{"id":71174,"date":"2026-10-29T07:51:25","date_gmt":"2026-10-29T07:51:25","guid":{"rendered":"https:\/\/www.eabel.com\/?p=71174"},"modified":"2026-11-03T02:41:28","modified_gmt":"2026-11-03T02:41:28","slug":"sccr-industrieller-steuerschraenke","status":"publish","type":"post","link":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/","title":{"rendered":"So bestimmen Sie den Kurzschlussbemessungswert (SCCR) eines industriellen Steuerschaltschranks"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"71174\" class=\"elementor elementor-71174\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a50b80 e-flex e-con-boxed e-con e-parent\" data-id=\"8a50b80\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba82a7 elementor-widget elementor-widget-text-editor\" data-id=\"6ba82a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">Um den Bemessungswert der Kurzschlussstromfestigkeit (SCCR) eines industriellen Steuerschranks zu bestimmen, bewerten Sie die Komponenten seiner Leistungsstromkreise, die Schutzeinrichtungen und alle zul\u00e4ssigen Kombinationen oder M\u00f6glichkeiten zur Strombegrenzung im Einspeisestromkreis. Der niedrigste nach dieser Bewertung anwendbare Grenzwert bestimmt die SCCR des Steuerschranks. UL 508A Supplement SB bietet ein anerkanntes analytisches Verfahren; eine Kurzschlusspr\u00fcfung der Schaltger\u00e4tekombination ist ein weiterer Weg.<\/p>\n<p class=\"p1\">Dieser Leitfaden behandelt g\u00e4ngige industrielle Niederspannungs-Steuerschr\u00e4nke f\u00fcr Wechselspannung in US-Projekten. Ein qualifizierter Planer oder Bewerter muss die Anforderungen anwenden, die f\u00fcr die tats\u00e4chliche Schaltger\u00e4tekombination und Installation gelten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eee58d2 e-flex e-con-boxed e-con e-parent\" data-id=\"eee58d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7e6e4db elementor-widget elementor-widget-text-editor\" data-id=\"7e6e4db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Das Wichtigste auf einen Blick<\/h2>\n<ul><li>Ein hohes Ausschaltverm\u00f6gen des Hauptleistungsschalters belegt nicht die SCCR des Steuerschranks.<\/li><li>Bemessungswerte gelten bei bestimmten Spannungen und k\u00f6nnen von genau festgelegten Schutzeinrichtungen und Installationsbedingungen abh\u00e4ngen.<\/li><li>F\u00fcr die SCCR des Steuerschranks und den am Standort zu erwartenden Kurzschlussstrom sind getrennte Nachweise erforderlich.<\/li><li>\u00c4nderungen der Konfiguration und neue Einspeisungsanordnungen erfordern eine \u00dcberpr\u00fcfung der betroffenen Bemessungswerte oder Installationsannahmen.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d3aed5f e-flex e-con-boxed e-con e-parent\" data-id=\"d3aed5f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-12217ec elementor-widget elementor-widget-text-editor\" data-id=\"12217ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Was SCCR bei einem industriellen Steuerschrank bedeutet<\/h2><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Begriff<\/th><th>Was er beschreibt<\/th><th>Wo Sie die Angabe finden<\/th><\/tr><\/thead><tbody><tr><td>SCCR des Steuerschranks<\/td><td>Die durch den Bemessungswert ausgewiesene Kurzschlussfestigkeit der Schaltger\u00e4tekombination bei der angegebenen Spannung und unter den festgelegten Bedingungen.<\/td><td>Bewertungsunterlagen und Kennzeichnung des Steuerschranks.<\/td><\/tr><tr><td>Bemessungsausschaltverm\u00f6gen in Ampere (AIC)<\/td><td>Die F\u00e4higkeit einer Schutzeinrichtung, einen Fehlerstrom bei ihrer Bemessungsspannung zu unterbrechen.<\/td><td>Technische Daten der Sicherung oder des Leistungsschalters.<\/td><\/tr><tr><td>Verf\u00fcgbarer Kurzschlussstrom<\/td><td>Der am Einbauort zu erwartende Kurzschlussstrom. F\u00fcr Vergleiche bei Wechselstrom ist der zutreffende symmetrische Effektivwert (RMS) zu verwenden.<\/td><td>Eine Kurzschlussstudie f\u00fcr den Standort oder eine andere anerkannte Berechnung.<\/td><\/tr><tr><td>Bemessungsstrom des Steuerschranks<\/td><td>Der Bemessungsstrom des Steuerschranks im normalen Betrieb.<\/td><td>Planungsunterlagen und Typenschild des Steuerschranks.<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">Bei der SCCR-Pr\u00fcfung im Rahmen der Installationskontrolle muss die SCCR des Steuerschranks mindestens so hoch sein wie der zu erwartende Kurzschlussstrom; zugleich m\u00fcssen die erforderlichen Spannungs- und Schutzbedingungen erf\u00fcllt sein. Dieser Vergleich bestimmt weder die einwirkende Energie eines St\u00f6rlichtbogens noch ersetzt er andere Installationspr\u00fcfungen.<\/p><p class=\"p1\">Eine Berechnung des Kurzschlussstroms am Transformator allein kann die SCCR des Steuerschranks nicht belegen; sie ber\u00fccksichtigt die Bemessungswerte der vollst\u00e4ndigen Schaltger\u00e4tekombination nicht.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-65949\" title=\"Industrielle elektrische Steuerschr\u00e4nke mit ge\u00f6ffneten Abdeckungen\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-scaled.webp\" alt=\"Industrielle elektrische Steuerschr\u00e4nke mit ge\u00f6ffneten Abdeckungen\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-scaled.