquage SCCR ne suffit pas \u00e0 confirmer l\u2019\u00e9tat des \u00e9quipements apr\u00e8s un d\u00e9faut. Le personnel \u00e9lectricien qualifi\u00e9 devrait inspecter les \u00e9quipements concern\u00e9s et suivre les instructions du fabricant concernant leur r\u00e9paration ou leur remplacement avant toute remise sous tension.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb3f5d9 elementor-widget elementor-widget-text-editor\" data-id=\"cb3f5d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-53484\" title=\"Tableau de distribution industriel avec boutons de commande\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons.webp\" alt=\"Tableau de distribution industriel avec boutons de commande\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons-500x281.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons-18x10.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><p class=\"p1\">Le SCCR d\u2019une armoire de commande industrielle repose sur la conception de ses circuits, les dispositifs de protection et les conditions document\u00e9es d\u2019attribution de ses caract\u00e9ristiques assign\u00e9es. Avant d\u2019accepter l\u2019armoire, confirmez que son SCCR s\u2019applique \u00e0 la tension de fonctionnement et qu\u2019il est au moins \u00e9gal au courant de d\u00e9faut disponible au point d\u2019installation. Obtenez les justificatifs manquants avant de valider la comparaison SCCR.<\/p><p class=\"p1 translation-block\">Pour une nouvelle armoire ou une modification de conception, utilisez ces conditions pour d\u00e9finir la sp\u00e9cification de l\u2019enveloppe. Communiquez l\u2019implantation des composants, le SCCR vis\u00e9, la tension, les protections requises et les volumes ou espacements sp\u00e9cifi\u00e9s. Incluez les besoins d\u2019entr\u00e9es de c\u00e2bles et d\u2019acc\u00e8s pour la maintenance. <a href=\"https:\/\/www.eabel.com\/fr\/contact\/\" target=\"_blank\" rel=\"noopener\"><strong>Contactez-nous<\/strong><\/a> pour discuter d\u2019une implantation dans l\u2019enveloppe qui accueille les \u00e9quipements retenus et respecte leurs exigences d\u2019installation document\u00e9es.<\/p><h2 class=\"translation-block\"><b>\u00c0 lire \u00e9galement<\/b><\/h2><p><a href=\"https:\/\/www.eabel.com\/fr\/comparaison-ul-508a-ul-67-ul-891\/\" target=\"_blank\" rel=\"noopener noreferrer\">UL 508A, UL 67 et UL 891 : principales diff\u00e9rences<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/circuit-alimentation-circuit-derive-dimensionnement-protection-nec\/\" target=\"_blank\" rel=\"noopener noreferrer\">Circuit d\u2019alimentation et circuit de d\u00e9rivation : dimensionnement et protection selon le NEC<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/qui-autorise-mise-sous-tension-tableau-electrique\/\" target=\"_blank\" rel=\"noopener noreferrer\">Qui autorise la mise sous tension d\u2019un tableau \u00e9lectrique ?<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/panneaux-de-controle-industriels-ouverts-ou-fermes\/\" target=\"_blank\" rel=\"noopener noreferrer\">Armoires de commande ouvertes ou sous enveloppe : quel choix ?<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/quelle-est-la-difference-entre-les-panneaux-de-commande-electriques-et-les-boitiers-electriques\/\" target=\"_blank\" rel=\"noopener noreferrer\">Armoire de commande ou enveloppe : que faut-il acheter ?<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>D\u00e9terminez le SCCR d\u2019une armoire de commande industrielle selon UL 508A, v\u00e9rifiez les caract\u00e9ristiques assign\u00e9es des composants et comparez-le au courant de d\u00e9faut disponible.<\/p>","protected":false},"author":17,"featured_media":71220,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[80],"tags":[],"class_list":["post-71174","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Jie Lian\"\/>\n\t<meta name=\"google-site-verification\" content=\"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"E-Abel -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How to Determine Industrial Control Panel SCCR - E-Abel\" \/>\n\t\t<meta property=\"og:description\" content=\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-29T07:51:25+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-03T02:41:28+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How to Determine Industrial Control Panel SCCR - E-Abel\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#blogposting\",\"name\":\"How to Determine Industrial Control Panel SCCR - E-Abel\",\"headline\":\"How to Determine Industrial Control Panel SCCR\",\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/jay\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\",\"width\":1448,\"height\":1086,\"caption\":\"Industrial control panel illustrating SCCR determination under UL 508A\"},\"datePublished\":\"2026-10-29T07:51:25+00:00\",\"dateModified\":\"2026-11-03T02:41:28+00:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"E-able\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#listItem\",\"name\":\"How to Determine Industrial Control Panel SCCR\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#listItem\",\"name\":\"E-able\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#listItem\",\"position\":3,\"name\":\"How to Determine Industrial Control Panel SCCR\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#organization\",\"name\":\"E-Abel\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/\",\"telephone\":\"+8618860978683\",\"foundingDate\":\"2008-08-28\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"value\":150},\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/043b221a8891a285b2aaa66333022ef.png\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#organizationLogo\",\"width\":2560,\"height\":1301,\"caption\":\"E-Abel logo form\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/jay\\\/#author\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/jay\\\/\",\"name\":\"Jie Lian\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Jie Lian\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#webpage\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/\",\"name\":\"How to Determine Industrial Control Panel SCCR - E-Abel\",\"description\":\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/jay\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/jay\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#mainImage\",\"width\":1448,\"height\":1086,\"caption\":\"Industrial control panel illustrating SCCR determination under UL 508A\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/industrial-control-panel-sccr\\\/#mainImage\"},\"datePublished\":\"2026-10-29T07:51:25+00:00\",\"dateModified\":\"2026-11-03T02:41:28+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/\",\"name\":\"E-Abel\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>How to Determine Industrial Control Panel SCCR - E-Abel<\/title>\n\n","aioseo_head_json":{"title":"Comment d\u00e9terminer le SCCR d\u2019une armoire de commande industrielle - E-Abel","description":"D\u00e9terminez le SCCR d\u2019une armoire de commande industrielle selon UL 508A, v\u00e9rifiez les caract\u00e9ristiques assign\u00e9es des composants et comparez-le au courant de d\u00e9faut disponible.","canonical_url":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"google-site-verification":"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#blogposting","name":"How to Determine Industrial Control Panel SCCR - E-Abel","headline":"How to Determine Industrial Control Panel SCCR","author":{"@id":"https:\/\/www.eabel.com\/fr\/author\/jay\/#author"},"publisher":{"@id":"https:\/\/www.eabel.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","width":1448,"height":1086,"caption":"Industrial control panel illustrating SCCR determination under UL 508A"},"datePublished":"2026-10-29T07:51:25+00:00","dateModified":"2026-11-03T02:41:28+00:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#webpage"},"isPartOf":{"@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/#listItem","position":1,"name":"E-able","item":"https:\/\/www.eabel.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/www.eabel.com\/fr\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#listItem","name":"How to Determine Industrial Control Panel SCCR"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/#listItem","name":"E-able"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#listItem","position":3,"name":"How to Determine Industrial Control Panel SCCR","previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/www.eabel.com\/fr\/#organization","name":"E-Abel","url":"https:\/\/www.eabel.com\/fr\/","telephone":"+8618860978683","foundingDate":"2008-08-28","numberOfEmployees":{"@type":"QuantitativeValue","value":150},"logo":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2022\/05\/043b221a8891a285b2aaa66333022ef.png","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#organizationLogo","width":2560,"height":1301,"caption":"E-Abel logo form"},"image":{"@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.eabel.com\/fr\/author\/jay\/#author","url":"https:\/\/www.eabel.com\/fr\/author\/jay\/","name":"Jie Lian","image":{"@type":"ImageObject","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g","width":96,"height":96,"caption":"Jie Lian"}},{"@type":"WebPage","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#webpage","url":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/","name":"How to Determine Industrial Control Panel SCCR - E-Abel","description":"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.eabel.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#breadcrumblist"},"author":{"@id":"https:\/\/www.eabel.com\/fr\/author\/jay\/#author"},"creator":{"@id":"https:\/\/www.eabel.com\/fr\/author\/jay\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#mainImage","width":1448,"height":1086,"caption":"Industrial control panel illustrating SCCR determination under UL 508A"},"primaryImageOfPage":{"@id":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/#mainImage"},"datePublished":"2026-10-29T07:51:25+00:00","dateModified":"2026-11-03T02:41:28+00:00"},{"@type":"WebSite","@id":"https:\/\/www.eabel.com\/fr\/#website","url":"https:\/\/www.eabel.com\/fr\/","name":"E-Abel","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.eabel.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"E-Abel -","og:type":"article","og:title":"How to Determine Industrial Control Panel SCCR - E-Abel","og:description":"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.","og:url":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/","og:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","og:image:secure_url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","og:image:width":1448,"og:image:height":1086,"article:published_time":"2026-10-29T07:51:25+00:00","article:modified_time":"2026-11-03T02:41:28+00:00","twitter:card":"summary_large_image","twitter:title":"How to Determine Industrial Control Panel SCCR - E-Abel","twitter:description":"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.","twitter:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp"},"aioseo_meta_data":{"post_id":"71174","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":true,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-11-03 02:43:11","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-10-29 05:22:22","updated":"2026-11-03 02:51:21","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/fr\/\" title=\"E-able\">E-able<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/fr\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tHow to Determine Industrial Control Panel SCCR\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"E-able","link":"https:\/\/www.eabel.com\/fr\/"},{"label":"Blog","link":"https:\/\/www.eabel.com\/fr\/category\/blog\/"},{"label":"How to Determine Industrial Control Panel SCCR","link":"https:\/\/www.eabel.com\/fr\/industrial-control-panel-sccr\/"}],"_links":{"self":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/posts\/71174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/comments?post=71174"}],"version-history":[{"count":0,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/posts\/71174\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/media\/71220"}],"wp:attachment":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/media?parent=71174"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/categories?post=71174"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/tags?post=71174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}