{"id":71130,"date":"2026-10-23T06:36:53","date_gmt":"2026-10-23T06:36:53","guid":{"rendered":"https:\/\/www.eabel.com\/?p=71130"},"modified":"2026-10-27T07:26:37","modified_gmt":"2026-10-27T07:26:37","slug":"lista-comprobacion-fat-cuadros-control","status":"publish","type":"post","link":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/","title":{"rendered":"Lista de comprobaci\u00f3n de las pruebas de aceptaci\u00f3n en f\u00e1brica de cuadros de control antes del env\u00edo"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"71130\" class=\"elementor elementor-71130\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e255286 e-flex e-con-boxed e-con e-parent\" data-id=\"e255286\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8aae4c4 elementor-widget elementor-widget-text-editor\" data-id=\"8aae4c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">La prueba de aceptaci\u00f3n en f\u00e1brica (FAT) de un cuadro de control verifica el conjunto suministrado y las funciones de control incluidas frente a los requisitos aprobados antes del env\u00edo. Deber\u00eda aportar algo m\u00e1s que una lista de comprobaci\u00f3n cumplimentada: los compradores necesitan evidencias de los resultados, de las incidencias pendientes y de la configuraci\u00f3n aceptada para la entrega.<\/p><p class=\"p1\">Esta gu\u00eda trata sobre cuadros de control industriales. Las comprobaciones mec\u00e1nicas, de cableado y el\u00e9ctricas aplicables constituyen la base. Las pruebas del PLC, la HMI, la red y los variadores se aplican cuando esos dispositivos y funciones est\u00e1n incluidos en el pedido. Utilice la lista de comprobaci\u00f3n para elaborar un procedimiento espec\u00edfico del proyecto, sin sustituir las normas aplicables ni las instrucciones de los equipos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2bc4669 e-flex e-con-boxed e-con e-parent\" data-id=\"2bc4669\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1eabb53 elementor-widget elementor-widget-text-editor\" data-id=\"1eabb53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Puntos clave<\/h2>\n<ul>\n<li>Vincule cada prueba a un requisito aprobado, un resultado esperado y evidencias registradas.<\/li>\n<li>Identifique el hardware, el software y las interfaces simuladas utilizados durante las pruebas.<\/li>\n<li>Verifique la respuesta ante fallos y la recuperaci\u00f3n junto con el funcionamiento normal.<\/li>\n<li>Apruebe el env\u00edo tomando como referencia la configuraci\u00f3n final, una vez completadas las correcciones exigidas y los registros de entrega.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-96338eb e-flex e-con-boxed e-con e-parent\" data-id=\"96338eb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6973dba elementor-widget elementor-widget-text-editor\" data-id=\"6973dba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Defina el alcance de la FAT y los criterios de aceptaci\u00f3n<\/h2><h3>Establezca la base de referencia aprobada<\/h3><p class=\"p1 translation-block\">Identifique el cuadro y los documentos que definen el pedido: planos el\u00e9ctricos aprobados, lista de materiales (BOM), relaciones de bornes y requisitos funcionales aplicables. Utilice la BOM para identificar los <a href=\"https:\/\/www.eabel.com\/es\/componentes-del-panel-de-control-electrico\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>componentes del cuadro de control el\u00e9ctrico<\/b><\/a> incluidos en la inspecci\u00f3n. En los sistemas programables, incluya la lista de I\/O y las versiones de software pertinentes.<\/p><p class=\"p1\">Confirme las responsabilidades del proveedor. Un pedido de fabricaci\u00f3n conforme a planos suministrados puede incluir el montaje y el cableado, sin la programaci\u00f3n de la m\u00e1quina ni la validaci\u00f3n del proceso. La FAT deber\u00eda evaluar el alcance adquirido e identificar claramente las interfaces suministradas por terceros.<\/p><p class=\"p1\">Resuelva las discrepancias entre revisiones antes de las pruebas. El esquema, la relaci\u00f3n de bornes y el procedimiento de prueba deben describir la misma disposici\u00f3n.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-59851\" title=\"Panel frontal de armario con PLC, HMI y pulsadores de control\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/PLC-cabinet-front-panel-with-HMI-and-control-buttons.webp\" alt=\"Panel frontal de armario con PLC, HMI y pulsadores de control\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/PLC-cabinet-front-panel-with-HMI-and-control-buttons.webp 1707w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/PLC-cabinet-front-panel-with-HMI-and-control-buttons-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/PLC-cabinet-front-panel-with-HMI-and-control-buttons-1536x1152.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/10\/PLC-cabinet-front-panel-with-HMI-and-control-buttons-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Defina criterios de aceptaci\u00f3n observables<\/h3><p class=\"p1\">Cada registro de prueba deber\u00eda identificar el requisito, el m\u00e9todo, el resultado esperado, el resultado real, las evidencias y la persona que realiza la prueba. Incluya la fecha y el testigo cuando se exija. En las mediciones, registre la identificaci\u00f3n del instrumento y el estado de calibraci\u00f3n aplicable.<\/p><p class=\"p1\">Sustituya \u00abcomprobar el funcionamiento\u00bb por comportamientos observables. La prueba de una secuencia de bombeo deber\u00eda definir las condiciones de arranque, la salida ordenada, la se\u00f1al de retorno esperada y la respuesta si esta no llega.