{"id":71772,"date":"2026-11-25T06:47:06","date_gmt":"2026-11-25T06:47:06","guid":{"rendered":"https:\/\/www.eabel.com\/?p=71772"},"modified":"2026-11-25T06:47:09","modified_gmt":"2026-11-25T06:47:09","slug":"distribucion-centro-de-datos","status":"publish","type":"post","link":"https:\/\/www.eabel.com\/es\/data-center-layout\/","title":{"rendered":"Distribuci\u00f3n de un centro de datos: gu\u00eda y buenas pr\u00e1cticas"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"71772\" class=\"elementor elementor-71772\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4e4befe e-flex e-con-boxed e-con e-parent\" data-id=\"4e4befe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e11925 elementor-widget elementor-widget-text-editor\" data-id=\"3e11925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">La distribuci\u00f3n de un centro de datos es la disposici\u00f3n f\u00edsica de los racks de TI, los equipos de alimentaci\u00f3n el\u00e9ctrica y refrigeraci\u00f3n, los recorridos del cableado y las zonas de mantenimiento. Deber\u00eda mostrar d\u00f3nde caben los equipos y c\u00f3mo se alimentar\u00e1n, refrigerar\u00e1n, mantendr\u00e1n y sustituir\u00e1n.<\/p><p class=\"p1\">Empiece por los requisitos de los equipos y, a partir de ellos, defina zonas, filas y recorridos. Esta gu\u00eda sigue ese proceso mediante un ejemplo desarrollado de 20 racks y comprobaciones previas a la puesta en servicio. Abarca salas nuevas e instalaciones existentes, donde los equipos fijos y los periodos disponibles para realizar cortes a\u00f1aden restricciones.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3029474 e-flex e-con-boxed e-con e-parent\" data-id=\"3029474\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e76837e elementor-widget elementor-widget-text-editor\" data-id=\"e76837e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Puntos clave<\/h2>\n<ul><li>Planifique a partir de la carga, las dimensiones y las necesidades de refrigeraci\u00f3n de cada rack.<\/li><li>Reserve recorridos para la entrega, el mantenimiento y la sustituci\u00f3n de equipos.<\/li><li>Coordine las instalaciones tanto en las secciones verticales como en el plano de planta.<\/li><li>Distinga entre el espacio reservado en planta y las posiciones que cuentan con capacidad de infraestructura utilizable.<\/li><li>Revise el funcionamiento normal, el mantenimiento programado y las condiciones de fallo que se deben contemplar antes de la puesta en servicio.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a58e27 e-flex e-con-boxed e-con e-parent\" data-id=\"3a58e27\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c2960ed elementor-widget elementor-widget-text-editor\" data-id=\"c2960ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Defina las cargas de los racks y las restricciones del emplazamiento<\/h2><p class=\"p1\">Elabore una relaci\u00f3n de racks antes de dibujar las filas. Asigne un identificador a cada armario y registre sus necesidades de espacio e infraestructura. Incluya los racks de red, almacenamiento y computaci\u00f3n, teniendo en cuenta las diferencias de dimensiones, volumen de cableado y acceso.<\/p><p class=\"p1\">Recopile los siguientes datos:<\/p><ul><li class=\"translation-block\">Equipos: n\u00famero de racks, <a href=\"https:\/\/www.eabel.com\/es\/gabinetes-rack-de-servidor-tamanos-profundidad-ancho-alto-explicacion\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>dimensiones exteriores de los armarios<\/b><\/a>, peso instalado, configuraci\u00f3n de env\u00edo y requisitos de acceso.<\/li><li>Demanda el\u00e9ctrica: potencia de dise\u00f1o de cada rack, tensi\u00f3n de alimentaci\u00f3n, conexiones y respuesta requerida ante el fallo de una alimentaci\u00f3n.<\/li><li class=\"translation-block\">Refrigeraci\u00f3n: sentido del flujo de aire de los equipos, <a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/A23\/IP\/A23_Ch20\/a23_ch20_ip.aspx\" target=\"_blank\" rel=\"noopener noreferrer\"><b>condiciones de funcionamiento requeridas<\/b><\/a> e interfaces de refrigeraci\u00f3n l\u00edquida, si las hay.<\/li><li>Limitaciones del emplazamiento: dimensiones medidas de la sala, pilares, altura del techo, puertas, l\u00edmites estructurales e instalaciones existentes.<\/li><li>Puesta en servicio: ocupaci\u00f3n inicial, fases posteriores, equipos que deben permanecer operativos y periodos disponibles para realizar cambios.<\/li><\/ul><p class=\"p1\">Utilice una base coherente para las cargas el\u00e9ctricas. Un valor de funcionamiento medido, un valor nominal de la placa de caracter\u00edsticas y un margen de dise\u00f1o describen cosas distintas. Identifique qu\u00e9 valor utiliza y por qu\u00e9. La suma de las cargas de dise\u00f1o de los racks establece la carga de TI prevista, mientras que la potencia total de entrada de la instalaci\u00f3n incluye tambi\u00e9n los sistemas auxiliares y las p\u00e9rdidas.<\/p><p class=\"p1\">Registre por separado las cargas iniciales y posteriores e indique los supuestos a\u00fan no confirmados. Actualice la relaci\u00f3n a medida que se seleccionen los equipos: un cambio en la combinaci\u00f3n de equipos puede modificar la infraestructura necesaria en una misma posici\u00f3n de rack.<\/p><p class=\"p1\">En una sala existente, compruebe que el plano se corresponde con la instalaci\u00f3n. Una bandeja de cables no documentada, una puerta modificada o una nueva unidad de refrigeraci\u00f3n pueden invalidar un plano que parec\u00eda correcto. Se\u00f1ale los equipos que no pueden moverse y las zonas que no pueden quedar fuera de servicio.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-60283\" title=\"Disposici\u00f3n sim\u00e9trica de aparamenta de MT para un centro de datos\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use.webp\" alt=\"Disposici\u00f3n sim\u00e9trica de aparamenta de MT para un centro de datos\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use.webp 1880w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use-1536x1022.