{"id":39324,"date":"2026-09-29T07:12:46","date_gmt":"2026-09-29T07:12:46","guid":{"rendered":"http:\/\/www.eabel.com\/?p=39324"},"modified":"2026-09-29T07:45:24","modified_gmt":"2026-09-29T07:45:24","slug":"comment-fonctionne-un-disjoncteur","status":"publish","type":"post","link":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/","title":{"rendered":"Comment fonctionne un disjoncteur ? Les diff\u00e9rents types expliqu\u00e9s"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"39324\" class=\"elementor elementor-39324\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c34e9d0 e-flex e-con-boxed e-con e-parent\" data-id=\"c34e9d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3ec5939 elementor-widget elementor-widget-text-editor\" data-id=\"3ec5939\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">Un disjoncteur fonctionne en ouvrant automatiquement un circuit lorsqu\u2019une surcharge ou un court-circuit actionne son m\u00e9canisme de d\u00e9clenchement. Dans un disjoncteur magn\u00e9tothermique courant, la chaleur ou la force magn\u00e9tique lib\u00e8re un m\u00e9canisme qui s\u00e9pare les contacts. Le disjoncteur \u00e9teint ensuite l\u2019arc qui se forme entre eux pour interrompre le courant.<\/p><p class=\"p1\">Ce guide explique ce processus, les risques contre lesquels prot\u00e8gent les principaux types de disjoncteurs et la mani\u00e8re d\u2019interpr\u00e9ter leurs caract\u00e9ristiques nominales. Il porte sur les disjoncteurs basse tension utilis\u00e9s dans les logements et les b\u00e2timents, en prenant principalement pour r\u00e9f\u00e9rence les applications aux \u00c9tats-Unis.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-19aa643 e-flex e-con-boxed e-con e-parent\" data-id=\"19aa643\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4e4b028 elementor-widget elementor-widget-text-editor\" data-id=\"4e4b028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Points essentiels<\/h2>\n<ul>\n<li>Les disjoncteurs magn\u00e9tothermiques r\u00e9agissent aux surcharges prolong\u00e9es comme aux courants de d\u00e9faut \u00e9lev\u00e9s, avec des temps de r\u00e9ponse diff\u00e9rents.<\/li>\n<li>Les disjoncteurs GFCI et AFCI apportent des protections que les disjoncteurs classiques contre les surintensit\u00e9s n\u2019offrent pas.<\/li>\n<li>La fonction de protection, le nombre de p\u00f4les et la cat\u00e9gorie d\u2019appareil d\u00e9crivent des caract\u00e9ristiques diff\u00e9rentes d\u2019un disjoncteur.<\/li>\n<li>Faire correspondre le courant nominal ne suffit pas : la tension, les caract\u00e9ristiques li\u00e9es aux courants de d\u00e9faut et la compatibilit\u00e9 avec le tableau comptent aussi.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ab83e2 e-flex e-con-boxed e-con e-parent\" data-id=\"9ab83e2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a277dbe elementor-widget elementor-widget-text-editor\" data-id=\"a277dbe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Comment fonctionne un disjoncteur\u202f?<\/h2><h3>Fonctionnement normal : le courant traverse les contacts ferm\u00e9s<\/h3><p class=\"p1\">Lorsque le disjoncteur est en position ON, ses contacts fixe et mobile se touchent et \u00e9tablissent un passage entre l\u2019alimentation et la charge. Un bo\u00eetier isolant maintient les pi\u00e8ces internes. La manette commande les contacts manuellement, tandis que le m\u00e9canisme de d\u00e9clenchement peut les ouvrir automatiquement.<\/p><p class=\"p1 translation-block\">Dans un <a href=\"https:\/\/www.eabel.com\/fr\/quelle-est-la-structure-interne-de-la-boite-de-distribution\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>coffret de distribution<\/b><\/a>, les disjoncteurs des circuits terminaux prot\u00e8gent chaque circuit de d\u00e9part. Un disjoncteur principal prot\u00e8ge contre les surintensit\u00e9s le tableau qu\u2019il alimente. Ces r\u00f4les d\u00e9crivent la place du disjoncteur dans l\u2019installation, et non un principe de d\u00e9clenchement diff\u00e9rent.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-65314\" title=\"Main man\u0153uvrant en s\u00e9curit\u00e9 le disjoncteur d\u2019un tableau de r\u00e9partition r\u00e9sidentiel\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Hand-operating-a-residential-panelboard-circuit-breaker-safely.webp\" alt=\"Main man\u0153uvrant en s\u00e9curit\u00e9 le disjoncteur d\u2019un tableau de r\u00e9partition r\u00e9sidentiel\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Hand-operating-a-residential-panelboard-circuit-breaker-safely.webp 1024w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Hand-operating-a-residential-panelboard-circuit-breaker-safely-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Hand-operating-a-residential-panelboard-circuit-breaker-safely-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Les surcharges activent le d\u00e9clencheur thermique<\/h3><p class=\"p1\">Une surcharge se produit lorsqu\u2019un courant trop \u00e9lev\u00e9 circule dans le trajet normal du circuit. Le fonctionnement simultan\u00e9 de plusieurs appareils puissants sur un m\u00eame circuit terminal en est un exemple courant. Si cette surintensit\u00e9 persiste, elle peut faire surchauffer les conducteurs.<\/p><p class=\"p1\">Dans un disjoncteur magn\u00e9tothermique, la chaleur produite par le courant \u00e9chauffe un bilame : deux m\u00e9taux assembl\u00e9s qui se dilatent diff\u00e9remment. Cet \u00e9l\u00e9ment se courbe en chauffant. Une surcharge prolong\u00e9e le d\u00e9forme suffisamment pour lib\u00e9rer le m\u00e9canisme de d\u00e9clenchement.