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-1536x1024.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-2048x1365.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/02\/Industrial-electrical-control-cabinets-with-open-panels-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Die SCCR des Steuerschranks nach UL 508A bestimmen<\/h2><h3>Versorgungsbedingungen und Projektanforderungen best\u00e4tigen<\/h3><p class=\"p1\">Best\u00e4tigen Sie die Betriebsspannung, die Phasen, die Erdungsanordnung, die Versorgungsanschl\u00fcsse und die erforderliche SCCR des Steuerschranks. Pr\u00fcfen Sie die Spannungsgrenzen sowohl zwischen den Au\u00dfenleitern als auch zwischen Au\u00dfenleiter und Erde; ein Leistungsschalter mit der Angabe 480Y\/277 V ist nicht f\u00fcr jedes 480-V-System geeignet. Ermitteln Sie separate Einspeisungen oder Ersatzversorgungen, die diese Bedingungen ver\u00e4ndern.<\/p><p class=\"p1\">Beschaffen Sie Angaben zum Kurzschlussstrom am Anschlusspunkt des Steuerschranks. Ein Wert am Transformator des Versorgungsunternehmens gilt nicht automatisch auch an den Anschlussklemmen des Steuerschranks; die dazwischenliegenden Leiter und weitere Systembedingungen sind zu ber\u00fccksichtigen. Der Elektroplaner des Projekts sollte diese Angaben bereitstellen oder \u00fcberpr\u00fcfen.<\/p><p class=\"p1 translation-block\">Pr\u00fcfen Sie die f\u00fcr das Projekt \u00fcbernommene Elektroinstallationsvorschrift und die zutreffenden <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL508A\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Anforderungen aus UL 508A<\/b><\/a>. Artikel 409 des NEC behandelt die Kennzeichnung und Installation industrieller Steuerschr\u00e4nke. Die \u00dcberarbeitung von UL 508A vom Juni 2025 enth\u00e4lt SCCR-bezogene \u00c4nderungen. Pr\u00fcfen Sie daher \u00e4ltere Tabellen und Ausnahmen, bevor Sie diese verwenden.<\/p><p class=\"p1\">Auch wenn keine Kurzschlussstromdaten f\u00fcr den Standort vorliegen, l\u00e4sst sich die SCCR des Steuerschranks bestimmen. Ob die Installation geeignet ist, bleibt jedoch unbest\u00e4tigt, bis der gesonderte Vergleich abgeschlossen ist.<\/p><h3>Die relevanten Komponenten der Leistungsstromkreise erfassen<\/h3><p class=\"p1\">Beginnen Sie mit den freigegebenen Zeichnungen und einer St\u00fcckliste (BOM). Ein Einspeisestromkreis versorgt die Schutzeinrichtungen der Abzweigstromkreise; ein Abzweigstromkreis verl\u00e4uft von seiner letzten Abzweig-Schutzeinrichtung weiter zum Verbraucher. Diese Grenzen sind f\u00fcr die Bewertung des Schutzes entscheidend.<\/p><p class=\"p1 translation-block\">Verfolgen Sie die relevanten <a href=\"https:\/\/www.eabel.com\/de\/komponenten-des-elektrischen-bedienfelds\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Komponenten des Steuerschranks<\/b><\/a>, darunter Trennschalter, Sicherungshalter, Verteilerbl\u00f6cke, Sammelschienen, Abzweig-Schutzeinrichtungen, Sch\u00fctze, \u00dcberlastrelais, Antriebsger\u00e4te, \u00dcberspannungsschutzger\u00e4te und Klemmen der Leistungsstromkreise. Beziehen Sie alternative Strompfade und Bypasspfade ein, die zur gelieferten Ausf\u00fchrung geh\u00f6ren.<\/p><p class=\"p1\">Ordnen Sie Stromkreise nach ihrer Funktion ein, nicht allein nach ihrer Spannung. Ein Steuerschrank, der ausschlie\u00dflich Steuerstromkreise enth\u00e4lt, kann von der SCCR-Kennzeichnung ausgenommen sein; eine 24-V-Angabe allein belegt diese Ausnahme nicht. Pr\u00fcfen Sie den anwendbaren \u00dcberstromschutz f\u00fcr die Einspeisung der Steuerstromkreise, einschlie\u00dflich der Prim\u00e4rseiten von Steuertransformatoren und Netzteilen.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-62688\" title=\"Industrielle Schr\u00e4nke mit zweilagigem Aufbau und Bedienfeldern\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels.webp\" alt=\"Industrielle Schr\u00e4nke mit zweilagigem Aufbau und Bedienfeldern\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-double-layer-cabinets-with-control-panels-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Einzel- und Kombinationsbemessungswerte feststellen<\/h3><p class=\"p1\">Erfassen Sie f\u00fcr jede relevante Komponente die Katalognummer, die zutreffende Spannung, den Bemessungswert, den erforderlichen Schutz und die Nachweisquelle. Nehmen Sie auch das Ausschaltverm\u00f6gen von Sicherungen und Leistungsschaltern auf. Verwenden Sie Produktkennzeichnungen, Herstelleranweisungen und die einschl\u00e4gigen Zertifizierungsunterlagen.<\/p><p class=\"p1\">Soweit zul\u00e4ssig, enth\u00e4lt Tabelle SB4.1 Standardbemessungswerte f\u00fcr bestimmte Komponentenkategorien. Sie ist kein allgemeiner Ersatz f\u00fcr fehlende Angaben zu nicht identifizierten Ger\u00e4ten. Fehlende Informationen rechtfertigen es nicht, dem gesamten Steuerschrank pauschal eine SCCR von 5 kA zuzuweisen.