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/Symmetrical-MV-switchgear-setup-for-data-center-use-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Defina las zonas, los accesos y la ampliaci\u00f3n de la sala<\/h2><h3>Asigne zonas para TI e infraestructura auxiliar<\/h3><p class=\"p1\">Delimite la zona de racks, la infraestructura el\u00e9ctrica y de refrigeraci\u00f3n, las zonas de entrada de red o de interconexi\u00f3n y el espacio de recepci\u00f3n o preparaci\u00f3n de equipos. En una sala peque\u00f1a se pueden utilizar zonas funcionales; las instalaciones m\u00e1s grandes pueden necesitar salas separadas y controles de acceso.<\/p><p class=\"p1\">Sit\u00fae los equipos de distribuci\u00f3n e interconexi\u00f3n de modo que tengan recorridos viables hasta los racks a los que dan servicio. Mantenga los embalajes y las zonas de preparaci\u00f3n temporal fuera de las v\u00edas de acceso operativo.<\/p><p class=\"p1\">Incluya en el plano inicial los controles de las puertas, las salidas de emergencia y la coordinaci\u00f3n de la protecci\u00f3n contra incendios. Las puertas y los techos de los sistemas de contenci\u00f3n deben ajustarse al dise\u00f1o aprobado de detecci\u00f3n y extinci\u00f3n de incendios y de evacuaci\u00f3n.<\/p><h3>Proteja los recorridos de mantenimiento y sustituci\u00f3n<\/h3><p class=\"p1\">Trace los recorridos de entrega y sustituci\u00f3n de los equipos cuyas dimensiones, peso o necesidades de manipulaci\u00f3n sean determinantes. Compruebe las puertas, los giros, los ascensores, las rampas y los l\u00edmites de carga del recorrido. Encargue al equipo de estructuras la evaluaci\u00f3n de las cargas concentradas en los apoyos y de las cargas rodantes cuando sea necesario; la carga media sobre el suelo no basta para determinar su idoneidad.<\/p><p class=\"p1 translation-block\">Distinga entre las zonas de circulaci\u00f3n habitual, el espacio de mantenimiento de los equipos y el espacio de trabajo el\u00e9ctrico que corresponda. En Estados Unidos, los <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.303\" target=\"_blank\" rel=\"noopener noreferrer\"><b>requisitos del espacio de trabajo el\u00e9ctrico<\/b><\/a> incluyen condiciones que van m\u00e1s all\u00e1 de poder abrir la puerta de un armario, y el espacio de trabajo exigido no puede utilizarse para almacenamiento.<\/p><h3>Reserve zonas de ampliaci\u00f3n y obras<\/h3><p class=\"p1\">Marque las futuras posiciones de racks e indique el estado de su infraestructura: espacio reservado, trabajos de infraestructura previstos o posici\u00f3n lista para la puesta en servicio. As\u00ed se evita considerar que una superficie vac\u00eda equivale a capacidad operativa disponible.<\/p><p class=\"p1\">Indique d\u00f3nde se realizar\u00e1n las obras posteriores y c\u00f3mo acceder\u00e1n los trabajadores. En una instalaci\u00f3n en servicio, defina los l\u00edmites de aislamiento, los periodos de migraci\u00f3n, el apoyo temporal necesario y un plan de reversi\u00f3n. Si una futura fila obliga a bloquear el \u00fanico recorrido de sustituci\u00f3n, habr\u00e1 que cambiar la disposici\u00f3n antes de la instalaci\u00f3n inicial.<\/p><p class=\"p1\">Vincule cada fase de ampliaci\u00f3n a las tareas de infraestructura necesarias, como prolongar recorridos, a\u00f1adir equipos de distribuci\u00f3n o proporcionar conexiones de refrigeraci\u00f3n. Asigne responsables y fechas de finalizaci\u00f3n para que la siguiente fase tenga una secuencia definida hasta su puesta en servicio.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-59334\" title=\"Racks de centro de datos con cerradura de armario controlada por teclado\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock.webp\" alt=\"Racks de centro de datos con cerradura de armario controlada por teclado\" width=\"500\" height=\"301\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock.webp 1986w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock-500x301.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock-1536x923.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Data-center-racks-with-keypad-secured-enclosure-lock-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Disponga las filas de racks y la refrigeraci\u00f3n<\/h2><h3>Adapte la geometr\u00eda de los racks a las necesidades de mantenimiento<\/h3><p class=\"p1 translation-block\">Al evaluar productos como los <a href=\"https:\/\/www.eabel.com\/es\/armarios-rack-servidor-2\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>armarios rack para servidores de E-abel<\/b><\/a>, compare las dimensiones exteriores propuestas, las posiciones de los ra\u00edles y la disposici\u00f3n de las entradas de cables con la relaci\u00f3n de equipos. Incluya los accesorios que sobresalgan hacia un pasillo; la anchura interior de montaje no determina la superficie que ocupa el armario en planta.<\/p><p class=\"p1\">Fije las dimensiones de los pasillos y de los extremos de las filas seg\u00fan las condiciones de acceso ya identificadas. Tenga en cuenta las puertas abiertas, los equipos deslizantes, los organizadores de cables, los dispositivos de alimentaci\u00f3n montados en la parte trasera y los \u00fatiles de elevaci\u00f3n necesarios. Un rack que cabe en el plano tambi\u00e9n debe permitir la tarea de mantenimiento que requiera m\u00e1s espacio. Compruebe los intercambiadores de calor de puerta trasera y las conexiones de mangueras seg\u00fan el espacio que necesiten para su propio mantenimiento, en lugar de utilizar las dimensiones de una puerta de rack est\u00e1ndar.<\/p><h3>Separe el aire de impulsi\u00f3n del aire de salida<\/h3><p class=\"p1\">Para un flujo de aire de delante hacia atr\u00e1s, disponga los racks con los frentes enfrentados a ambos lados de los pasillos fr\u00edos y las partes traseras enfrentadas a ambos lados de los pasillos calientes. Alinee las salidas de impulsi\u00f3n y los recorridos de retorno con estos pasillos y adapte el flujo de aire de lado a lado mediante conductos o soluciones adecuadas en los armarios.<\/p><p class=\"p1 translation-block\">Utilice <a href=\"https:\/\/www.energy.gov\/sites\/default\/files\/2024-07\/best-practice-guide-data-center-design_0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><b>medidas de gesti\u00f3n del aire<\/b><\/a>, como paneles ciegos y pasos de cables sellados, para limitar las mezclas y las fugas. Elija la contenci\u00f3n del pasillo fr\u00edo o caliente seg\u00fan el sistema de refrigeraci\u00f3n, la protecci\u00f3n contra incendios y el acceso para mantenimiento. Contraste las necesidades de caudal de aire de cada rack con el caudal disponible; la capacidad total de refrigeraci\u00f3n de la sala no garantiza un caudal de aire adecuado en todas las entradas.