<\/p><p class=\"p1\">Une surcharge plus importante provoque g\u00e9n\u00e9ralement un d\u00e9clenchement thermique plus rapide. Cette temporisation laisse passer les br\u00e8ves pointes de courant, comme celles du d\u00e9marrage d\u2019un moteur, lorsqu\u2019elles restent dans les limites de fonctionnement du disjoncteur. La temp\u00e9rature ambiante influe \u00e9galement sur la r\u00e9ponse ; le bilame ne mesure pas la temp\u00e9rature de chaque conducteur en aval.<\/p><h3>Les courants de d\u00e9faut \u00e9lev\u00e9s activent le d\u00e9clencheur magn\u00e9tique<\/h3><p class=\"p1\">Un court-circuit cr\u00e9e un trajet involontaire de faible r\u00e9sistance, qui peut laisser circuler un courant important. Par exemple, un isolant endommag\u00e9 peut permettre \u00e0 un conducteur de phase de toucher un conducteur neutre.<\/p><p class=\"p1\">Un courant plus \u00e9lev\u00e9 renforce le champ magn\u00e9tique du disjoncteur. Lorsque le seuil de d\u00e9clenchement magn\u00e9tique est atteint, la force produite lib\u00e8re le m\u00e9canisme de d\u00e9clenchement sans attendre l\u2019\u00e9chauffement du bilame.<\/p><p class=\"p1 translation-block\">Dans la <a href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA90910\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>protection magn\u00e9tothermique<\/b><\/a>, \u00ab instantan\u00e9 \u00bb signifie sans temporisation intentionnelle. Le d\u00e9placement des contacts et l\u2019extinction de l\u2019arc prennent tout de m\u00eame du temps : il n\u2019existe donc pas de temps de d\u00e9clenchement unique applicable \u00e0 tous les disjoncteurs et \u00e0 tous les d\u00e9fauts.<\/p><h3>Les contacts s\u2019ouvrent et l\u2019arc s\u2019\u00e9teint<\/h3><p class=\"p1\">Une fois le m\u00e9canisme lib\u00e9r\u00e9, l\u2019\u00e9nergie d\u2019un ressort s\u00e9pare rapidement les contacts. Une conception \u00e0 d\u00e9clenchement libre permet l\u2019ouverture automatique m\u00eame si la manette est maintenue en position ON. Ne tentez jamais de neutraliser ou de tester cette fonction en bloquant la manette.<\/p><p class=\"p1 translation-block\">Le courant peut bri\u00e8vement franchir l\u2019espace entre les contacts qui s\u2019ouvrent sous la forme d\u2019un arc, une d\u00e9charge \u00e9lectrique \u00e0 travers un gaz chaud et conducteur. Dans de nombreux disjoncteurs basse tension, une <a href=\"https:\/\/www.eaton.com\/us\/en-us\/products\/electrical-circuit-protection\/circuit-breakers\/circuit-breakers-fundamentals.html\" target=\"_blank\" rel=\"noopener noreferrer\"><b>chambre de coupure<\/b><\/a> utilise des plaques m\u00e9talliques pour diviser, refroidir et \u00e9teindre cet arc. L\u2019ouverture des contacts et l\u2019extinction de l\u2019arc assurent ensemble l\u2019interruption du courant.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-70552\" title=\"Gros plan sur un disjoncteur de tableau de r\u00e9partition\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2026\/08\/Load-center-circuit-breaker-close-up.webp\" alt=\"Gros plan sur un disjoncteur de tableau de r\u00e9partition\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/08\/Load-center-circuit-breaker-close-up.webp 1500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/08\/Load-center-circuit-breaker-close-up-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/08\/Load-center-circuit-breaker-close-up-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Types de disjoncteurs et fonctions<\/h2><p class=\"p1\">Les appellations des disjoncteurs d\u00e9crivent diff\u00e9rentes caract\u00e9ristiques. Par exemple, \u00ab disjoncteur GFCI bipolaire \u00bb indique \u00e0 la fois le nombre de p\u00f4les et la fonction de protection. Ces indications se lisent ensemble pour comprendre l\u2019appareil.<\/p><h3>Fonctions de protection : classique, GFCI, AFCI et double fonction<\/h3><p class=\"p1\">Tous les types de disjoncteurs ci-dessous int\u00e8grent une protection contre les surcharges et les courts-circuits. Ces appellations permettent de distinguer leurs r\u00f4les de protection ; les prises de courant portant des appellations similaires sont des produits distincts.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Type de disjoncteur<\/th><th>Fonction de protection<\/th><th>\u00c0 savoir<\/th><\/tr><\/thead><tbody><tr><td>Disjoncteur classique contre les surintensit\u00e9s<\/td><td>Prot\u00e8ge les conducteurs contre les surcharges et les courants de court-circuit.<\/td><td>N\u2019offre ni la protection GFCI contre les chocs \u00e9lectriques ni une d\u00e9tection sp\u00e9cifique des d\u00e9fauts d\u2019arc.<\/td><\/tr><tr><td>Disjoncteur \u00e0 protection contre les d\u00e9fauts \u00e0 la terre (GFCI)<\/td><td>D\u00e9tecte un d\u00e9s\u00e9quilibre entre le courant aller et le courant retour, contribuant \u00e0 prot\u00e9ger les personnes contre les chocs \u00e9lectriques lorsqu\u2019un courant fuit vers la terre.<\/td><td>Ne pr\u00e9vient pas toutes les formes de choc \u00e9lectrique et ne remplace pas la protection AFCI.<\/td><\/tr><tr><td>Disjoncteur \u00e0 d\u00e9tection de d\u00e9fauts d\u2019arc (AFCI)<\/td><td>D\u00e9tecte les signatures \u00e9lectriques associ\u00e9es aux arcs dangereux afin de r\u00e9duire le risque d\u2019incendie.<\/td><td>N\u2019offre pas la protection GFCI contre les chocs \u00e9lectriques, sauf si cette fonction figure \u00e9galement sur son marquage.