<\/p><p class=\"p1 translation-block\">Antes de la FAT, acuerde los puntos de prueba con presencia de testigos, los registros de pruebas existentes que se aceptar\u00e1n y la autoridad responsable de autorizar el env\u00edo. Para los sistemas de automatizaci\u00f3n de la industria de procesos, la norma <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/67572\" target=\"_blank\" rel=\"noopener noreferrer\"><b>IEC 62381:2024<\/b><\/a> ofrece un marco para las pruebas de aceptaci\u00f3n espec\u00edficas de cada proyecto; no es un requisito general para todos los cuadros de control.<\/p><h3>Identifique las interfaces reales y simuladas<\/h3><p class=\"p1\">Registre qu\u00e9 dispositivos de campo, cargas y conexiones de red est\u00e1n disponibles, c\u00f3mo se simular\u00e1n los equipos que falten y qu\u00e9 comprobaciones requieren pruebas de aceptaci\u00f3n en el emplazamiento (SAT).<\/p><p class=\"p1\">El m\u00e9todo de prueba limita las conclusiones. Inyectar una se\u00f1al en un borne de campo comprueba un recorrido distinto al de forzar un valor dentro del controlador l\u00f3gico programable (PLC). Un valor correcto en la interfaz hombre-m\u00e1quina (HMI) no demuestra, por s\u00ed solo, que el cableado externo de los bornes sea correcto.<\/p><p class=\"p1\">Identifique como tales los resultados simulados. Pueden satisfacer una prueba acordada en f\u00e1brica sin demostrar el rendimiento en las condiciones reales del emplazamiento.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-55441\" title=\"Cuadro de control industrial con PLC, ventilaci\u00f3n y componentes\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-scaled.webp\" alt=\"Cuadro de control industrial con PLC, ventilaci\u00f3n y componentes\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-scaled.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-1536x1152.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-2048x1536.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Lista de comprobaci\u00f3n FAT de cuadros de control<\/h2><p class=\"p1\">El personal cualificado deber\u00eda identificar y aislar las fuentes de alimentaci\u00f3n pertinentes, aplicar las medidas exigidas de control de energ\u00edas y verificar la ausencia de tensi\u00f3n antes de las comprobaciones que requieran equipos sin tensi\u00f3n. Realice la puesta en tensi\u00f3n controlada y las pruebas funcionales \u00fanicamente conforme a los procedimientos aprobados de seguridad el\u00e9ctrica y de prueba.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>\u00c1rea de comprobaci\u00f3n<\/th><th>Qu\u00e9 verificar<\/th><th>Evidencias que deben registrarse<\/th><\/tr><\/thead><tbody><tr><td>Identificaci\u00f3n, caracter\u00edsticas nominales y componentes del cuadro<\/td><td class=\"translation-block\">La identificaci\u00f3n del cuadro, los componentes instalados y las sustituciones coinciden con los documentos aprobados. Las caracter\u00edsticas nominales del conjunto cumplen los requisitos el\u00e9ctricos y ambientales especificados. Cuando proceda, confirme que la <a href=\"https:\/\/www.ul.com\/resources\/determining-short-circuit-current-rating-sccr-machinery\" target=\"_blank\" rel=\"noopener noreferrer\"><b>corriente nominal de cortocircuito (SCCR)<\/b><\/a> del conjunto es, como m\u00ednimo, igual a la corriente de defecto disponible en el punto de instalaci\u00f3n, a la tensi\u00f3n especificada y con las condiciones exigidas para los dispositivos de protecci\u00f3n satisfechas. Los marcados de certificaci\u00f3n exigidos corresponden al conjunto suministrado.<\/td><td>Registros de la placa de caracter\u00edsticas, revisi\u00f3n de la BOM, aprobaciones de sustituciones, verificaci\u00f3n de las caracter\u00edsticas nominales aplicables y referencias de certificaci\u00f3n.<\/td><\/tr><tr><td>Construcci\u00f3n mec\u00e1nica y envolvente<\/td><td>Los dispositivos y los elementos de fijaci\u00f3n est\u00e1n bien sujetos. Las puertas, cerraduras, manetas y enclavamientos mec\u00e1nicos funcionan correctamente. Las juntas, las placas de entrada de cables, las aberturas, el espacio de acceso y el estado del armario se ajustan al dise\u00f1o aprobado. El interior est\u00e1 libre de virutas met\u00e1licas y otros residuos.<\/td><td>Resultados de la inspecci\u00f3n, dimensiones pertinentes y fotograf\u00edas de la construcci\u00f3n.<\/td><\/tr><tr><td>Cableado y terminaciones<\/td><td>Las conexiones coinciden con los esquemas y las relaciones de bornes. Compruebe la identificaci\u00f3n de los conductores y bornes, la polaridad, la selecci\u00f3n de conductores, la separaci\u00f3n, el apantallamiento y las terminaciones conforme al dise\u00f1o y a las instrucciones de los componentes.<\/td><td>Hojas de inspecci\u00f3n punto a punto, referencias de los planos y registros de apriete exigidos.<\/td><\/tr><tr><td>Conexiones equipotenciales de protecci\u00f3n y pruebas el\u00e9ctricas<\/td><td>Verifique las conexiones equipotenciales de protecci\u00f3n y realice las pruebas exigidas por los requisitos aplicables y el procedimiento aprobado. Identifique los puntos de prueba, los l\u00edmites y los dispositivos que requieren aislamiento el\u00e9ctrico o protecci\u00f3n.<\/td><td>Resultados medidos, l\u00edmites de aceptaci\u00f3n, identificaci\u00f3n de los instrumentos y registros de desconexi\u00f3n y restituci\u00f3n de conexiones.<\/td><\/tr><tr><td>Puesta en tensi\u00f3n controlada y funciones auxiliares<\/td><td>Confirme la disposici\u00f3n de la alimentaci\u00f3n, la configuraci\u00f3n de los dispositivos de protecci\u00f3n, las tensiones de control y los estados de arranque. Si est\u00e1n instalados, compruebe los ventiladores del armario, los calefactores, los controles de temperatura y las alarmas de refrigeraci\u00f3n en las condiciones de prueba especificadas. Investigue los disparos, fallos o salidas inesperados antes de continuar.