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-59077\" title=\"Grandes racks de servidores negros con ventiladores de refrigeraci\u00f3n en un centro de datos 1024x786\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1.webp\" alt=\"Grandes racks de servidores negros con ventiladores de refrigeraci\u00f3n en un centro de datos 1024x786\" width=\"500\" height=\"384\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1.webp 1024w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1-500x384.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/Large-black-server-racks-with-cooling-fans-in-a-data-center-1024x786-1-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Compare las configuraciones del suelo<\/h3><p class=\"p1\">Ambas configuraciones del suelo admiten sistemas compatibles de refrigeraci\u00f3n por aire o l\u00edquida. Compruebe las condiciones estructurales y de distribuci\u00f3n que se indican a continuaci\u00f3n.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Opci\u00f3n de distribuci\u00f3n<\/th><th>Implicaciones para la refrigeraci\u00f3n y los recorridos<\/th><th>Comprobaciones antes de decidir<\/th><\/tr><\/thead><tbody><tr><td>Suelo t\u00e9cnico elevado<\/td><td>Puede proporcionar un pl\u00e9num de aire o espacio para infraestructuras; tambi\u00e9n permite recorridos superiores<\/td><td>Losa estructural, paneles y apoyos del suelo, cargas rodantes, altura libre del pl\u00e9num, pasos y acceso para mantenimiento<\/td><\/tr><tr><td>Sin suelo t\u00e9cnico elevado<\/td><td>Utiliza otras disposiciones de impulsi\u00f3n de aire y recorridos coordinados para las instalaciones, a menudo por la parte superior<\/td><td>Cargas estructurales, altura disponible, soportes, acceso para mantenimiento e interferencias entre sistemas superiores<\/td><\/tr><\/tbody><\/table><\/div><h3>Reserve espacio para la refrigeraci\u00f3n l\u00edquida<\/h3><p class=\"p1 translation-block\">Si los equipos requieren refrigeraci\u00f3n l\u00edquida, utilice las <a href=\"https:\/\/www.opencompute.org\/documents\/ocp-acf-reference-design-guidance-white-paper-r1-pdf\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>directrices para planificar la distribuci\u00f3n de l\u00edquido<\/b><\/a> a fin de reservar espacio para los equipos de refrigeraci\u00f3n seleccionados, incluida una unidad de distribuci\u00f3n de refrigerante, o CDU, cuando sea necesaria. Tenga en cuenta las tuber\u00edas, los colectores, las v\u00e1lvulas, las conexiones de mangueras, el acceso para mantenimiento y la detecci\u00f3n y supervisi\u00f3n de fugas especificadas.<\/p><p class=\"p1\">Siga el recorrido del calor m\u00e1s all\u00e1 del rack. Una CDU l\u00edquido-aire situada en la sala de TI a\u00f1ade el calor que disipa a la carga de refrigeraci\u00f3n por aire de esa sala. Una configuraci\u00f3n l\u00edquido-l\u00edquido transfiere el calor a otro circuito de refrigeraci\u00f3n. Al planificar la integraci\u00f3n de la refrigeraci\u00f3n l\u00edquida, compruebe tanto la carga de los equipos que siguen refriger\u00e1ndose por aire como la capacidad del sistema de l\u00edquido.<\/p><p class=\"p1\">No existe un umbral universal de potencia por rack que determine el m\u00e9todo de refrigeraci\u00f3n para todos los proyectos. Utilice los requisitos de los proveedores de los equipos y de la refrigeraci\u00f3n para resolver esa elecci\u00f3n.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-54358\" title=\"Centros de datos\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers.webp\" alt=\"Centros de datos\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers.webp 1440w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Coordine la alimentaci\u00f3n el\u00e9ctrica y los recorridos del cableado<\/h2><h3>Compruebe las v\u00edas A\/B y la capacidad en caso de fallo<\/h3><p class=\"p1\">Trace el recorrido desde la distribuci\u00f3n aguas arriba hasta cada conexi\u00f3n de rack. Distinga las unidades de distribuci\u00f3n de energ\u00eda de la instalaci\u00f3n, o PDU, de las PDU de rack, que distribuyen la energ\u00eda dentro de un armario. Los cuadros remotos de distribuci\u00f3n el\u00e9ctrica ofrecen otro posible punto de distribuci\u00f3n de circuitos derivados. Utilice el esquema unifilar el\u00e9ctrico del proyecto, una representaci\u00f3n simplificada de las conexiones el\u00e9ctricas, para identificar la disposici\u00f3n real.<\/p><p class=\"p1\">Cuando cualquiera de las dos alimentaciones deba soportar toda la carga de TI, verifique la capacidad utilizable de toda la v\u00eda que permanezca en servicio, incluidos los circuitos, las conexiones y las PDU de rack. Dos v\u00edas de 150 kW no pueden proporcionar redundancia total para una carga de 300 kW, aunque ninguna est\u00e9 sobrecargada durante el reparto normal de carga.<\/p><p class=\"p1\">Identifique los equipos compartidos aguas arriba y los puntos comunes de recorrido o soporte, y confirme que los equipos de TI pueden seguir funcionando tras perder una alimentaci\u00f3n. Las etiquetas A\/B identifican las v\u00edas, pero no garantizan su independencia ni acreditan una clasificaci\u00f3n Tier.<\/p><p class=\"p1 translation-block\">Reserve espacio para utilizar y mantener los <a href=\"https:\/\/www.eabel.com\/es\/armarios-distribucion-electrica-centros-datos\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>armarios de distribuci\u00f3n el\u00e9ctrica<\/b><\/a>, las unidades de derivaci\u00f3n de canalizaciones prefabricadas y los dispositivos de transferencia que alimentan equipos con un solo cable de alimentaci\u00f3n. Un dispositivo de transferencia no hace redundante la fuente de alimentaci\u00f3n del propio equipo conectado. Compruebe el acceso a los conectores y el alcance de los cables; la construcci\u00f3n enchufable por s\u00ed sola no autoriza la instalaci\u00f3n ni la retirada en tensi\u00f3n.<\/p><p class=\"p1\">En el plano de una canalizaci\u00f3n prefabricada a\u00e9rea, muestre las unidades de derivaci\u00f3n adem\u00e1s del eje de la canalizaci\u00f3n. Sus dimensiones, mandos de accionamiento, direcci\u00f3n de salida de los cables y acceso para la instalaci\u00f3n pueden afectar al espacio disponible alrededor de un rack. Confirme estos detalles con el sistema seleccionado antes de fijar las posiciones de las bandejas o de los sistemas de contenci\u00f3n pr\u00f3ximos.