<\/td><\/tr><tr><td>Disjoncteur \u00e0 double fonction AFCI\/GFCI<\/td><td>Associe la d\u00e9tection des d\u00e9fauts d\u2019arc \u00e0 la protection GFCI contre les d\u00e9fauts \u00e0 la terre.<\/td><td class=\"translation-block\">Un <a href=\"https:\/\/leviton.com\/support\/resources\/product-support\/protection-devices-and-receptacles\/dual-function-afci-gfci\/is-the-dual-function-afci-gfci-the-same-as-a-combination-afc\" target=\"_blank\" rel=\"noopener noreferrer\"><b>AFCI de type combin\u00e9<\/b><\/a> couvre les d\u00e9fauts d\u2019arc en s\u00e9rie et en parall\u00e8le ; cette seule appellation ne signifie pas qu\u2019il associe les fonctions AFCI et GFCI.<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">Les applications courantes comprennent la protection GFCI des prises de salle de bains et d\u2019ext\u00e9rieur, ainsi que la protection AFCI des circuits des chambres et des pi\u00e8ces de vie. Certains circuits n\u00e9cessitent les deux ; respectez le code \u00e9lectrique adopt\u00e9 localement.<\/p><p class=\"p1\">Ces fonctions suppl\u00e9mentaires peuvent provoquer un d\u00e9clenchement en dessous du courant nominal du disjoncteur. La protection classique contre les surintensit\u00e9s ne remplace pas la protection contre les surtensions, qui agit sur les pointes de tension.<\/p><h3>Nombre de p\u00f4les : unipolaire, bipolaire et tripolaire<\/h3><p class=\"p1\">Le nombre de p\u00f4les indique combien de trajets conducteurs distincts le disjoncteur ouvre. Dans un logement am\u00e9ricain typique aliment\u00e9 en 120\/240V, un disjoncteur unipolaire dessert un circuit terminal de 120V. Un disjoncteur bipolaire peut desservir un circuit de 240V ou de 120\/240V. Les disjoncteurs tripolaires desservent g\u00e9n\u00e9ralement des charges triphas\u00e9es.<\/p><p class=\"p1\">Un m\u00e9canisme de d\u00e9clenchement commun ouvre tous les p\u00f4les lorsque l\u2019un d\u2019eux d\u00e9clenche. Une simple liaison m\u00e9canique externe entre les manettes ne garantit pas un d\u00e9clenchement commun ; v\u00e9rifiez le marquage du produit.<\/p><h3>Cat\u00e9gories d\u2019appareils : disjoncteurs miniatures (MCB), \u00e0 bo\u00eetier moul\u00e9 (MCCB) et de puissance<\/h3><p class=\"p1 translation-block\">Les disjoncteurs miniatures (MCB) sont des appareils compacts pr\u00e9sents dans les <a href=\"https:\/\/www.eabel.com\/fr\/article-produit-2\/centre-de-charge-2\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>tableaux de r\u00e9partition<\/b><\/a>, les tableaux \u00e9lectriques et les ensembles mont\u00e9s sur rail DIN. Pour les applications aux \u00c9tats-Unis, v\u00e9rifiez leur aptitude \u00e0 prot\u00e9ger les circuits terminaux : un dispositif de protection suppl\u00e9mentaire UL 1077 ne peut pas remplacer un disjoncteur de circuit terminal UL 489 lorsque celui-ci est requis.<\/p><p class=\"p1\">Les disjoncteurs \u00e0 bo\u00eetier moul\u00e9 (MCCB) \u00e9quipent une grande diversit\u00e9 de circuits dans les b\u00e2timents commerciaux et les installations industrielles. Certains utilisent des d\u00e9clencheurs \u00e9lectroniques : des capteurs mesurent le courant et l\u2019\u00e9lectronique commande l\u2019ouverture selon les r\u00e9glages de protection. Un d\u00e9clencheur \u00e9lectronique ne remplace pas, \u00e0 lui seul, les contacts m\u00e9caniques du disjoncteur.<\/p><p class=\"p1\">Les disjoncteurs de puissance basse tension \u00e9quipent les grands r\u00e9seaux de distribution o\u00f9 l\u2019acc\u00e8s pour la maintenance et la coordination entre dispositifs de protection jouent un r\u00f4le important. Les cat\u00e9gories de produits se recoupent selon les march\u00e9s ; la certification et les caract\u00e9ristiques nominales d\u00e9terminent l\u2019application autoris\u00e9e.<\/p><p class=\"p1\">Dans la terminologie IEC, un interrupteur diff\u00e9rentiel (RCCB) d\u00e9tecte les d\u00e9s\u00e9quilibres de courant sans int\u00e9grer de protection contre les surintensit\u00e9s. Un disjoncteur diff\u00e9rentiel (RCBO) associe les deux fonctions. Ces seules appellations n\u2019\u00e9tablissent pas une \u00e9quivalence avec un disjoncteur GFCI homologu\u00e9 aux \u00c9tats-Unis.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-61841\" title=\"Tableau avec interrupteur en charge et disjoncteurs c\u00e2bl\u00e9s\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Panel-with-Load-Break-Switch-and-Circuit-Breakers-wired.webp\" alt=\"Tableau avec interrupteur en charge et disjoncteurs c\u00e2bl\u00e9s\" width=\"500\" height=\"342\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Panel-with-Load-Break-Switch-and-Circuit-Breakers-wired.webp 992w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Panel-with-Load-Break-Switch-and-Circuit-Breakers-wired-500x342.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Panel-with-Load-Break-Switch-and-Circuit-Breakers-wired-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Ce que r\u00e9v\u00e8lent les caract\u00e9ristiques nominales d\u2019un disjoncteur<\/h2><h3>Courant nominal, caract\u00e9ristiques de d\u00e9clenchement et pouvoir de coupure<\/h3><p class=\"p1\">Un disjoncteur portant les indications 20A et 10kA poss\u00e8de un courant nominal de 20 amp\u00e8res et un pouvoir de coupure de 10 000 amp\u00e8res. Le premier concerne le courant normal de la charge dans des conditions sp\u00e9cifi\u00e9es ; le second est le courant de d\u00e9faut maximal que le disjoncteur peut interrompre \u00e0 la tension indiqu\u00e9e, dans les conditions d\u2019essai normalis\u00e9es.