<\/td><td>Lecturas de tensi\u00f3n, observaciones durante el arranque, resultados de las funciones auxiliares, registros de fallos y ajustes pertinentes.<\/td><\/tr><tr><td>Verificaci\u00f3n de I\/O<\/td><td>Compruebe el direccionamiento, el sentido de las se\u00f1ales, el escalado anal\u00f3gico y la respuesta conforme a la lista de I\/O. Identifique d\u00f3nde se introduce el est\u00edmulo y d\u00f3nde se observa la respuesta.<\/td><td>Hojas de comprobaci\u00f3n de puntos, n\u00famero de pruebas previstas y realizadas, y tratamiento de los puntos no probados o no aplicables. Registre el alcance de cualquier muestreo aprobado.<\/td><\/tr><tr><td>Secuencias del PLC y modos de funcionamiento<\/td><td>Pruebe el comportamiento manual\/autom\u00e1tico y local\/remoto especificado, las secuencias, las condiciones de habilitaci\u00f3n, los enclavamientos, los temporizadores y las prioridades de las \u00f3rdenes.<\/td><td>Resultados de las pruebas vinculados a los requisitos funcionales, con las tendencias o los registros de eventos pertinentes.<\/td><\/tr><tr><td>HMI y alarmas<\/td><td>Verifique los identificadores de las variables de la HMI, los valores, las unidades, los permisos de acceso, las condiciones de activaci\u00f3n y los mensajes de las alarmas, as\u00ed como su reconocimiento y el comportamiento de rearme.<\/td><td>Referencias de pantallas, registros de alarmas y resultados para los perfiles de operador acordados.<\/td><\/tr><tr><td>Comunicaciones<\/td><td>Confirme las direcciones, la asignaci\u00f3n de datos, el intercambio de \u00f3rdenes y estados y las interfaces exigidas utilizando los equipos disponibles. Identifique las conexiones simuladas o los dispositivos sustituidos.<\/td><td>Configuraci\u00f3n de red, resultados de las interfaces y versiones de los dispositivos probados.<\/td><\/tr><tr><td>Respuesta ante fallos y recuperaci\u00f3n<\/td><td>Pruebe las p\u00e9rdidas de alimentaci\u00f3n y de comunicaci\u00f3n, los fallos de sensores y los disparos de dispositivos que sean aplicables. Verifique los estados de las salidas, los diagn\u00f3sticos y la recuperaci\u00f3n, incluidos los permisos de rearranque, conforme a los requisitos aprobados.<\/td><td>Est\u00edmulo del fallo, respuesta observada, resultado de la recuperaci\u00f3n y desviaciones.<\/td><\/tr><tr><td>Funciones relacionadas con la seguridad<\/td><td>Compruebe las funciones suministradas conforme a los requisitos de seguridad y al plan de validaci\u00f3n aprobados. Identifique las verificaciones que requieren la m\u00e1quina o instalaci\u00f3n final.<\/td><td>Registros de validaci\u00f3n aplicables, configuraci\u00f3n probada y tareas pendientes asignadas.<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1 translation-block\">En los proyectos que utilizan las <a href=\"https:\/\/www.eabel.com\/es\/recintos\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>envolventes el\u00e9ctricas de E-abel<\/b><\/a>, los formatos murales, autoportantes y modulares ofrecen distintas opciones de montaje y acceso. Identifique el armario seleccionado y su distribuci\u00f3n f\u00edsica aprobada en los documentos de fabricaci\u00f3n; las responsabilidades relativas al suministro de la envolvente y a la aceptaci\u00f3n funcional del cuadro completo deber\u00edan quedar claramente definidas.<\/p><h3>Utilice procedimientos de pruebas el\u00e9ctricas espec\u00edficos del equipo<\/h3><p class=\"p1\">No hay valores universales para el l\u00edmite de resistencia de aislamiento, la tensi\u00f3n de ensayo diel\u00e9ctrico, el l\u00edmite aplicable a las conexiones equipotenciales o el par de apriete de bornes que sirvan para todos los cuadros de control. Las pruebas exigidas, las alternativas permitidas y los valores de aceptaci\u00f3n dependen de la norma aplicable, del conjunto y de las instrucciones de los componentes.<\/p><p class=\"p1\">Antes de las pruebas de aislamiento o diel\u00e9ctricas, identifique los dispositivos electr\u00f3nicos y los componentes de protecci\u00f3n que requieran desconexi\u00f3n u otras precauciones. Una prueba incorrecta puede da\u00f1ar los equipos. Documente las desconexiones temporales y verifique la restituci\u00f3n de las conexiones antes de poner en tensi\u00f3n los circuitos afectados o someterlos a pruebas funcionales.<\/p><p class=\"p1 translation-block\">Revise las evidencias de la SCCR y del grado de protecci\u00f3n de la envolvente a partir del dise\u00f1o aplicable, los marcados y los registros justificativos. Una FAT rutinaria no determina la capacidad frente a cortocircuitos ni certifica la envolvente mediante pruebas funcionales ordinarias. La <a href=\"https:\/\/www.ul.com\/services\/industrial-control-panels-and-panel-shop-program\" target=\"_blank\" rel=\"noopener noreferrer\"><b>certificaci\u00f3n de cuadros conforme a UL 508A<\/b><\/a> y la aceptaci\u00f3n funcional atienden a requisitos distintos; ninguna sustituye a la otra.<\/p><p class=\"p1 translation-block\">Si el pedido combina control industrial y distribuci\u00f3n de energ\u00eda, determine <a href=\"https:\/\/www.eabel.com\/es\/comparacion-ul-508a-ul-67-ul-891\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>qu\u00e9 requisitos son aplicables seg\u00fan UL 508A, UL 67 o UL 891<\/b><\/a> antes de aceptar los registros de certificaci\u00f3n.<\/p><h3>Compruebe la secuencia completa de recuperaci\u00f3n<\/h3><p class=\"p1\">Despu\u00e9s de cada fallo simulado, verifique la secuencia de recuperaci\u00f3n especificada, incluidos los requisitos de rearme y los permisos de rearranque. El restablecimiento de la alimentaci\u00f3n o de la comunicaci\u00f3n no debe provocar un arranque ni una salida no intencionados.