<\/p><p class=\"p1 translation-block\">Der Bemessungswert einer Einzelkomponente und der einer gepr\u00fcften Kombination sind unterschiedliche Nachweisformen. Eine Kombination kann einen h\u00f6heren anwendbaren Bemessungswert begr\u00fcnden, wenn genau die vorgeschriebenen Ger\u00e4te und Bedingungen eingehalten werden. Ziehen Sie die <a href=\"https:\/\/www.ul.com\/resources\/short-circuit-current-ratings-combination-motor-controller-components\" target=\"_blank\" rel=\"noopener noreferrer\"><b>UL-Nachweise f\u00fcr Motorsteuerger\u00e4te-Kombinationen<\/b><\/a> sowie die Dokumentation des jeweiligen Herstellers heran.<\/p><p class=\"p1 translation-block\">Pr\u00fcfen Sie die vorgeschriebene Schutzeinrichtung, ihren maximalen Bemessungsstrom, die Sicherungsklasse oder die genaue Leistungsschalterbezeichnung, die Spannung sowie alle Verdrahtungs- oder Installationsbedingungen. Manche Kombinationen schreiben ein Mindestvolumen des Geh\u00e4uses oder Mindestabst\u00e4nde zwischen Komponenten vor. Wenn Sie <a href=\"https:\/\/www.eabel.com\/de\/gehause\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Elektrogeh\u00e4use von E-Abel<\/b><\/a> pr\u00fcfen, best\u00e4tigen Sie, dass die Innenabmessungen und die Montageanordnung des gew\u00e4hlten Modells die festgelegten Bedingungen der Kombination erf\u00fcllen.<\/p><p class=\"p1\">Der Bemessungswert einer Kombination gilt nur f\u00fcr die darin bezeichneten Komponenten. Bewerten Sie zus\u00e4tzliche Klemmen oder Verteilerbl\u00f6cke gesondert. F\u00fcr ein Ersatzger\u00e4t mit demselben Bemessungsstrom ist eine eigene dokumentierte Grundlage f\u00fcr seine Anerkennung erforderlich.<\/p><h3>Zul\u00e4ssige Strombegrenzung im Einspeisestromkreis bewerten<\/h3><p class=\"p1\">Supplement SB4.3 behandelt die anwendbaren Verfahren zur Strombegrenzung im Einspeisestromkreis. Je nach Anordnung k\u00f6nnen dabei ein Leistungstransformator mit galvanisch getrennter Sekund\u00e4rseite, bestimmte Sicherungen oder ein als strombegrenzend ausgewiesener, gelisteter Leistungsschalter zum Einsatz kommen. Wenden Sie das zutreffende Verfahren mit seinen Bedingungen an; gehen Sie nicht davon aus, dass jede Schutzeinrichtung daf\u00fcr geeignet ist.<\/p><p class=\"p1\">Ein hohes Ausschaltverm\u00f6gen belegt keine Strombegrenzung. Pr\u00fcfen Sie die erforderlichen Leistungsdaten und verfolgen Sie, welche Komponenten den zul\u00e4ssigen Schutz erhalten. Komponenten auf der Netzseite des strombegrenzenden Elements ben\u00f6tigen weiterhin eine eigene zutreffende Bewertung.<\/p><p class=\"p1\">Wenn das Verfahren den Scheitelwert des Durchlassstroms verwendet, wenden Sie den daf\u00fcr vorgeschriebenen Vergleich an. Ein Scheitelwert ist kein neu berechneter Effektivwert (RMS) des zu erwartenden Kurzschlussstroms. Die Strombegrenzung im Einspeisestromkreis erh\u00f6ht auch nicht automatisch das Ausschaltverm\u00f6gen eines nachgeschalteten Leistungsschalters.<\/p><p class=\"p1\">Verwechseln Sie eine gepr\u00fcfte Motorsteuerger\u00e4te-Kombination nicht mit dem Bemessungswert einer Schutzger\u00e4te-Reihenschaltung. Dieser Wert gilt f\u00fcr bestimmte, zusammenwirkende Schutzeinrichtungen; er legt nicht die Bemessungswerte s\u00e4mtlicher anderer Komponenten der Leistungsstromkreise fest. Eine entsprechende Bemessungstabelle f\u00fcr Stromkreisverteiler ist kein pauschaler Nachweis f\u00fcr einen industriellen Steuerschrank.<\/p><p class=\"p1\">Die Betriebsstrombegrenzung eines Frequenzumrichters ersetzt keine Bewertung der Kurzschlussstrombegrenzung im Fehlerfall. Halten Sie bei Antriebsger\u00e4ten und anderen Ger\u00e4ten mit vorgeschriebenem Kurzschlussschutz die ver\u00f6ffentlichte Schutzanordnung ein und pr\u00fcfen Sie die zutreffenden Einschr\u00e4nkungen aus Supplement SB, bevor Sie einen Bemessungswert aufgrund der Einspeisung anpassen.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-62427\" title=\"Industrielle elektrische Steuerfelder mit Schaltern und Messger\u00e4ten\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters.webp\" alt=\"Industrielle elektrische Steuerfelder mit Schaltern und Messger\u00e4ten\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters-500x281.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/12\/Industrial-electrical-control-panels-with-switches-and-meters-18x10.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Den Gesamtbemessungswert festlegen und die Installation pr\u00fcfen<\/h3><p class=\"p1\">Bestimmen Sie den anwendbaren Grenzwert jedes Abzweigstromkreises, nachdem g\u00fcltige Kombinationen und zul\u00e4ssige Anpassungen bewertet wurden. Behalten Sie alle durch die Abzweig-Schutzeinrichtungen vorgegebenen Grenzen bei. Ber\u00fccksichtigen Sie anschlie\u00dfend die Komponenten und Schutzeinrichtungen des Einspeisestromkreises, um die SCCR des gesamten Steuerschranks zu bestimmen.<\/p><p class=\"p1\">Ma\u00dfgebend ist der niedrigste anwendbare Grenzwert nach Anwendung der zul\u00e4ssigen Bewertungsverfahren. Das ist nicht zwingend die kleinste auf einer Einzelkomponente aufgedruckte Zahl. Die Bemessungswerte der Komponenten werden auch nicht addiert.