<\/p><p class=\"p1\">Les caract\u00e9ristiques de d\u00e9clenchement indiquent \u00e0 quel moment le disjoncteur s\u2019ouvre pour diff\u00e9rentes intensit\u00e9s. Un courant l\u00e9g\u00e8rement sup\u00e9rieur \u00e0 20A ne provoque pas n\u00e9cessairement un d\u00e9clenchement imm\u00e9diat ; consultez la courbe temps-courant du fabricant pour ce mod\u00e8le.<\/p><p class=\"p1\">Pour les disjoncteurs classiques utilis\u00e9s aux \u00c9tats-Unis, les charges continues \u2014 celles qui sont cens\u00e9es absorber leur courant maximal pendant trois heures ou plus \u2014 sont g\u00e9n\u00e9ralement limit\u00e9es \u00e0 80% du courant nominal du disjoncteur. Il s\u2019agit d\u2019une r\u00e8gle de dimensionnement de la charge, et non d\u2019un seuil de d\u00e9clenchement. Une installation pr\u00e9vue pour fonctionner \u00e0 100% du courant nominal doit respecter les conditions d\u2019homologation du disjoncteur et de l\u2019\u00e9quipement.<\/p><h3>Tensions assign\u00e9es et compatibilit\u00e9 avec le tableau<\/h3><p class=\"p1\">V\u00e9rifiez que la tension assign\u00e9e convient au r\u00e9seau et \u00e0 son alimentation en courant alternatif (AC) ou continu (DC). Un marquage AC n\u2019\u00e9tablit pas une valeur assign\u00e9e en DC. Lorsque plusieurs tensions assign\u00e9es sont indiqu\u00e9es, lisez chacune avec le pouvoir de coupure correspondant.<\/p><p class=\"p1\">Le fait qu\u2019un disjoncteur s\u2019ins\u00e8re dans un tableau et pr\u00e9sente le m\u00eame courant nominal ne prouve pas sa compatibilit\u00e9. Respectez le marquage du tableau et la documentation de compatibilit\u00e9 applicable. Certains disjoncteurs de remplacement portant la classification UL Classified sont \u00e9valu\u00e9s pour des tableaux pr\u00e9cis d\u2019autres marques, dans des conditions d\u00e9finies.<\/p><p class=\"p1 translation-block\">L\u2019installation d\u2019un disjoncteur ayant un pouvoir de coupure sup\u00e9rieur n\u2019augmente pas automatiquement le <a href=\"https:\/\/www.ul.com\/thecodeauthority\/knowledge\/circuit-breaker-guide\" target=\"_blank\" rel=\"noopener noreferrer\"><b>courant de court-circuit assign\u00e9 du tableau<\/b><\/a>.<\/p><p class=\"p1\">Un professionnel de l\u2019\u00e9lectricit\u00e9 doit v\u00e9rifier que l\u2019ensemble peut supporter le courant de d\u00e9faut pr\u00e9sum\u00e9, c\u2019est-\u00e0-dire le courant que l\u2019alimentation pourrait fournir lors d\u2019un court-circuit. Certaines installations reposent sur une association en s\u00e9rie \u00e9valu\u00e9e pour un courant de court-circuit donn\u00e9, dans laquelle un appareil en amont contribue \u00e0 prot\u00e9ger un disjoncteur en aval. Une documentation propre \u00e0 cette association est n\u00e9cessaire.<\/p><p class=\"p1\">La protection des conducteurs, les charges raccord\u00e9es et les conditions d\u2019installation influent \u00e9galement sur le choix.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-54834\" title=\"Enveloppe NEMA 5 avec disjoncteurs et c\u00e2blage \u00e0 code couleur\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/NEMA-5-enclosure-with-circuit-breakers-and-color-coded-wiring.webp\" alt=\"Enveloppe NEMA 5 avec disjoncteurs et c\u00e2blage \u00e0 code couleur\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/NEMA-5-enclosure-with-circuit-breakers-and-color-coded-wiring.webp 865w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/NEMA-5-enclosure-with-circuit-breakers-and-color-coded-wiring-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/NEMA-5-enclosure-with-circuit-breakers-and-color-coded-wiring-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Que faire lorsqu\u2019un disjoncteur d\u00e9clenche ?<\/h2><h3>Identifier la cause avant de r\u00e9armer<\/h3><p class=\"p1\">Notez les appareils qui fonctionnaient, les modifications r\u00e9centes et tout indicateur de d\u00e9clenchement ou code de d\u00e9faut accessible d\u00e9crit dans les instructions du fabricant. Ne retirez pas les capots. Le d\u00e9lai de d\u00e9clenchement ne permet pas, \u00e0 lui seul, de distinguer de mani\u00e8re fiable une surcharge, un d\u00e9faut de c\u00e2blage ou un appareil d\u00e9fectueux.<\/p><p class=\"p1\">Si une surcharge identifi\u00e9e, due \u00e0 des appareils, a provoqu\u00e9 le d\u00e9clenchement, r\u00e9duisez la charge avant d\u2019envisager un r\u00e9armement. Si la cause n\u2019est pas claire, faites intervenir un \u00e9lectricien qualifi\u00e9. Ne r\u00e9armez qu\u2019apr\u00e8s avoir trait\u00e9 la cause et lorsque le circuit peut \u00eatre remis sous tension en toute s\u00e9curit\u00e9.<\/p><p class=\"p1\">Suivez les instructions de r\u00e9armement du fabricant. De nombreux disjoncteurs \u00e0 manette exigent de passer compl\u00e8tement en position OFF avant de revenir sur ON. Contrairement \u00e0 un fusible, un disjoncteur peut \u00eatre r\u00e9arm\u00e9 apr\u00e8s un d\u00e9clenchement, mais un r\u00e9armement r\u00e9ussi ne prouve pas qu\u2019il reste apte au service apr\u00e8s un d\u00e9faut grave.<\/p><h3>Arr\u00eater si le probl\u00e8me r\u00e9appara\u00eet<\/h3><p class=\"p1\">Si le disjoncteur d\u00e9clenche \u00e0 nouveau, laissez le circuit concern\u00e9 hors tension et faites effectuer un contr\u00f4le par un professionnel qualifi\u00e9. Une odeur de br\u00fbl\u00e9, des traces de br\u00fblure, des cr\u00e9pitements ou de l\u2019eau autour du tableau n\u00e9cessitent \u00e9galement l\u2019intervention d\u2019un professionnel. Restez \u00e0 l\u2019\u00e9cart des \u00e9quipements endommag\u00e9s ou mouill\u00e9s.