<\/p><p class=\"p1\">Para las funciones relacionadas con la seguridad, registre lo que pudo verificarse con la configuraci\u00f3n de f\u00e1brica y asigne la validaci\u00f3n pendiente del sistema integrado a la parte responsable conforme al plan de seguridad aprobado.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-56935\" title=\"Cuadro de control MEA de acero al carbono con grado de protecci\u00f3n ip56\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/09\/ip56-carbon-steel-control-panel-MEA-scaled.webp\" alt=\"Cuadro de control MEA de acero al carbono con grado de protecci\u00f3n ip56\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/09\/ip56-carbon-steel-control-panel-MEA-scaled.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/09\/ip56-carbon-steel-control-panel-MEA-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/09\/ip56-carbon-steel-control-panel-MEA-1536x1024.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/09\/ip56-carbon-steel-control-panel-MEA-2048x1365.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/09\/ip56-carbon-steel-control-panel-MEA-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Resuelva las incidencias y autorice el env\u00edo<\/h2><p class=\"p1\">Acuerde las categor\u00edas de autorizaci\u00f3n de env\u00edo para el proyecto. Distinga las no conformidades sin resolver de los trabajos pendientes aceptados y de las comprobaciones asignadas deliberadamente al emplazamiento.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Estado del elemento<\/th><th>Decisi\u00f3n de autorizaci\u00f3n de env\u00edo<\/th><th>Evidencias exigidas<\/th><\/tr><\/thead><tbody><tr><td>Retener el env\u00edo<\/td><td>No autorice el env\u00edo mientras siga sin resolverse un problema de seguridad, una prueba exigida fallida u otra no conformidad que lo impida conforme a los requisitos aplicables.<\/td><td>Correcci\u00f3n, resultados de las pruebas afectadas, registros actualizados y aprobaci\u00f3n del representante autorizado del proyecto.<\/td><\/tr><tr><td>Autorizaci\u00f3n de env\u00edo condicionada<\/td><td>Acepte \u00fanicamente los puntos pendientes especificados que no incumplan los requisitos aplicables de seguridad, certificaci\u00f3n o autorizaci\u00f3n contractual de env\u00edo.<\/td><td>Autorizaci\u00f3n por escrito, parte responsable, fecha de finalizaci\u00f3n, restricciones y evidencias exigidas para el cierre.<\/td><\/tr><tr><td>Verificaci\u00f3n prevista en el emplazamiento<\/td><td>Traslade las comprobaciones que requieran las condiciones acordadas del emplazamiento. No constituyen autom\u00e1ticamente defectos ni permiso para aplazar pruebas de f\u00e1brica fallidas.<\/td><td>Tarea de SAT definida, motivo del aplazamiento, parte responsable e hito de finalizaci\u00f3n.<\/td><\/tr><\/tbody><\/table><\/div><h3>Repita las pruebas afectadas por los cambios antes de cerrar el registro<\/h3><p class=\"p1\">Despu\u00e9s de un cambio en el cableado, un componente, un par\u00e1metro o el software, eval\u00fae el efecto sobre los resultados anteriores y repita las pruebas de los requisitos afectados.<\/p><p class=\"p1\">El alcance puede ir m\u00e1s all\u00e1 del fallo original. Una modificaci\u00f3n en la asignaci\u00f3n de una se\u00f1al puede afectar a una pantalla, una alarma, un enclavamiento y una interfaz externa. Repetir \u00fanicamente el primer paso fallido puede dejar esos efectos sin comprobar.<\/p><p class=\"p1\">Identifique los planos y el software revisados en el registro de repetici\u00f3n de pruebas. El informe de aceptaci\u00f3n final debe corresponder a la configuraci\u00f3n aprobada para el env\u00edo.<\/p><h3>Registre la decisi\u00f3n de autorizaci\u00f3n de env\u00edo efectivamente adoptada<\/h3><p class=\"p1\">Especifique qui\u00e9n puede aprobar el env\u00edo y qu\u00e9 abarca la aprobaci\u00f3n. La firma de un testigo puede confirmar que se ha presenciado una prueba; no deber\u00eda considerarse una autorizaci\u00f3n de env\u00edo salvo que el procedimiento acordado le otorgue ese significado.<\/p><p class=\"p1\">Para los puntos pendientes, sustituya \u00abcorregir en el emplazamiento\u00bb por una acci\u00f3n definida, un responsable, un plazo y evidencias de aceptaci\u00f3n. La autorizaci\u00f3n de env\u00edo condicionada deber\u00eda dejar clara la obligaci\u00f3n pendiente tanto al proveedor como al equipo receptor.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-55438\" title=\"Detalle de un cuadro de control industrial con PLC, cables y rel\u00e9s\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Close-up-of-an-industrial-PLC-control-panel-with-wires-and-relays.webp\" alt=\"Detalle de un cuadro de control industrial con PLC, cables y rel\u00e9s\" width=\"500\" height=\"417\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Close-up-of-an-industrial-PLC-control-panel-with-wires-and-relays.webp 600w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Close-up-of-an-industrial-PLC-control-panel-with-wires-and-relays-500x417.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Close-up-of-an-industrial-PLC-control-panel-with-wires-and-relays-14x12.webp 14w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Verifique la entrega final y el estado para el env\u00edo<\/h2><h3>Entregue registros y software utilizables<\/h3><p class=\"p1\">El expediente de entrega deber\u00eda describir el cuadro que se env\u00eda. Incluya los esquemas conforme a obra aplicables, las relaciones de bornes, la BOM final, los resultados de la FAT, el tratamiento de las incidencias y los documentos de funcionamiento y mantenimiento.