<\/p><h3>Coordine los recorridos de datos y las instalaciones superiores<\/h3><p class=\"p1 translation-block\">Sit\u00fae los equipos de interconexi\u00f3n y de red de modo que los recorridos reales de los cables respeten los l\u00edmites y los requisitos de instalaci\u00f3n del medio de transmisi\u00f3n elegido. La conmutaci\u00f3n en la parte superior del rack y la conmutaci\u00f3n al final de la fila generan necesidades de recorrido distintas. Compruebe los <a href=\"https:\/\/www.eabel.com\/es\/gestion-de-cables-en-racks-de-servidores\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>requisitos de organizaci\u00f3n del cableado<\/b><\/a>, incluidos la capacidad de las bandejas, el radio de curvatura, los soportes, el etiquetado y el acceso a lo largo de cada recorrido. Cuando el dise\u00f1o requiera conexiones por recorridos f\u00edsicamente independientes, trace ambas v\u00edas hasta los puntos de distribuci\u00f3n o entrada especificados e identifique cualquier bandeja, conducto o paso compartido que pueda anular esa separaci\u00f3n.<\/p><p class=\"p1\">A\u00f1ada una secci\u00f3n vertical de una fila representativa que muestre las cotas de las bandejas de cables, las canalizaciones prefabricadas, las tuber\u00edas de refrigeraci\u00f3n, los sistemas de contenci\u00f3n, los soportes, la iluminaci\u00f3n y los sistemas de protecci\u00f3n contra incendios. En las envolventes el\u00e9ctricas, muestre el espacio de entrada de cables y de apertura de paneles, el acceso para la instalaci\u00f3n y cualquier espacio dedicado a instalaciones el\u00e9ctricas que resulte aplicable. Compruebe que cada instalaci\u00f3n puede mantenerse sin bloquear el acceso a otra e incluya las conexiones de puesta a tierra necesarias.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-54567\" title=\"Centros de datos\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1.webp\" alt=\"Centros de datos\" width=\"500\" height=\"316\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1.webp 570w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1-500x316.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/07\/Data-Centers-1-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Ejemplo: distribuci\u00f3n de un centro de datos de 20 racks<\/h2><p class=\"p1\">Considere un ejemplo did\u00e1ctico con dos filas de diez racks orientados hacia un pasillo fr\u00edo compartido. Suponga que cada armario mide 0.6 m de ancho y 1.2 m de fondo, sin separaciones adicionales entre armarios contiguos. Asigne 1.2 m al pasillo central, a cada pasillo trasero exterior y a cada extremo de fila. Son supuestos de c\u00e1lculo, no espacios de mantenimiento aprobados ni m\u00ednimos normativos.<\/p><p class=\"p1\">La longitud b\u00e1sica de la fila es 10 \u00d7 0.6 + 2 \u00d7 1.2 = 8.4 m. En sentido transversal a las filas, el fondo es 2 \u00d7 1.2 + 3 \u00d7 1.2 = 6.0 m. El bloque resultante de racks y pasillos ocupa 50.4 m\u00b2, o unos 543 ft\u00b2.<\/p><p class=\"p1\">Asigne ahora distintas cargas de dise\u00f1o a los armarios:<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Grupo de racks<\/th><th>N\u00famero de racks<\/th><th>Carga de dise\u00f1o por rack<\/th><th>Carga de TI del grupo<\/th><\/tr><\/thead><tbody><tr><td>Grupo de carga est\u00e1ndar<\/td><td>16<\/td><td>8 kW<\/td><td>128 kW<\/td><\/tr><tr><td>Grupo de mayor carga<\/td><td>4<\/td><td>28 kW<\/td><td>112 kW<\/td><\/tr><tr><td>Total<\/td><td>20<\/td><td>\u2014<\/td><td>240 kW<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">La media es de 12 kW por rack, pero los cuatro armarios de 28 kW representan aproximadamente el 47% de la carga de TI. Suponga ahora que cada fila dispone de 140 kW de capacidad el\u00e9ctrica utilizable para las condiciones evaluadas. Situar los cuatro armarios de mayor carga junto con seis armarios de 8 kW da lugar a una fila de 160 kW y deja la otra en 80 kW. La capacidad conjunta es de 280 kW, pero la primera fila supera su l\u00edmite.<\/p><p class=\"p1\">Sit\u00fae en su lugar dos armarios de 28 kW y ocho de 8 kW en cada fila, y cada fila sumar\u00e1 120 kW. Esta disposici\u00f3n supera la comprobaci\u00f3n de potencia por fila supuesta en el ejemplo. A\u00fan es necesario validar los circuitos individuales y la refrigeraci\u00f3n local. Agrupar los racks de mayor carga sigue siendo una opci\u00f3n v\u00e1lida cuando disponen de infraestructura dedicada; repartirlos no es una regla universal.<\/p><p class=\"p1\">A\u00f1ada espacio independiente para los equipos el\u00e9ctricos y de refrigeraci\u00f3n, la entrada de red, la preparaci\u00f3n de equipos y la ampliaci\u00f3n. Vuelva a comprobar los pasillos supuestos con las puertas, los \u00fatiles de mantenimiento y las necesidades de sustituci\u00f3n de equipos reales. El bloque calculado es solo una parte de la sala.<\/p><p class=\"p1\">El total de 240 kW es una carga de dise\u00f1o de TI. La selecci\u00f3n de un sistema de alimentaci\u00f3n ininterrumpida, o UPS, de los circuitos derivados y de los equipos de refrigeraci\u00f3n requiere c\u00e1lculos independientes para las condiciones de funcionamiento y resiliencia del proyecto.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-45428\" title=\"T\u00e9cnicos instalando servidores en racks abiertos en un centro de datos\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/10\/Technicians-installing-servers-into-open-racks-in-a-data-center.webp\" alt=\"T\u00e9cnicos instalando servidores en racks abiertos en un centro de datos\" width=\"500\" height=\"418\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/10\/Technicians-installing-servers-into-open-racks-in-a-data-center.webp 674w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/10\/Technicians-installing-servers-into-open-racks-in-a-data-center-14x12.webp 14w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Valide la distribuci\u00f3n antes de la puesta en servicio<\/h2><h3>Compruebe el funcionamiento normal y las condiciones locales<\/h3><p class=\"p1\">Superponga los planos de arquitectura, estructuras, electricidad, instalaciones mec\u00e1nicas, red y protecci\u00f3n contra incendios. Compruebe que las posiciones de los equipos y las cotas de los recorridos coinciden en todos ellos. Revise las cargas locales de los racks con respecto a la capacidad asignada a sus conexiones y zonas de refrigeraci\u00f3n.