<\/p><p class=\"p1 translation-block\">Les <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.334\" target=\"_blank\" rel=\"noopener noreferrer\"><b>r\u00e8gles de l\u2019OSHA sur les lieux de travail<\/b><\/a> interdisent les r\u00e9enclenchements manuels r\u00e9p\u00e9t\u00e9s apr\u00e8s le fonctionnement d\u2019une protection. En cas de <a href=\"https:\/\/www.eabel.com\/fr\/problemes-courants-du-panneau-electrique\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>probl\u00e8mes de tableau \u00e9lectrique<\/b><\/a> persistants, il faut en rechercher la cause avant de remplacer des composants.<\/p><p class=\"p1\">Consigne de s\u00e9curit\u00e9 : n\u2019augmentez jamais le courant nominal d\u2019un disjoncteur pour emp\u00eacher les d\u00e9clenchements. La coupure du disjoncteur principal peut laisser ses bornes d\u2019arriv\u00e9e sous tension ; elle ne permet pas de travailler en s\u00e9curit\u00e9 dans un tableau ouvert.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-48766\" title=\"Enveloppe \u00e9lectrique en SMC avec c\u00e2blage interne et disjoncteurs\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/02\/SMC-electrical-enclosure-with-internal-wiring-and-circuit-breakers.webp\" alt=\"Enveloppe \u00e9lectrique en SMC avec c\u00e2blage interne et disjoncteurs\" width=\"500\" height=\"413\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/02\/SMC-electrical-enclosure-with-internal-wiring-and-circuit-breakers.webp 596w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/02\/SMC-electrical-enclosure-with-internal-wiring-and-circuit-breakers-500x413.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/02\/SMC-electrical-enclosure-with-internal-wiring-and-circuit-breakers-15x12.webp 15w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Questions fr\u00e9quentes sur les disjoncteurs<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd9ad21 elementor-widget elementor-widget-n-accordion\" data-id=\"bd9ad21\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens avec Entr\u00e9e ou Espace, fermez avec \u00c9chap et naviguez avec les touches fl\u00e9ch\u00e9es\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1980\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-1980\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel calibre de disjoncteur faut-il pour mon circuit ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1980\" class=\"elementor-element elementor-element-977b6f7 e-con-full e-flex e-con e-child\" data-id=\"977b6f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40ad67c elementor-widget elementor-widget-text-editor\" data-id=\"40ad67c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Faites dimensionner le disjoncteur par un \u00e9lectricien qualifi\u00e9 en fonction des conducteurs, de la charge raccord\u00e9e et des conditions d\u2019installation. Un courant nominal plus \u00e9lev\u00e9 peut laisser des conducteurs de plus petite section sans protection adapt\u00e9e. Les charges continues et le d\u00e9marrage des moteurs influent \u00e9galement sur le choix.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1981\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1981\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Puis-je utiliser un disjoncteur d\u2019une autre marque dans mon tableau ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1981\" class=\"elementor-element elementor-element-de0504c e-con-full e-flex e-con e-child\" data-id=\"de0504c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-97c709b elementor-widget elementor-widget-text-editor\" data-id=\"97c709b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Uniquement si ce mod\u00e8le pr\u00e9cis de disjoncteur est approuv\u00e9 pour le tableau. V\u00e9rifiez le marquage du tableau et la documentation de compatibilit\u00e9. Certains disjoncteurs de remplacement portant la classification UL Classified sont \u00e9valu\u00e9s pour d\u2019autres marques, mais des dimensions et un courant nominal identiques ne suffisent pas \u00e0 \u00e9tablir la compatibilit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1982\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1982\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Ai-je besoin d\u2019un disjoncteur \u00e0 double fonction AFCI\/GFCI ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1982\" class=\"elementor-element elementor-element-0c53a87 e-con-full e-flex e-con e-child\" data-id=\"0c53a87\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0d8ba6e elementor-widget elementor-widget-text-editor\" data-id=\"0d8ba6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un disjoncteur \u00e0 double fonction prot\u00e8ge \u00e0 la fois contre les d\u00e9fauts d\u2019arc et contre les chocs \u00e9lectriques dus aux d\u00e9fauts \u00e0 la terre. C\u2019est une option lorsqu\u2019un circuit n\u00e9cessite ces deux protections. Un AFCI de type combin\u00e9 seul n\u2019offre pas de protection GFCI. V\u00e9rifiez les exigences du code \u00e9lectrique adopt\u00e9 localement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1983\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1983\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie l\u2019indication 10kA sur un disjoncteur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1983\" class=\"elementor-element elementor-element-7c73edf e-con-full e-flex e-con e-child\" data-id=\"7c73edf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dd43c67 elementor-widget elementor-widget-text-editor\" data-id=\"dd43c67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Il s\u2019agit du pouvoir de coupure du disjoncteur, soit 10 000 amp\u00e8res de courant de d\u00e9faut \u00e0 la tension sp\u00e9cifi\u00e9e, distinct de son courant nominal en fonctionnement normal. Le choix doit tenir compte du courant de d\u00e9faut pr\u00e9sum\u00e9 et du courant de court-circuit assign\u00e9 du tableau.