<\/p><p class=\"p1\">Cuando se suministre software, entregue los archivos de proyecto del PLC y la HMI, los par\u00e1metros de los variadores, los ajustes de red, la informaci\u00f3n de versiones y las dependencias acordados. Confirme las obligaciones de acceso a los archivos fuente y de licencias conforme al contrato.<\/p><p class=\"p1\">Verifique que los archivos de ingenier\u00eda puedan abrirse con la versi\u00f3n de software especificada. Se trata de una comprobaci\u00f3n b\u00e1sica de usabilidad, que no demuestra una restauraci\u00f3n correcta del sistema. Si se requiere una demostraci\u00f3n de restauraci\u00f3n, acuerde previamente su alcance y sus condiciones de aceptaci\u00f3n.<\/p><p class=\"p1\">Transfiera las credenciales a trav\u00e9s de un canal seguro, sin incluir contrase\u00f1as en fotograf\u00edas ni en informes de amplia distribuci\u00f3n.<\/p><h3>Restablezca la configuraci\u00f3n aprobada<\/h3><p class=\"p1\">Antes del embalaje, compruebe que se hayan retirado los cables de prueba temporales, los puentes, los forzados del PLC y las anulaciones, y que se hayan restablecido los ajustes de prueba, seg\u00fan lo especificado. Identifique y controle cualquier disposici\u00f3n temporal que deba permanecer, incluida la responsabilidad de retirarla.<\/p><p class=\"p1\">Confirme que el hardware, los ajustes y el software finales coincidan con el registro de autorizaci\u00f3n de env\u00edo. Esta comprobaci\u00f3n asegura la correspondencia entre la configuraci\u00f3n aceptada en la FAT y el cuadro que realmente se env\u00eda; no supone repetir todo el programa de pruebas.<\/p><h3>Proteja el cuadro para el transporte<\/h3><p class=\"p1\">Compruebe las tapas, las puertas, los accesorios sueltos, las sujeciones de transporte, los elementos embalados por separado y las instrucciones de manipulaci\u00f3n. Adapte la protecci\u00f3n frente a la humedad y los da\u00f1os al producto, al trayecto y a las condiciones de almacenamiento previstas.<\/p><p class=\"p1\">Registre la lista de embalaje y tome fotograf\u00edas identificables antes del embalaje. Estas respaldan el registro de env\u00edo, pero no sustituyen las evidencias de las pruebas ni la inspecci\u00f3n tras la entrega.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-53484\" title=\"Cuadro de distribuci\u00f3n industrial con botones de control\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons.webp\" alt=\"Cuadro de distribuci\u00f3n industrial con botones de control\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons-500x281.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons-18x10.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Preguntas frecuentes sobre la FAT de cuadros de control<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c7c16e elementor-widget elementor-widget-n-accordion\" data-id=\"2c7c16e\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Acorde\u00f3n. Abra los enlaces con Intro o la barra espaciadora, cierre con Escape y despl\u00e1cese con las teclas de flecha\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4660\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-4660\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 debe incluir una lista de comprobaci\u00f3n FAT de cuadros de control? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4660\" class=\"elementor-element elementor-element-e8424c5 e-con-full e-flex e-con e-child\" data-id=\"e8424c5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-21cc9c0 elementor-widget elementor-widget-text-editor\" data-id=\"21cc9c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Incluya comprobaciones de componentes y caracter\u00edsticas nominales, inspecci\u00f3n mec\u00e1nica, verificaci\u00f3n del cableado, pruebas el\u00e9ctricas aplicables y funciones de control suministradas. En los cuadros programables, a\u00f1ada I\/O, secuencias, alarmas, comunicaciones y recuperaci\u00f3n tras fallos. Registre los criterios de aceptaci\u00f3n, los resultados reales y los puntos pendientes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4661\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4661\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfPueden los compradores presenciar a distancia la FAT de un cuadro de control? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4661\" class=\"elementor-element elementor-element-3706002 e-con-full e-flex e-con e-child\" data-id=\"3706002\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cabfd40 elementor-widget elementor-widget-text-editor\" data-id=\"cabfd40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ed, si la presencia a distancia cumple los requisitos acordados del proyecto. Organice demostraciones en directo, visualizaciones legibles de los instrumentos y acceso a los registros de pruebas. Confirme la identificaci\u00f3n del cuadro y la versi\u00f3n del software e identifique las comprobaciones que requieren un representante presencial.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4662\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4662\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfPuede enviarse un cuadro de control con puntos pendientes de la lista de incidencias de la FAT? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4662\" class=\"elementor-element elementor-element-9bf920d e-con-full e-flex e-con e-child\" data-id=\"9bf920d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a65aa0 elementor-widget elementor-widget-text-editor\" data-id=\"6a65aa0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Solo cuando lo permitan las condiciones autorizadas de env\u00edo. Deben resolverse los problemas de seguridad que impidan el env\u00edo y las pruebas exigidas fallidas. Los puntos pendientes aceptados necesitan aprobaci\u00f3n por escrito, una parte responsable, un plazo y evidencias de cierre. Las pruebas previstas en el emplazamiento deber\u00edan registrarse por separado.