<\/p><p class=\"p1\">Mida condiciones representativas en las entradas de aire de los equipos en lugar de basarse en una \u00fanica lectura media de la sala. Incluya los puntos y las alturas en los que el dise\u00f1o prevea variaciones relevantes. Las zonas con refrigeraci\u00f3n l\u00edquida necesitan la supervisi\u00f3n especificada para sus circuitos de refrigerante y sus riesgos de fuga.<\/p><p class=\"p1\">En los equipos refrigerados por aire, distinga el intervalo de funcionamiento recomendado de los l\u00edmites admisibles, m\u00e1s amplios. Durante el funcionamiento normal, busque mantenerse en el intervalo recomendado que corresponda; permanecer dentro de los l\u00edmites admisibles no basta para establecer un objetivo adecuado a largo plazo. Confirme la clase del equipo y las especificaciones del fabricante en lugar de aplicar el mismo intervalo de temperatura a todos los racks. Ajuste los umbrales de supervisi\u00f3n a esos requisitos.<\/p><p class=\"p1\">Utilice la din\u00e1mica de fluidos computacional, o CFD, cuando sea necesario analizar el flujo de aire. Registre las cargas de los equipos, la geometr\u00eda y las condiciones de refrigeraci\u00f3n supuestas para que el modelo pueda revisarse y compararse m\u00e1s adelante con mediciones sobre el terreno.<\/p><h3>Revise el mantenimiento y las condiciones de fallo que se deben contemplar<\/h3><p class=\"p1\">Repase paso a paso las tareas de sustituci\u00f3n que requieran m\u00e1s espacio o equipos de manipulaci\u00f3n. Incluya los \u00fatiles de elevaci\u00f3n y una zona designada para depositar los componentes retirados, manteniendo despejados el espacio de trabajo el\u00e9ctrico y las v\u00edas de evacuaci\u00f3n y conservando las condiciones de funcionamiento requeridas.<\/p><p class=\"p1\">Revise un escenario en el que los servidores sigan alimentados por UPS, pero la refrigeraci\u00f3n esencial pierda alimentaci\u00f3n el\u00e9ctrica o caudal. Determine las necesidades de alimentaci\u00f3n de respaldo y rearranque de las bombas, los ventiladores, los controles y cualquier CDU, incluidos los equipos compartidos que dan servicio a varios racks. Encargue al equipo de ingenier\u00eda que determine cu\u00e1nto tiempo pueden funcionar los equipos de TI dentro de sus l\u00edmites tras interrumpirse la refrigeraci\u00f3n. Verifique que la recuperaci\u00f3n o la parada controlada previstas se puedan completar dentro de ese tiempo de autonom\u00eda t\u00e9rmica; el respaldo el\u00e9ctrico por s\u00ed solo no garantiza la continuidad del funcionamiento.<\/p><p class=\"p1 translation-block\">Encargue a los equipos de ingenier\u00eda y puesta en marcha que verifiquen los escenarios de alimentaci\u00f3n el\u00e9ctrica y refrigeraci\u00f3n requeridos. En los proyectos que busquen una certificaci\u00f3n Tier, utilice las <a href=\"https:\/\/uptimeinstitute.com\/tiers\" target=\"_blank\" rel=\"noopener noreferrer\"><b>directrices de clasificaci\u00f3n Tier<\/b><\/a> para comprender el nivel previsto y, despu\u00e9s, verifique el dise\u00f1o con respecto a la norma Tier aplicable. Defina criterios de aceptaci\u00f3n medibles: condiciones en las entradas de aire de los equipos, carga admisible de los circuitos, acceso requerido y continuidad de servicio especificada. Las pruebas en sistemas en servicio necesitan personal cualificado que trabaje conforme a un plan aprobado con pasos de recuperaci\u00f3n.<\/p><p class=\"p1\">Registre las desviaciones y resu\u00e9lvalas conforme a los requisitos de dise\u00f1o. Conserve los resultados de aceptaci\u00f3n como referencia para los cambios posteriores.<\/p><h3>Complete la documentaci\u00f3n operativa<\/h3><p class=\"p1 translation-block\">Actualice el plano de planta para que refleje los equipos instalados y mant\u00e9ngalo coordinado con las tareas habituales de <a href=\"https:\/\/www.eabel.com\/es\/lista-de-verificacion-de-mantenimiento-de-racks-de-servidores-para-centros-de-datos\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>mantenimiento de los racks de servidores<\/b><\/a>. Vincule los identificadores de los racks con los circuitos, los recorridos del cableado, las zonas de refrigeraci\u00f3n y los puntos de supervisi\u00f3n. El software de gesti\u00f3n de la infraestructura del centro de datos puede mantener estas relaciones, pero la documentaci\u00f3n sigue necesitando un responsable y un proceso de gesti\u00f3n de cambios.<\/p><p class=\"p1\">Exija revisar la distribuci\u00f3n cuando un traslado o una incorporaci\u00f3n modifiquen la carga, el flujo de aire, los recorridos o el acceso. El plano aprobado deber\u00eda seguir siendo \u00fatil despu\u00e9s de la primera puesta en servicio.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-43686\" title=\"Filas de servidores de red y cables en un centro de datos\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/07\/Rows-of-network-servers-and-cables-in-a-data-center.webp\" alt=\"Filas de servidores de red y cables en un centro de datos\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/07\/Rows-of-network-servers-and-cables-in-a-data-center.webp 1023w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/07\/Rows-of-network-servers-and-cables-in-a-data-center-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Preguntas frecuentes sobre la distribuci\u00f3n de centros de datos<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f609b71 elementor-widget elementor-widget-n-accordion\" data-id=\"f609b71\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Acorde\u00f3n. Abra los enlaces con Intro o Espacio, ci\u00e9rrelos con Escape y navegue con las teclas de flecha\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2570\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2570\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfC\u00f3mo deber\u00eda comparar las propuestas de distribuci\u00f3n de un centro de datos? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2570\" class=\"elementor-element elementor-element-293a2c7 e-con-full e-flex e-con e-child\" data-id=\"293a2c7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-124dfda elementor-widget elementor-widget-text-editor\" data-id=\"124dfda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilice una misma relaci\u00f3n de equipos, las mismas cargas de los racks y los mismos requisitos de funcionamiento para comparar las propuestas. Pida a cada dise\u00f1ador que muestre la capacidad utilizable de los racks, el espacio para equipos auxiliares, el acceso para mantenimiento y las previsiones de ampliaci\u00f3n. Compare los costes con el mismo alcance, incluida la infraestructura necesaria para que cada posici\u00f3n de rack est\u00e9 operativa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2571\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2571\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfPuedo reutilizar los racks de servidores existentes en una nueva distribuci\u00f3n del centro de datos? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2571\" class=\"elementor-element elementor-element-ea03441 e-con-full e-flex e-con e-child\" data-id=\"ea03441\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-19659e3 elementor-widget elementor-widget-text-editor\" data-id=\"19659e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ed, si sus dimensiones, ra\u00edles de montaje, capacidades de carga y estado son adecuados para los equipos previstos. Compruebe el flujo de aire, el espacio para cables y la compatibilidad de los accesorios antes de mantenerlos en el dise\u00f1o. Reutilizar un armario solo ahorra dinero si las modificaciones y los trabajos de instalaci\u00f3n necesarios siguen siendo viables.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2572\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2572\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfDeber\u00eda elegir armarios rack para servidores de 600 mm o de 800 mm de ancho? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2572\" class=\"elementor-element elementor-element-860dd59 e-con-full e-flex e-con e-child\" data-id=\"860dd59\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6df9e9c elementor-widget elementor-widget-text-editor\" data-id=\"6df9e9c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un armario de 600 mm permite mantener una fila compacta. Uno de 800 mm puede ofrecer m\u00e1s espacio lateral para organizar el cableado y colocar PDU de rack verticales. Compruebe el espacio utilizable del modelo elegido con sus equipos instalados; la anchura exterior por s\u00ed sola no confirma el espacio libre disponible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2573\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2573\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 debe incluir un presupuesto de armarios rack para servidores? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2573\" class=\"elementor-element elementor-element-ae29b49 e-con-full e-flex e-con e-child\" data-id=\"ae29b49\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5da3c39 elementor-widget elementor-widget-text-editor\" data-id=\"5da3c39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Solicite las dimensiones exactas, la profundidad de montaje, las capacidades de carga, los planos y los accesorios incluidos. Confirme si las puertas, los paneles laterales, los organizadores de cables, los paneles ciegos y las PDU de rack est\u00e1n incluidos o se presupuestan por separado. Aclare tambi\u00e9n la configuraci\u00f3n de entrega y qui\u00e9n se encarga de la instalaci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2574\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2574\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfCu\u00e1ndo necesito armarios rack para servidores a medida? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2574\" class=\"elementor-element elementor-element-5d4d6ed e-con-full e-flex e-con e-child\" data-id=\"5d4d6ed\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7fd32f6 elementor-widget elementor-widget-text-editor\" data-id=\"7fd32f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Considere la personalizaci\u00f3n cuando los armarios est\u00e1ndar no puedan satisfacer los requisitos verificados de montaje, entrada de cables, espacio o mantenimiento. Compare un armario a medida con la posibilidad de ajustar la distribuci\u00f3n antes de decidir. Confirme la capacidad de carga de la configuraci\u00f3n final y los requisitos de conformidad aplicables en lugar de basarse en las especificaciones de un modelo est\u00e1ndar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2575\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2575\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQui\u00e9n deber\u00eda aprobar la distribuci\u00f3n de un centro de datos antes de pedir los equipos? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2575\" class=\"elementor-element elementor-element-3b8f695 e-con-full e-flex e-con e-child\" data-id=\"3b8f695\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b89148 elementor-widget elementor-widget-text-editor\" data-id=\"3b89148\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El promotor del proyecto deber\u00eda coordinar la aprobaci\u00f3n con los equipos responsables de los requisitos el\u00e9ctricos, de refrigeraci\u00f3n, estructurales y de protecci\u00f3n contra incendios. El proveedor de los armarios deber\u00eda confirmar las dimensiones de los equipos, los detalles de montaje y las entradas de cables. Mantenga separadas la aprobaci\u00f3n de los planos de los armarios y la aprobaci\u00f3n de la distribuci\u00f3n de la instalaci\u00f3n completa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f550e7 elementor-widget elementor-widget-text-editor\" data-id=\"2f550e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusi\u00f3n<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-42680\" title=\"Centro de datos moderno con racks de servidores y pantallas LED azules\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/06\/Modern-data-center-with-server-racks-and-blue-LED-displays.webp\" alt=\"Centro de datos moderno con racks de servidores y pantallas LED azules\" width=\"500\" height=\"312\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/06\/Modern-data-center-with-server-racks-and-blue-LED-displays.webp 1250w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/06\/Modern-data-center-with-server-racks-and-blue-LED-displays-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><p class=\"p1\">Una buena distribuci\u00f3n de un centro de datos proporciona a cada rack una ubicaci\u00f3n con la infraestructura necesaria: una posici\u00f3n f\u00edsica, una conexi\u00f3n el\u00e9ctrica adecuada, un recorrido de refrigeraci\u00f3n y un acceso viable. La planificaci\u00f3n es m\u00e1s s\u00f3lida cuando estos requisitos se revisan conjuntamente y se contrastan con las tareas que realizar\u00e1n los operadores. Un plano claro con los supuestos indicados facilita la evaluaci\u00f3n de las opciones de equipos y los cambios posteriores.