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1984\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1984\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Puis-je utiliser un disjoncteur AC sur un circuit DC ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1984\" class=\"elementor-element elementor-element-80455be e-con-full e-flex e-con e-child\" data-id=\"80455be\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-455e69f elementor-widget elementor-widget-text-editor\" data-id=\"455e69f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Uniquement si le disjoncteur poss\u00e8de aussi des caract\u00e9ristiques assign\u00e9es adapt\u00e9es \u00e0 l\u2019application en courant continu pr\u00e9vue. V\u00e9rifiez sa tension assign\u00e9e et son pouvoir de coupure en DC, et suivez ses instructions d\u2019installation. Une tension assign\u00e9e en AC ne suffit pas \u00e0 \u00e9tablir son aptitude \u00e0 une utilisation en DC.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1985\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1985\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Faut-il remplacer un disjoncteur qui d\u00e9clenche sans cesse ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1985\" class=\"elementor-element elementor-element-a9adbb4 e-con-full e-flex e-con e-child\" data-id=\"a9adbb4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-80ebb86 elementor-widget elementor-widget-text-editor\" data-id=\"80ebb86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pas n\u00e9cessairement. Les d\u00e9clenchements peuvent provenir d\u2019une surcharge, d\u2019un d\u00e9faut de c\u00e2blage ou d\u2019un appareil raccord\u00e9 d\u00e9fectueux. Des d\u00e9clenchements r\u00e9p\u00e9t\u00e9s n\u00e9cessitent un diagnostic professionnel. Laissez le circuit concern\u00e9 hors tension jusqu\u2019\u00e0 ce que la cause soit identifi\u00e9e et corrig\u00e9e ; remplacer le disjoncteur peut ne pas r\u00e9soudre le probl\u00e8me.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d698f6f elementor-widget elementor-widget-text-editor\" data-id=\"d698f6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-40957\" title=\"Pourquoi les disjoncteurs d\u00e9clenchent 04\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/04\/why-circuit-breakers-trip-04.webp\" alt=\"Pourquoi les disjoncteurs d\u00e9clenchent 04\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/04\/why-circuit-breakers-trip-04.webp 626w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/04\/why-circuit-breakers-trip-04-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><p class=\"p1\">Les disjoncteurs prot\u00e8gent les conducteurs en interrompant le courant en cas de surcharge ou de court-circuit, tandis que les mod\u00e8les GFCI et AFCI couvrent des risques suppl\u00e9mentaires. Choisir une protection adapt\u00e9e implique de v\u00e9rifier les fonctions, les caract\u00e9ristiques nominales et la compatibilit\u00e9 du disjoncteur avec l\u2019ensemble de l\u2019installation. Le choix des disjoncteurs est donc une \u00e9tape importante de la conception des \u00e9quipements de distribution.<\/p><p class=\"p1 translation-block\">Pour un projet de coffret de distribution, de tableau de r\u00e9partition ou d\u2019enveloppe \u00e9lectrique, <a href=\"https:\/\/www.eabel.com\/fr\/contact\/\" target=\"_blank\" rel=\"noopener\"><strong>contactez notre \u00e9quipe<\/strong><\/a> afin de discuter de la configuration n\u00e9cessaire \u00e0 votre installation. Pr\u00e9cisez la tension d\u2019alimentation, les caract\u00e9ristiques des charges, le nombre de circuits et l\u2019environnement d\u2019installation pour que nous puissions \u00e9tudier les \u00e9quipements possibles et \u00e9tablir un devis selon vos besoins.<\/p><h2 class=\"translation-block\"><b>\u00c0 lire \u00e9galement<\/b><\/h2><p><a href=\"https:\/\/www.eabel.com\/fr\/mcb-contre-rcbo\/\" target=\"_blank\" rel=\"noopener noreferrer\">MCB ou RCBO : choisir le bon disjoncteur<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/circuit-alimentation-circuit-derive-dimensionnement-protection-nec\/\" target=\"_blank\" rel=\"noopener noreferrer\">Circuit d\u2019alimentation et circuit de d\u00e9rivation : dimensionnement et protection selon le NEC<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/cosse-principale-vs-disjoncteur-principal-2\/\" target=\"_blank\" rel=\"noopener noreferrer\">Tableau \u00e0 bornes d\u2019arriv\u00e9e ou \u00e0 disjoncteur principal : quelle diff\u00e9rence ?<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/eaton-ch-vs-br\/\" target=\"_blank\" rel=\"noopener noreferrer\">Eaton CH ou BR : comparaison des disjoncteurs et tableaux de r\u00e9partition<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/comment-determiner-la-taille-du-panneau-electrique\/\" target=\"_blank\" rel=\"noopener noreferrer\">Comment d\u00e9terminer le dimensionnement d\u2019un tableau \u00e9lectrique<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/fr\/appareillages-de-commutation-vs-disjoncteurs\/\" target=\"_blank\" rel=\"noopener noreferrer\">Appareillage de commutation et disjoncteurs : comprendre les principales diff\u00e9rences<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>D\u00e9couvrez comment les disjoncteurs interrompent le courant en cas de surcharge ou de court-circuit, ce qui distingue les types courants, et ce que signifient leurs caract\u00e9ristiques nominales et leurs d\u00e9clenchements r\u00e9p\u00e9t\u00e9s.