<\/p><p class=\"p1\">Vergleichen Sie das Ergebnis mit dem zu erwartenden Kurzschlussstrom am Anschlusspunkt des Steuerschranks. Der Bemessungswert muss bei der Betriebsspannung und mit den installierten Schutzeinrichtungen gelten. Pr\u00fcfen Sie jeden Versorgungsanschluss und jede relevante Konfiguration, einschlie\u00dflich der Ersatzversorgungen.<\/p><p class=\"p1\">Ist der Bemessungswert zu niedrig, ermitteln Sie den begrenzenden Stromkreis oder die begrenzende Komponente, bevor Sie Ersatz bestellen. Ziehen Sie eine Komponente oder Kombination mit dokumentiertem h\u00f6herem Bemessungswert, eine zul\u00e4ssige Schutzanordnung oder eine geeignete Pr\u00fcfung der Schaltger\u00e4tekombination in Betracht. Bewerten Sie die betroffene Konfiguration erneut, bevor Sie einen neuen Bemessungswert zuweisen.<\/p><h3>Rechenbeispiel: den begrenzenden Bemessungswert finden<\/h3><p class=\"p1\">Betrachten Sie einen beispielhaften Steuerschrank f\u00fcr 480 V AC an einem Standort mit einem zu erwartenden Kurzschlussstrom von 35 kA. Seine Hauptschutzeinrichtung hat ein Ausschaltverm\u00f6gen von 100 kA. F\u00fcr Abzweig A ist ein Bemessungswert von 65 kA nachgewiesen. Alle \u00fcbrigen relevanten Grenzwerte betragen mindestens 65 kA, mit Ausnahme der nachfolgend aufgef\u00fchrten Positionen.<\/p><p class=\"p1\">Eine Erh\u00f6hung des Bemessungswerts durch Strombegrenzung im Einspeisestromkreis wird nicht angenommen. Es wird vorausgesetzt, dass alle Bemessungswerte bei der angegebenen Spannung gelten und die erforderlichen Schutz- und Installationsbedingungen erf\u00fcllt sind.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Bewertete Konfiguration<\/th><th>Bemessungswert von Abzweig B<\/th><th>Verteilungskomponente im Einspeisestromkreis<\/th><th>Gesamtergebnis f\u00fcr den Steuerschrank<\/th><\/tr><\/thead><tbody><tr><td>Urspr\u00fcnglicher Steuerschrank<\/td><td>5 kA<\/td><td>10 kA<\/td><td>5 kA: unter der Standortanforderung von 35 kA.<\/td><\/tr><tr><td>Aufr\u00fcstung von Abzweig B nachgewiesen<\/td><td>65 kA<\/td><td>10 kA<\/td><td>10 kA: weiterhin unter der Standortanforderung.<\/td><\/tr><tr><td>Aufr\u00fcstung des Einspeisestromkreises ebenfalls nachgewiesen<\/td><td>65 kA<\/td><td>65 kA<\/td><td>65 kA: erf\u00fcllt die Kurzschlussstromanforderung des Beispiels.<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">Jede nachgewiesene Aufr\u00fcstung erfordert Belege f\u00fcr die Bemessungswerte der tats\u00e4chlich eingesetzten Ger\u00e4te und die Installationsbedingungen; ein h\u00f6herer Bemessungsstrom f\u00fcr den Normalbetrieb allein reicht nicht aus. Die letzte Zeile zeigt, dass die SCCR-Anforderung in diesem Beispiel erf\u00fcllt wird. Sie belegt weder eine UL-Zertifizierung noch die Einhaltung s\u00e4mtlicher Installationsanforderungen.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-55441\" title=\"Industrieller SPS-Steuerschrank mit Bel\u00fcftung und Komponenten\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-scaled.webp\" alt=\"Industrieller SPS-Steuerschrank mit Bel\u00fcftung und Komponenten\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-scaled.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-1536x1152.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-2048x1536.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/08\/Industrial-PLC-control-panel-with-air-ventilation-and-components-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Die nachgewiesene SCCR dokumentieren und aktuell halten<\/h2><p class=\"p1\">Ein belastbarer Bemessungswert muss auf den tats\u00e4chlich gelieferten Steuerschrank zur\u00fcckf\u00fchrbar sein. F\u00fchren Sie einen einheitlichen, revisionsgelenkten Unterlagensatz mit:<\/p><ul><li>dem Bewertungsblatt, in dem jeder relevante Stromkreis mit seinem Bemessungsnachweis verkn\u00fcpft ist.<\/li><li>den freigegebenen Revisionsst\u00e4nden der Zeichnungen und der St\u00fcckliste (BOM), die die gelieferte Konfiguration eindeutig beschreiben.<\/li><li>der SCCR-Kennzeichnung des Steuerschranks einschlie\u00dflich der zutreffenden H\u00f6chstspannung und der erforderlichen Angaben zum vor Ort bereitzustellenden Schutz.<\/li><li>dem zu erwartenden Kurzschlussstrom am Steuerschrank, dem Berechnungsdatum, dem Verweis auf die zugrunde liegende Berechnung oder Studie und der bewerteten Einspeisungskonfiguration.<\/li><\/ul><p class=\"p1 translation-block\">Wenn ein Bemessungswert von einem vor Ort bereitzustellenden Schutz abh\u00e4ngt, legen Sie das erforderliche Ger\u00e4t sowie die Zust\u00e4ndigkeit f\u00fcr Lieferung, Installation und \u00dcberpr\u00fcfung fest. Die <a href=\"https:\/\/www.ul.com\/resources\/determining-short-circuit-current-rating-sccr-machinery\" target=\"_blank\" rel=\"noopener noreferrer\"><b>SCCR-Hinweise von UL<\/b><\/a> best\u00e4tigen, dass strombegrenzende Sicherungen in einem separaten Geh\u00e4use installiert sein k\u00f6nnen, das den Steuerschrank speist. \u00dcbernehmen Sie diese Anforderungen in die Einkaufs- und Installationsunterlagen und pr\u00fcfen Sie anschlie\u00dfend die installierte Anordnung.