<\/p><p class=\"p1 translation-block\">Antes de solicitar propuestas de equipos, concrete las cargas previstas de los racks, las dimensiones disponibles, las fases de instalaci\u00f3n y las condiciones de funcionamiento requeridas. Esto ofrece a los proveedores una base \u00fatil para comprobar el encaje y aclarar las interfaces. <a href=\"https:\/\/www.eabel.com\/es\/contacto\/\" target=\"_blank\" rel=\"noopener\"><strong>Contacte con E-abel<\/strong><\/a> y facilite el plano de planta, la relaci\u00f3n de racks, los par\u00e1metros de alimentaci\u00f3n y los requisitos de las envolventes para comentar las configuraciones adecuadas de racks y armarios el\u00e9ctricos. Compartir estos datos desde el principio ayuda a detectar dudas sobre la entrada de cables, el montaje y el espacio de mantenimiento antes de pedir los equipos.<\/p><h2 class=\"translation-block\"><b>Lecturas relacionadas<\/b><\/h2><p><a href=\"https:\/\/www.eabel.com\/es\/seleccionar-el-gabinete-rack-para-centro-de-datos-adecuado\/\" target=\"_blank\" rel=\"noopener noreferrer\">C\u00f3mo elegir un armario rack para su centro de datos<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/sellar-las-juntas-del-rack-de-servidores\/\" target=\"_blank\" rel=\"noopener noreferrer\">Sellado de huecos en los racks de servidores para mejorar el flujo de aire<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/seleccionar-la-pdu-adecuada-para-los-recintos-del-centro-de-datos\/\" target=\"_blank\" rel=\"noopener noreferrer\">C\u00f3mo elegir la PDU adecuada para su centro de datos<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/cuadro-distribucion-remoto-centro-datos\/\" target=\"_blank\" rel=\"noopener noreferrer\">\u00bfQu\u00e9 es un cuadro remoto de distribuci\u00f3n el\u00e9ctrica en un centro de datos?<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/racks-de-servidores-modulares-para-centros-de-datos\/\" target=\"_blank\" rel=\"noopener noreferrer\">Racks de servidores modulares para centros de datos ampliables<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/electrical-cabinets-modular-data-centers\/\" target=\"_blank\" rel=\"noopener noreferrer\">Armarios el\u00e9ctricos para centros de datos modulares<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Planifique la distribuci\u00f3n de un centro de datos con orientaci\u00f3n pr\u00e1ctica sobre la ubicaci\u00f3n de racks, la refrigeraci\u00f3n, la alimentaci\u00f3n el\u00e9ctrica, el cableado, el acceso para mantenimiento y el crecimiento futuro.<\/p>","protected":false},"author":17,"featured_media":71796,"comment_status":"open","ping_status":"open","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[80],"tags":[],"class_list":["post-71772","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.6.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"Jie Lian\"\/>\n\t<meta name=\"google-site-verification\" content=\"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.eabel.com\/es\/data-center-layout\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.6.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"E-Abel -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Data Center Layout: Guide and Best Practices - E-Abel\" \/>\n\t\t<meta property=\"og:description\" content=\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.eabel.com\/es\/data-center-layout\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-25T06:47:06+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-25T06:47:09+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Data Center Layout: Guide and Best Practices - E-Abel\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#blogposting\",\"name\":\"Data Center Layout: Guide and Best Practices - E-Abel\",\"headline\":\"Data Center Layout: Guide and Best Practices\",\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Data-center-layout-with-two-rows-of-server-racks.webp\",\"width\":1448,\"height\":1086,\"caption\":\"Data center layout with two rows of server racks\"},\"datePublished\":\"2026-11-25T06:47:06+00:00\",\"dateModified\":\"2026-11-25T06:47:09+00:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"E-able\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#listItem\",\"name\":\"Data Center Layout: Guide and Best Practices\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#listItem\",\"name\":\"E-able\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#listItem\",\"position\":3,\"name\":\"Data Center Layout: Guide and Best Practices\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#organization\",\"name\":\"E-Abel\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/\",\"telephone\":\"+8618860978683\",\"foundingDate\":\"2008-08-28\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"value\":150},\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/043b221a8891a285b2aaa66333022ef.png\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#organizationLogo\",\"width\":2560,\"height\":1301,\"caption\":\"E-Abel logo form\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/\",\"name\":\"Jie Lian\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Jie Lian\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#webpage\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/\",\"name\":\"Data Center Layout: Guide and Best Practices - E-Abel\",\"description\":\"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Data-center-layout-with-two-rows-of-server-racks.webp\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#mainImage\",\"width\":1448,\"height\":1086,\"caption\":\"Data