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4663\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4663\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfSigue necesitando una FAT un cuadro de control certificado conforme a UL 508A? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4663\" class=\"elementor-element elementor-element-a038781 e-con-full e-flex e-con e-child\" data-id=\"a038781\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fa7afc6 elementor-widget elementor-widget-text-editor\" data-id=\"fa7afc6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La certificaci\u00f3n UL 508A no sustituye a la aceptaci\u00f3n funcional espec\u00edfica del proyecto. La necesidad de una FAT independiente depende del contrato y de los requisitos del proyecto. La certificaci\u00f3n por s\u00ed sola no demuestra que el cuadro suministrado ejecute las secuencias, interfaces y funciones de alarma especificadas por el comprador.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4664\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4664\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 documentos y software deben recibir los compradores despu\u00e9s de la FAT de un cuadro de control? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4664\" class=\"elementor-element elementor-element-499256a e-con-full e-flex e-con e-child\" data-id=\"499256a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7cb7b13 elementor-widget elementor-widget-text-editor\" data-id=\"7cb7b13\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Solicite el informe de la FAT, los planos conforme a obra, la BOM final, los ajustes y el tratamiento de las incidencias. Cuando se incluya software, obtenga los archivos de proyecto del PLC\/HMI, las copias de seguridad, los detalles de las versiones y las dependencias acordados. Confirme los requisitos de acceso a los archivos y de licencias antes del env\u00edo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4665\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4665\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 diferencia hay entre la FAT y la SAT de un cuadro de control? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4665\" class=\"elementor-element elementor-element-e8aed17 e-con-full e-flex e-con e-child\" data-id=\"e8aed17\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c8a692 elementor-widget elementor-widget-text-editor\" data-id=\"0c8a692\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La FAT comprueba el cuadro suministrado en las instalaciones del fabricante, utilizando los equipos y las simulaciones acordados. La SAT verifica el sistema instalado con el cableado de campo, los dispositivos, las redes y las condiciones reales del emplazamiento. Superar la FAT no completa autom\u00e1ticamente las comprobaciones asignadas a la SAT.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cbf49e3 elementor-widget elementor-widget-text-editor\" data-id=\"cbf49e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusi\u00f3n<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-47743\" title=\"Envolvente grande para cuadro de control en una zona ajardinada\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2024\/12\/Large-control-panel-enclosure-in-a-landscaped-area.webp\" alt=\"Envolvente grande para cuadro de control en una zona ajardinada\" width=\"500\" height=\"357\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/12\/Large-control-panel-enclosure-in-a-landscaped-area.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/12\/Large-control-panel-enclosure-in-a-landscaped-area-500x357.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/12\/Large-control-panel-enclosure-in-a-landscaped-area-1536x1097.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/12\/Large-control-panel-enclosure-in-a-landscaped-area-2048x1463.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2024\/12\/Large-control-panel-enclosure-in-a-landscaped-area-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><p class=\"p1\">Una lista de comprobaci\u00f3n FAT de cuadros de control \u00fatil vincula los requisitos aprobados con los resultados de las pruebas y una decisi\u00f3n clara de autorizaci\u00f3n de env\u00edo. Antes del env\u00edo, confirme qu\u00e9 ha superado las pruebas, qu\u00e9 se ha simulado, qu\u00e9 queda para el emplazamiento y si la configuraci\u00f3n entregada coincide con la aceptada. Los registros deber\u00edan ofrecer a los equipos de instalaci\u00f3n y mantenimiento un punto de partida fiable.<\/p><p class=\"p1 translation-block\">Si su proyecto necesita una envolvente a medida para un cuadro de control, <a href=\"https:\/\/www.eabel.com\/es\/contacto\/\" target=\"_blank\" rel=\"noopener\"><strong>contacte con E-abel<\/strong><\/a> e indique la distribuci\u00f3n f\u00edsica de los equipos, el entorno de instalaci\u00f3n, los detalles de las entradas de cables y los requisitos de documentaci\u00f3n. Compartir esta informaci\u00f3n desde el principio ayuda a coordinar las dimensiones, el acceso, los recortes y la construcci\u00f3n de la envolvente con los trabajos de montaje e inspecci\u00f3n previstos. Confirme la disposici\u00f3n final con el fabricante de su cuadro para que la envolvente facilite tanto las comprobaciones en f\u00e1brica como la instalaci\u00f3n pr\u00e1ctica en el emplazamiento.