<\/p>","protected":false},"author":15,"featured_media":70942,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[80],"tags":[],"class_list":["post-39324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Learn how circuit breakers stop overloads and short circuits, how common types differ, and what breaker ratings and repeated trips mean.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Carson He\"\/>\n\t<meta name=\"google-site-verification\" content=\"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"E-Abel -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How Does a Circuit Breaker Work? Types Explained - E-Abel\" \/>\n\t\t<meta property=\"og:description\" content=\"Learn how circuit breakers stop overloads and short circuits, how common types differ, and what breaker ratings and repeated trips mean.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-09-29T07:12:46+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-09-29T07:45:24+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How Does a Circuit Breaker Work? Types Explained - E-Abel\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Learn how circuit breakers stop overloads and short circuits, how common types differ, and what breaker ratings and repeated trips mean.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#blogposting\",\"name\":\"How Does a Circuit Breaker Work? Types Explained - E-Abel\",\"headline\":\"How Does a Circuit Breaker Work? Types Explained\",\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/carson-he\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Circuit-breaker-types-and-functions-explained.webp\",\"width\":1448,\"height\":1086,\"caption\":\"Circuit breaker types and functions explained\"},\"datePublished\":\"2026-09-29T07:12:46+00:00\",\"dateModified\":\"2026-09-29T07:45:24+00:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"E-able\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#listItem\",\"name\":\"How Does a Circuit Breaker Work? Types Explained\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#listItem\",\"name\":\"E-able\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#listItem\",\"position\":3,\"name\":\"How Does a Circuit Breaker Work? Types Explained\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#organization\",\"name\":\"E-Abel\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/\",\"telephone\":\"+8618860978683\",\"foundingDate\":\"2008-08-28\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"value\":150},\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/043b221a8891a285b2aaa66333022ef.png\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#organizationLogo\",\"width\":2560,\"height\":1301,\"caption\":\"E-Abel logo form\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/carson-he\\\/#author\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/carson-he\\\/\",\"name\":\"Carson He\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#authorImage\",\"url\":\"http:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/11\\\/cropped-Carson-He-96x96.jpeg\",\"width\":96,\"height\":96,\"caption\":\"Carson He\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#webpage\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/\",\"name\":\"How Does a Circuit Breaker Work? Types Explained - E-Abel\",\"description\":\"Learn how circuit breakers stop overloads and short circuits, how common types differ, and what breaker ratings and repeated trips mean.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/carson-he\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/author\\\/carson-he\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Circuit-breaker-types-and-functions-explained.webp\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#mainImage\",\"width\":1448,\"height\":1086,\"caption\":\"Circuit breaker types and functions explained\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/how-does-a-circuit-breaker-work\\\/#mainImage\"},\"datePublished\":\"2026-09-29T07:12:46+00:00\",\"dateModified\":\"2026-09-29T07:45:24+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/\",\"name\":\"E-Abel\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>How Does a Circuit Breaker Work? Types Explained - E-Abel<\/title>\n\n","aioseo_head_json":{"title":"Comment fonctionne un disjoncteur ? Les diff\u00e9rents types expliqu\u00e9s - E-Abel","description":"D\u00e9couvrez comment les disjoncteurs interrompent le courant en cas de surcharge ou de court-circuit, ce qui distingue les types courants, et ce que signifient leurs caract\u00e9ristiques nominales et leurs d\u00e9clenchements r\u00e9p\u00e9t\u00e9s.","canonical_url":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"google-site-verification":"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#blogposting","name":"How Does a Circuit Breaker Work? Types Explained - E-Abel","headline":"How Does a Circuit Breaker Work? Types Explained","author":{"@id":"https:\/\/www.eabel.com\/fr\/author\/carson-he\/#author"},"publisher":{"@id":"https:\/\/www.eabel.