<\/p><p class=\"p1 translation-block\">Unterscheiden Sie \u00c4nderungen am Produkt von \u00c4nderungen am Standort. Der Austausch einer relevanten Komponente, \u00c4nderungen an der Verdrahtung oder der <a href=\"https:\/\/www.eabel.com\/de\/leitfaden-fur-industrielle-schalttafelgehause\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Anordnung im Geh\u00e4use<\/b><\/a> sowie Abweichungen von einer vorgeschriebenen Installationsbedingung erfordern eine \u00dcberpr\u00fcfung der Bemessungsnachweise. Bei einem anderen Transformator, einer ge\u00e4nderten Einspeisung oder einem anderen Einbauort m\u00fcssen der zu erwartende Kurzschlussstrom und die Kompatibilit\u00e4t erneut gepr\u00fcft werden. Die nachgewiesene SCCR des Steuerschranks \u00e4ndert sich nicht automatisch allein durch einen Standortwechsel.<\/p><p class=\"p1 translation-block\">Bitten Sie bei einem bestehenden Steuerschrank ohne Bemessungsunterlagen den Hersteller oder einen qualifizierten Bewerter, die tats\u00e4chlich ausgef\u00fchrte Konfiguration zu bewerten, bevor eine SCCR zugewiesen wird. Eine routinem\u00e4\u00dfige <a href=\"https:\/\/www.eabel.com\/de\/fat-checkliste-steuerschaltschrank\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Werksabnahmepr\u00fcfung<\/b><\/a> oder Isolationspr\u00fcfung belegt keine Kurzschlussfestigkeit. Ebenso belegt ein UL-zertifiziertes Geh\u00e4use keine Zertifizierung des fertiggestellten Steuerschranks.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-60612\" title=\"Industrielle Steuerschaltger\u00e4tekombination mit UL-Listing von E Abel in ge\u00f6ffneter Ansicht\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view.webp\" alt=\"Industrielle Steuerschaltger\u00e4tekombination mit UL-Listing von E Abel in ge\u00f6ffneter Ansicht\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/11\/UL-listed-industrial-control-panel-by-E-Abel-open-view-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>H\u00e4ufige Fragen zur SCCR von Steuerschr\u00e4nken<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14a7ee2 elementor-widget elementor-widget-n-accordion\" data-id=\"14a7ee2\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Akkordeon. Links mit der Eingabe- oder Leertaste \u00f6ffnen, mit Escape schlie\u00dfen und mit den Pfeiltasten navigieren\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2160\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2160\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Soll ich einen Steuerschrank mit einer SCCR von 65 kA oder 100 kA bestellen? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2160\" class=\"elementor-element elementor-element-f1ef89d e-con-full e-flex e-con e-child\" data-id=\"f1ef89d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-609334b elementor-widget elementor-widget-text-editor\" data-id=\"609334b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>W\u00e4hlen Sie einen Bemessungswert, der den am Standort dokumentierten zu erwartenden Kurzschlussstrom bei der Betriebsspannung abdeckt. Keiner der beiden Werte ist eine allgemeing\u00fcltige Anforderung. Ber\u00fccksichtigen Sie bei der Festlegung der Einkaufsspezifikation geplante Aufr\u00fcstungen des Transformators oder der Verteilung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2161\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2161\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> K\u00f6nnen die IEC-Werte Icu oder Ics die SCCR eines Steuerschranks nach UL 508A ersetzen? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2161\" class=\"elementor-element elementor-element-e2d87f7 e-con-full e-flex e-con e-child\" data-id=\"e2d87f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-64e7f43 elementor-widget elementor-widget-text-editor\" data-id=\"64e7f43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Icu und Ics beschreiben das Verhalten eines Leistungsschalters nach IEC-Anforderungen. Sie belegen nicht die SCCR des gesamten Steuerschranks; diese muss mit einem anerkannten Verfahren zur Bewertung der Schaltger\u00e4tekombination ermittelt werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2162\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2162\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Ben\u00f6tigt jeder baugleiche Steuerschrank eine zerst\u00f6rende SCCR-Pr\u00fcfung? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2162\" class=\"elementor-element elementor-element-fcc38e9 e-con-full e-flex e-con e-child\" data-id=\"fcc38e9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-133a35d elementor-widget elementor-widget-text-editor\" data-id=\"133a35d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. UL 508A Supplement SB bietet ein analytisches Verfahren. Jeder gelieferte Steuerschrank muss hinsichtlich Komponenten, Schutz und Aufbau den Grundlagen seines Bemessungswerts entsprechen. Die geltenden Anforderungen an Fertigungspr\u00fcfungen und Zertifizierung bleiben bestehen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2163\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2163\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Gilt die SCCR eines Steuerschranks f\u00fcr die gesamte Maschine? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2163\" class=\"elementor-element elementor-element-0e5c893 e-con-full e-flex e-con e-child\" data-id=\"0e5c893\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-33c5c0d elementor-widget elementor-widget-text-editor\" data-id=\"33c5c0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nicht automatisch. Leistungsstromkreise au\u00dferhalb des bewerteten Steuerschranks k\u00f6nnen den Bemessungswert der gesamten Maschine beeinflussen. Fordern Sie eine Best\u00e4tigung der SCCR der vollst\u00e4ndigen Maschine sowie des Bemessungswerts f\u00fcr jeden separaten Versorgungsanschluss an.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2164\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2164\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kann ein importierter Steuerschrank nach der Lieferung f\u00fcr die Installation in den USA bewertet werden? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2164\" class=\"elementor-element elementor-element-6128609 e-con-full e-flex e-con e-child\" data-id=\"6128609\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6408da4 elementor-widget elementor-widget-text-editor\" data-id=\"6408da4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ja. Eine von der \u00f6rtlich zust\u00e4ndigen Beh\u00f6rde anerkannte Stelle f\u00fcr Vor-Ort-Bewertungen kann den konkreten Steuerschrank bewerten und erforderliche \u00c4nderungen ermitteln. Veranlassen Sie dies vor dem Einschalten der Versorgung; eine standortbezogene Bewertung gilt nicht automatisch f\u00fcr andere Einheiten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2165\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2165\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kann ein Steuerschrank nach einem Kurzschluss wiederverwendet werden, wenn der Kurzschlussstrom unter seinem SCCR-Wert lag? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2165\" class=\"elementor-element elementor-element-dac26ff e-con-full e-flex e-con e-child\" data-id=\"dac26ff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f59ddc5 elementor-widget elementor-widget-text-editor\" data-id=\"f59ddc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div><div><div><div><div><div><div><div><div><div><div><div><div><div><div><div><div><p>Gehen Sie nicht davon aus. Die SCCR-Kennzeichnung allein best\u00e4tigt nicht den Zustand der Ger\u00e4te nach einem Fehler. Qualifizierte Elektrofachkr\u00e4fte sollten die betroffenen Ger\u00e4te vor dem Wiedereinschalten \u00fcberpr\u00fcfen und die Reparatur- oder Austauschvorgaben des Herstellers befolgen.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb3f5d9 elementor-widget elementor-widget-text-editor\" data-id=\"cb3f5d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fazit<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-53484\" title=\"Industrielle Verteilertafel mit Bedientasten\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons.webp\" alt=\"Industrielle Verteilertafel mit Bedientasten\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons-500x281.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/06\/Industrial-distribution-panel-with-control-buttons-18x10.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><p class=\"p1\">Die SCCR eines industriellen Steuerschranks st\u00fctzt sich auf seine Stromkreisauslegung, seine Schutzanordnungen und die dokumentierten Bedingungen der Bemessungswerte. Best\u00e4tigen Sie vor der Abnahme des Steuerschranks, dass sein Bemessungswert bei der Betriebsspannung gilt und mindestens dem am Einbauort zu erwartenden Kurzschlussstrom entspricht. Schlie\u00dfen Sie Nachweisl\u00fccken, bevor Sie den SCCR-Vergleich freigeben.<\/p><p class=\"p1 translation-block\">Nutzen Sie diese Bedingungen bei einem neuen Steuerschrank oder einer Neukonstruktion zur Festlegung der Geh\u00e4usespezifikation. \u00dcbermitteln Sie die Komponentenanordnung, die angestrebte SCCR, die Spannung, den erforderlichen Schutz sowie vorgegebene Volumen oder Abst\u00e4nde. Nennen Sie auch die Anforderungen an Kabeleinf\u00fchrungen und den Zugang f\u00fcr Wartungsarbeiten. <a href=\"https:\/\/www.eabel.com\/de\/kontakt\/\" target=\"_blank\" rel=\"noopener\"><strong>Kontaktieren Sie uns<\/strong><\/a>, um eine Geh\u00e4useanordnung zu besprechen, die Ihre gew\u00e4hlten Ger\u00e4te und deren dokumentierte Installationsanforderungen ber\u00fccksichtigt.