<\/p><h2 class=\"translation-block\"><b>Lecturas relacionadas<\/b><\/h2><p><a href=\"https:\/\/www.eabel.com\/es\/practicas-recomendadas-de-diseno-de-paneles-de-plc-para-la-seguridad\/\" target=\"_blank\" rel=\"noopener noreferrer\">Dise\u00f1o de cuadros con PLC: seguridad, distribuci\u00f3n y buenas pr\u00e1cticas<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/guia-de-gabinetes-para-paneles-de-control-industriales\/\" target=\"_blank\" rel=\"noopener noreferrer\">Gu\u00eda de compra de envolventes para cuadros de control industrial<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/guia-de-accesorios-para-cajas-electricas\/\" target=\"_blank\" rel=\"noopener noreferrer\">Accesorios para envolventes el\u00e9ctricas: tipos, normas y gu\u00eda de selecci\u00f3n<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/normas-de-envolvente-ip-nema-ul\/\" target=\"_blank\" rel=\"noopener noreferrer\">Normas para envolventes el\u00e9ctricas: IP, NEMA y UL<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/es\/nema-12-vs-nema-3r\/\" target=\"_blank\" rel=\"noopener noreferrer\">NEMA 12 y NEMA 3R: elija la clasificaci\u00f3n adecuada<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Utilice esta lista de comprobaci\u00f3n de las pruebas de aceptaci\u00f3n en f\u00e1brica (FAT) de cuadros de control para verificar el cableado, las pruebas el\u00e9ctricas, las funciones del PLC, los registros y la autorizaci\u00f3n de env\u00edo antes de la entrega.<\/p>","protected":false},"author":17,"featured_media":71140,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[80],"tags":[],"class_list":["post-71130","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Use this control panel FAT checklist to verify wiring, electrical tests, PLC functions, records, and shipment release before delivery.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Jie Lian\"\/>\n\t<meta name=\"google-site-verification\" content=\"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"E-Abel -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Control Panel FAT Checklist Before Shipment - E-Abel\" \/>\n\t\t<meta property=\"og:description\" content=\"Use this control panel FAT checklist to verify wiring, electrical tests, PLC functions, records, and shipment release before delivery.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-23T06:36:53+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-27T07:26:37+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Control Panel FAT Checklist Before Shipment - E-Abel\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Use this control panel FAT checklist to verify wiring, electrical tests, PLC functions, records, and shipment release before delivery.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#blogposting\",\"name\":\"Control Panel FAT Checklist Before Shipment - E-Abel\",\"headline\":\"Control Panel FAT Checklist Before Shipment\",\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Control-panel-with-fat-checklist-before-shipment.webp\",\"width\":1448,\"height\":1086,\"caption\":\"Control panel with fat checklist before shipment\"},\"datePublished\":\"2026-10-23T06:36:53+00:00\",\"dateModified\":\"2026-10-27T07:26:37+00:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"E-able\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#listItem\",\"name\":\"Control Panel FAT Checklist Before Shipment\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#listItem\",\"name\":\"E-able\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#listItem\",\"position\":3,\"name\":\"Control Panel FAT Checklist Before Shipment\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#organization\",\"name\":\"E-Abel\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/\",\"telephone\":\"+8618860978683\",\"foundingDate\":\"2008-08-28\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"value\":150},\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/043b221a8891a285b2aaa66333022ef.png\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#organizationLogo\",\"width\":2560,\"height\":1301,\"caption\":\"E-Abel logo form\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/\",\"name\":\"Jie Lian\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Jie Lian\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#webpage\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/\",\"name\":\"Control Panel FAT Checklist Before Shipment - E-Abel\",\"description\":\"Use this control panel FAT checklist to verify wiring, electrical tests, PLC functions, records, and shipment release before delivery.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/author\\\/jay\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Control-panel-with-fat-checklist-before-shipment.webp\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#mainImage\",\"width\":1448,\"height\":1086,\"caption\":\"Control panel with fat checklist before shipment\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/control-panel-fat-checklist\\\/#mainImage\"},\"datePublished\":\"2026-10-23T06:36:53+00:00\",\"dateModified\":\"2026-10-27T07:26:37+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/\",\"name\":\"E-Abel\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Control Panel FAT Checklist Before Shipment - E-Abel<\/title>\n\n","aioseo_head_json":{"title":"Lista de comprobaci\u00f3n FAT de cuadros de control antes del env\u00edo - E-Abel","description":"Utilice esta lista de comprobaci\u00f3n de las pruebas de aceptaci\u00f3n en f\u00e1brica (FAT) de cuadros de control para verificar el cableado, las pruebas el\u00e9ctricas, las funciones del PLC, los registros y la autorizaci\u00f3n de env\u00edo antes de la entrega.","canonical_url":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"google-site-verification":"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#blogposting","name":"Control Panel FAT Checklist Before Shipment - E-Abel","headline":"Control Panel FAT Checklist Before Shipment","author":{"@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author"},"publisher":{"@id":"https:\/\/www.eabel.