center layout with two rows of server racks\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/data-center-layout\\\/#mainImage\"},\"datePublished\":\"2026-11-25T06:47:06+00:00\",\"dateModified\":\"2026-11-25T06:47:09+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/\",\"name\":\"E-Abel\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Data Center Layout: Guide and Best Practices - E-Abel<\/title>\n\n","aioseo_head_json":{"title":"Distribuci\u00f3n de un centro de datos: gu\u00eda y buenas pr\u00e1cticas - E-Abel","description":"Planifique la distribuci\u00f3n de un centro de datos con orientaci\u00f3n pr\u00e1ctica sobre la ubicaci\u00f3n de racks, la refrigeraci\u00f3n, la alimentaci\u00f3n el\u00e9ctrica, el cableado, el acceso para mantenimiento y el crecimiento futuro.","canonical_url":"https:\/\/www.eabel.com\/es\/data-center-layout\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"google-site-verification":"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#blogposting","name":"Data Center Layout: Guide and Best Practices - E-Abel","headline":"Data Center Layout: Guide and Best Practices","author":{"@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author"},"publisher":{"@id":"https:\/\/www.eabel.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","width":1448,"height":1086,"caption":"Data center layout with two rows of server racks"},"datePublished":"2026-11-25T06:47:06+00:00","dateModified":"2026-11-25T06:47:09+00:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#webpage"},"isPartOf":{"@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/#listItem","position":1,"name":"E-able","item":"https:\/\/www.eabel.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/www.eabel.com\/es\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#listItem","name":"Data Center Layout: Guide and Best Practices"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/#listItem","name":"E-able"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#listItem","position":3,"name":"Data Center Layout: Guide and Best Practices","previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/www.eabel.com\/es\/#organization","name":"E-Abel","url":"https:\/\/www.eabel.com\/es\/","telephone":"+8618860978683","foundingDate":"2008-08-28","numberOfEmployees":{"@type":"QuantitativeValue","value":150},"logo":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2022\/05\/043b221a8891a285b2aaa66333022ef.png","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#organizationLogo","width":2560,"height":1301,"caption":"E-Abel logo form"},"image":{"@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author","url":"https:\/\/www.eabel.com\/es\/author\/jay\/","name":"Jie Lian","image":{"@type":"ImageObject","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g","width":96,"height":96,"caption":"Jie Lian"}},{"@type":"WebPage","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#webpage","url":"https:\/\/www.eabel.com\/es\/data-center-layout\/","name":"Data Center Layout: Guide and Best Practices - E-Abel","description":"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.eabel.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#breadcrumblist"},"author":{"@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author"},"creator":{"@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#mainImage","width":1448,"height":1086,"caption":"Data center layout with two rows of server racks"},"primaryImageOfPage":{"@id":"https:\/\/www.eabel.com\/es\/data-center-layout\/#mainImage"},"datePublished":"2026-11-25T06:47:06+00:00","dateModified":"2026-11-25T06:47:09+00:00"},{"@type":"WebSite","@id":"https:\/\/www.eabel.com\/es\/#website","url":"https:\/\/www.eabel.com\/es\/","name":"E-Abel","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.eabel.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"E-Abel -","og:type":"article","og:title":"Data Center Layout: Guide and Best Practices - E-Abel","og:description":"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.","og:url":"https:\/\/www.eabel.com\/es\/data-center-layout\/","og:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","og:image:secure_url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp","og:image:width":1448,"og:image:height":1086,"article:published_time":"2026-11-25T06:47:06+00:00","article:modified_time":"2026-11-25T06:47:09+00:00","twitter:card":"summary_large_image","twitter:title":"Data Center Layout: Guide and Best Practices - E-Abel","twitter:description":"Plan a data center layout with practical guidance on rack placement, cooling, power, cabling, service access, and future growth.","twitter:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Data-center-layout-with-two-rows-of-server-racks.webp"},"aioseo_meta_data":{"post_id":"71772","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":false,"robots_noindex":true,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-11-25 06:47:28","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-11-25 02:59:34","updated":"2026-11-25 06:52:45","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/es\/\" title=\"E-able\">E-able<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/es\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tData Center Layout: Guide and Best Practices\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"E-able","link":"https:\/\/www.eabel.com\/es\/"},{"label":"Blog","link":"https:\/\/www.eabel.com\/es\/category\/blog\/"},{"label":"Data Center Layout: Guide and Best Practices","link":"https:\/\/www.eabel.com\/es\/data-center-layout\/"}],"_links":{"self":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/posts\/71772","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/comments?post=71772"}],"version-history":[{"count":0,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/posts\/71772\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/media\/71796"}],"wp:attachment":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/media?parent=71772"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/categories?post=71772"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/tags?post=71772"}],"curies":[{"name":"Gracias","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}