<\/p><h2 class=\"translation-block\"><b>Weiterf\u00fchrende Artikel<\/b><\/h2><p><a href=\"https:\/\/www.eabel.com\/de\/vergleich-ul-508a-ul-67-ul-891\/\" target=\"_blank\" rel=\"noopener noreferrer\">UL 508A, UL 67 und UL 891: Die wichtigsten Unterschiede<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/zuleitung-vs-endstromkreis-nec-dimensionierung-schutz\/\" target=\"_blank\" rel=\"noopener noreferrer\">Speiseleitung und Abzweigstromkreis: Dimensionierung und Schutz nach NEC<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/wer-genehmigt-spannungszuschaltung-schaltanlage\/\" target=\"_blank\" rel=\"noopener noreferrer\">Wer die Zuschaltung elektrischer Verteilungen freigibt<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/offene-vs-geschlossene-industrielle-bedienfelder\/\" target=\"_blank\" rel=\"noopener noreferrer\">Offene oder eingehauste Steuerungen: die passende Ausf\u00fchrung<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/was-ist-der-unterschied-zwischen-schalttafeln-und-schaltschranken\/\" target=\"_blank\" rel=\"noopener noreferrer\">Steuerschrank oder Geh\u00e4use: Was sollten Sie kaufen?<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Erfahren Sie, wie Sie die SCCR industrieller Steuerschr\u00e4nke nach UL 508A bestimmen, die Bemessungswerte der Komponenten pr\u00fcfen und das Ergebnis mit dem zu erwartenden Kurzschlussstrom vergleichen.<\/p>","protected":false},"author":17,"featured_media":71220,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[80],"tags":[],"class_list":["post-71174","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Jie Lian\"\/>\n\t<meta name=\"google-site-verification\" content=\"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"E-Abel -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How to Determine Industrial Control Panel SCCR - E-Abel\" \/>\n\t\t<meta property=\"og:description\" content=\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-29T07:51:25+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-03T02:41:28+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How to Determine Industrial Control Panel SCCR - E-Abel\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#blogposting\",\"name\":\"How to Determine Industrial Control Panel SCCR - E-Abel\",\"headline\":\"How to Determine Industrial Control Panel SCCR\",\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/jay\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\",\"width\":1448,\"height\":1086,\"caption\":\"Industrial control panel illustrating SCCR determination under UL 508A\"},\"datePublished\":\"2026-10-29T07:51:25+00:00\",\"dateModified\":\"2026-11-03T02:41:28+00:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#listItem\",\"position\":1,\"name\":\"E-able\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#listItem\",\"name\":\"How to Determine Industrial Control Panel SCCR\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#listItem\",\"name\":\"E-able\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#listItem\",\"position\":3,\"name\":\"How to Determine Industrial Control Panel SCCR\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#organization\",\"name\":\"E-Abel\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/\",\"telephone\":\"+8618860978683\",\"foundingDate\":\"2008-08-28\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"value\":150},\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/043b221a8891a285b2aaa66333022ef.png\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#organizationLogo\",\"width\":2560,\"height\":1301,\"caption\":\"E-Abel logo form\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/jay\\\/#author\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/jay\\\/\",\"name\":\"Jie Lian\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Jie Lian\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#webpage\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/\",\"name\":\"How to Determine Industrial Control Panel SCCR - E-Abel\",\"description\":\"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/jay\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/jay\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#mainImage\",\"width\":1448,\"height\":1086,\"caption\":\"Industrial control panel illustrating SCCR determination under UL 508A\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/industrial-control-panel-sccr\\\/#mainImage\"},\"datePublished\":\"2026-10-29T07:51:25+00:00\",\"dateModified\":\"2026-11-03T02:41:28+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/\",\"name\":\"E-Abel\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>How to Determine Industrial Control Panel SCCR - E-Abel<\/title>\n\n","aioseo_head_json":{"title":"SCCR industrieller Steuerschr\u00e4nke bestimmen - E-Abel","description":"Erfahren Sie, wie Sie die SCCR industrieller Steuerschr\u00e4nke nach UL 508A bestimmen, die Bemessungswerte der Komponenten pr\u00fcfen und das Ergebnis mit dem zu erwartenden Kurzschlussstrom vergleichen.","canonical_url":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"google-site-verification":"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#blogposting","name":"How to Determine Industrial Control Panel SCCR - E-Abel","headline":"How to Determine Industrial Control Panel SCCR","author":{"@id":"https:\/\/www.eabel.com\/de\/author\/jay\/#author"},"publisher":{"@id":"https:\/\/www.eabel.com\/de\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","width":1448,"height":1086,"caption":"Industrial control panel illustrating SCCR determination