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp","width":1448,"height":1086,"caption":"Circuit breaker types and functions explained"},"datePublished":"2026-09-29T07:12:46+00:00","dateModified":"2026-09-29T07:45:24+00:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#webpage"},"isPartOf":{"@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/#listItem","position":1,"name":"E-able","item":"https:\/\/www.eabel.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/www.eabel.com\/fr\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#listItem","name":"How Does a Circuit Breaker Work? Types Explained"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/#listItem","name":"E-able"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#listItem","position":3,"name":"How Does a Circuit Breaker Work? Types Explained","previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/fr\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/www.eabel.com\/fr\/#organization","name":"E-Abel","url":"https:\/\/www.eabel.com\/fr\/","telephone":"+8618860978683","foundingDate":"2008-08-28","numberOfEmployees":{"@type":"QuantitativeValue","value":150},"logo":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2022\/05\/043b221a8891a285b2aaa66333022ef.png","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#organizationLogo","width":2560,"height":1301,"caption":"E-Abel logo form"},"image":{"@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.eabel.com\/fr\/author\/carson-he\/#author","url":"https:\/\/www.eabel.com\/fr\/author\/carson-he\/","name":"Carson He","image":{"@type":"ImageObject","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#authorImage","url":"http:\/\/www.eabel.com\/wp-content\/uploads\/2022\/11\/cropped-Carson-He-96x96.jpeg","width":96,"height":96,"caption":"Carson He"}},{"@type":"WebPage","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#webpage","url":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/","name":"How Does a Circuit Breaker Work? Types Explained - E-Abel","description":"Learn how circuit breakers stop overloads and short circuits, how common types differ, and what breaker ratings and repeated trips mean.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.eabel.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#breadcrumblist"},"author":{"@id":"https:\/\/www.eabel.com\/fr\/author\/carson-he\/#author"},"creator":{"@id":"https:\/\/www.eabel.com\/fr\/author\/carson-he\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp","@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#mainImage","width":1448,"height":1086,"caption":"Circuit breaker types and functions explained"},"primaryImageOfPage":{"@id":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/#mainImage"},"datePublished":"2026-09-29T07:12:46+00:00","dateModified":"2026-09-29T07:45:24+00:00"},{"@type":"WebSite","@id":"https:\/\/www.eabel.com\/fr\/#website","url":"https:\/\/www.eabel.com\/fr\/","name":"E-Abel","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.eabel.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"E-Abel -","og:type":"article","og:title":"How Does a Circuit Breaker Work? Types Explained - E-Abel","og:description":"Learn how circuit breakers stop overloads and short circuits, how common types differ, and what breaker ratings and repeated trips mean.","og:url":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/","og:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp","og:image:secure_url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp","og:image:width":1448,"og:image:height":1086,"article:published_time":"2026-09-29T07:12:46+00:00","article:modified_time":"2026-09-29T07:45:24+00:00","twitter:card":"summary_large_image","twitter:title":"How Does a Circuit Breaker Work? Types Explained - E-Abel","twitter:description":"Learn how circuit breakers stop overloads and short circuits, how common types differ, and what breaker ratings and repeated trips mean.","twitter:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/09\/Circuit-breaker-types-and-functions-explained.webp"},"aioseo_meta_data":{"post_id":"39324","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-09-29 07:46:08","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2024-06-07 07:56:31","updated":"2026-10-09 01:34:08","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/fr\/\" title=\"E-able\">E-able<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/fr\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tHow Does a Circuit Breaker Work? Types Explained\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"E-able","link":"https:\/\/www.eabel.com\/fr\/"},{"label":"Blog","link":"https:\/\/www.eabel.com\/fr\/category\/blog\/"},{"label":"How Does a Circuit Breaker Work? Types Explained","link":"https:\/\/www.eabel.com\/fr\/how-does-a-circuit-breaker-work\/"}],"_links":{"self":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/posts\/39324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/comments?post=39324"}],"version-history":[{"count":0,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/posts\/39324\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/media\/70942"}],"wp:attachment":[{"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/media?parent=39324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/categories?post=39324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eabel.com\/fr\/wp-json\/wp\/v2\/tags?post=39324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}