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp","width":1448,"height":1086,"caption":"Control panel with fat checklist before shipment"},"datePublished":"2026-10-23T06:36:53+00:00","dateModified":"2026-10-27T07:26:37+00:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#webpage"},"isPartOf":{"@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/#listItem","position":1,"name":"E-able","item":"https:\/\/www.eabel.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/www.eabel.com\/es\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#listItem","name":"Control Panel FAT Checklist Before Shipment"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/#listItem","name":"E-able"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#listItem","position":3,"name":"Control Panel FAT Checklist Before Shipment","previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/es\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/www.eabel.com\/es\/#organization","name":"E-Abel","url":"https:\/\/www.eabel.com\/es\/","telephone":"+8618860978683","foundingDate":"2008-08-28","numberOfEmployees":{"@type":"QuantitativeValue","value":150},"logo":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2022\/05\/043b221a8891a285b2aaa66333022ef.png","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#organizationLogo","width":2560,"height":1301,"caption":"E-Abel logo form"},"image":{"@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author","url":"https:\/\/www.eabel.com\/es\/author\/jay\/","name":"Jie Lian","image":{"@type":"ImageObject","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g","width":96,"height":96,"caption":"Jie Lian"}},{"@type":"WebPage","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#webpage","url":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/","name":"Control Panel FAT Checklist Before Shipment - E-Abel","description":"Use this control panel FAT checklist to verify wiring, electrical tests, PLC functions, records, and shipment release before delivery.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.eabel.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#breadcrumblist"},"author":{"@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author"},"creator":{"@id":"https:\/\/www.eabel.com\/es\/author\/jay\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp","@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#mainImage","width":1448,"height":1086,"caption":"Control panel with fat checklist before shipment"},"primaryImageOfPage":{"@id":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/#mainImage"},"datePublished":"2026-10-23T06:36:53+00:00","dateModified":"2026-10-27T07:26:37+00:00"},{"@type":"WebSite","@id":"https:\/\/www.eabel.com\/es\/#website","url":"https:\/\/www.eabel.com\/es\/","name":"E-Abel","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.eabel.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"E-Abel -","og:type":"article","og:title":"Control Panel FAT Checklist Before Shipment - E-Abel","og:description":"Use this control panel FAT checklist to verify wiring, electrical tests, PLC functions, records, and shipment release before delivery.","og:url":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/","og:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp","og:image:secure_url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp","og:image:width":1448,"og:image:height":1086,"article:published_time":"2026-10-23T06:36:53+00:00","article:modified_time":"2026-10-27T07:26:37+00:00","twitter:card":"summary_large_image","twitter:title":"Control Panel FAT Checklist Before Shipment - E-Abel","twitter:description":"Use this control panel FAT checklist to verify wiring, electrical tests, PLC functions, records, and shipment release before delivery.","twitter:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Control-panel-with-fat-checklist-before-shipment.webp"},"aioseo_meta_data":{"post_id":"71130","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":true,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-10-27 07:28:14","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-10-23 05:18:36","updated":"2026-10-27 08:02:00","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/es\/\" title=\"E-able\">E-able<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/es\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tControl Panel FAT Checklist Before Shipment\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"E-able","link":"https:\/\/www.eabel.com\/es\/"},{"label":"Blog","link":"https:\/\/www.eabel.com\/es\/category\/blog\/"},{"label":"Control Panel FAT Checklist Before Shipment","link":"https:\/\/www.eabel.com\/es\/control-panel-fat-checklist\/"}],"_links":{"self":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/posts\/71130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/comments?post=71130"}],"version-history":[{"count":0,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/posts\/71130\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/media\/71140"}],"wp:attachment":[{"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/media?parent=71130"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/categories?post=71130"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eabel.com\/es\/wp-json\/wp\/v2\/tags?post=71130"}],"curies":[{"name":"Gracias","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}