under UL 508A"},"datePublished":"2026-10-29T07:51:25+00:00","dateModified":"2026-11-03T02:41:28+00:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#webpage"},"isPartOf":{"@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/#listItem","position":1,"name":"E-able","item":"https:\/\/www.eabel.com\/de\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/www.eabel.com\/de\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#listItem","name":"How to Determine Industrial Control Panel SCCR"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/#listItem","name":"E-able"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#listItem","position":3,"name":"How to Determine Industrial Control Panel SCCR","previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/www.eabel.com\/de\/#organization","name":"E-Abel","url":"https:\/\/www.eabel.com\/de\/","telephone":"+8618860978683","foundingDate":"2008-08-28","numberOfEmployees":{"@type":"QuantitativeValue","value":150},"logo":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2022\/05\/043b221a8891a285b2aaa66333022ef.png","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#organizationLogo","width":2560,"height":1301,"caption":"E-Abel logo form"},"image":{"@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.eabel.com\/de\/author\/jay\/#author","url":"https:\/\/www.eabel.com\/de\/author\/jay\/","name":"Jie Lian","image":{"@type":"ImageObject","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/bce0af75a87455b7769d969e8e874d9502e34e10641eb2731332f2f68c04c1cc?s=96&d=mm&r=g","width":96,"height":96,"caption":"Jie Lian"}},{"@type":"WebPage","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#webpage","url":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/","name":"How to Determine Industrial Control Panel SCCR - E-Abel","description":"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/www.eabel.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#breadcrumblist"},"author":{"@id":"https:\/\/www.eabel.com\/de\/author\/jay\/#author"},"creator":{"@id":"https:\/\/www.eabel.com\/de\/author\/jay\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#mainImage","width":1448,"height":1086,"caption":"Industrial control panel illustrating SCCR determination under UL 508A"},"primaryImageOfPage":{"@id":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/#mainImage"},"datePublished":"2026-10-29T07:51:25+00:00","dateModified":"2026-11-03T02:41:28+00:00"},{"@type":"WebSite","@id":"https:\/\/www.eabel.com\/de\/#website","url":"https:\/\/www.eabel.com\/de\/","name":"E-Abel","inLanguage":"de-DE","publisher":{"@id":"https:\/\/www.eabel.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"E-Abel -","og:type":"article","og:title":"How to Determine Industrial Control Panel SCCR - E-Abel","og:description":"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.","og:url":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/","og:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","og:image:secure_url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp","og:image:width":1448,"og:image:height":1086,"article:published_time":"2026-10-29T07:51:25+00:00","article:modified_time":"2026-11-03T02:41:28+00:00","twitter:card":"summary_large_image","twitter:title":"How to Determine Industrial Control Panel SCCR - E-Abel","twitter:description":"Learn how to determine industrial control panel SCCR using UL 508A, verify component ratings, and compare the result with available fault current.","twitter:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/10\/Industrial-control-panel-illustrating-SCCR-determination-under-UL-508A.webp"},"aioseo_meta_data":{"post_id":"71174","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":true,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-11-03 02:43:11","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-10-29 05:22:22","updated":"2026-11-03 02:51:21","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/de\/\" title=\"E-able\">E-able<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/de\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tHow to Determine Industrial Control Panel SCCR\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"E-able","link":"https:\/\/www.eabel.com\/de\/"},{"label":"Blog","link":"https:\/\/www.eabel.com\/de\/category\/blog\/"},{"label":"How to Determine Industrial Control Panel SCCR","link":"https:\/\/www.eabel.com\/de\/industrial-control-panel-sccr\/"}],"_links":{"self":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/posts\/71174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/comments?post=71174"}],"version-history":[{"count":0,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/posts\/71174\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/media\/71220"}],"wp:attachment":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/media?parent=71174"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/categories?post=71174"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/tags?post=71174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}