{"id":36729,"date":"2026-11-19T01:39:44","date_gmt":"2026-11-19T01:39:44","guid":{"rendered":"http:\/\/eabel.com\/?p=36729"},"modified":"2026-11-19T06:56:25","modified_gmt":"2026-11-19T06:56:25","slug":"server-rack-schranke-grosen-tiefe-breite-hohe-erklart","status":"publish","type":"post","link":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/","title":{"rendered":"Serverschrankgr\u00f6\u00dfen: Tiefe, Breite und H\u00f6he"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"36729\" class=\"elementor elementor-36729\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ddeb396 e-flex e-con-boxed e-con e-parent\" data-id=\"ddeb396\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bdca925 elementor-widget elementor-widget-text-editor\" data-id=\"bdca925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">Bei standardm\u00e4\u00dfigen 19-Zoll-Serverschr\u00e4nken wird die Einbauh\u00f6he in U angegeben. Ein g\u00e4ngiges Format f\u00fcr Schr\u00e4nke mit voller Rackh\u00f6he ist 42U; Au\u00dfenbreite und Au\u00dfentiefe unterscheiden sich je nach Modell.<\/p>\n<p class=\"p1 translation-block\">Pr\u00fcfen Sie anhand dieser Abmessungen, ob die Hardware hineinpasst und wie viel Platz im Raum ben\u00f6tigt wird. Wenn Sie noch zwischen einem geschlossenen Schrank und einem offenen Rahmen w\u00e4hlen m\u00fcssen, erl\u00e4utert unser <a href=\"https:\/\/www.eabel.com\/de\/rack-montagegehause\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Leitfaden zu Rackgeh\u00e4usen<\/b><\/a> die Bauformen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1a2b2e7 e-flex e-con-boxed e-con e-child\" data-id=\"1a2b2e7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6698230 elementor-widget elementor-widget-text-editor\" data-id=\"6698230\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Das Wichtigste auf einen Blick<\/h2>\n<ul>\n<li>Betrachten Sie die Einbauma\u00dfe der Ger\u00e4te getrennt von den Au\u00dfenma\u00dfen des Schranks.<\/li>\n<li>Ber\u00fccksichtigen Sie bei der Wahl der U-Kapazit\u00e4t Ger\u00e4te, Zubeh\u00f6r und geplante Erweiterungen; pr\u00fcfen Sie die Gesamth\u00f6he des Schranks gesondert.<\/li>\n<li>Stimmen Sie die Tiefe auf die gesamte Installation ab, einschlie\u00dflich Schienenkompatibilit\u00e4t, frontseitiger Anschl\u00fcsse und r\u00fcckseitigen Kabelraums.<\/li>\n<li>Pr\u00fcfen Sie seitliche Kabelwege, Ausbauwege f\u00fcr Komponenten und den Transportweg, bevor Sie die Schrankgr\u00f6\u00dfe freigeben.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9015788 e-flex e-con-boxed e-con e-parent\" data-id=\"9015788\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9cee2b7 elementor-widget elementor-widget-text-editor\" data-id=\"9cee2b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Serverschrankh\u00f6he: U-Einbauh\u00f6he und Gesamth\u00f6he im Vergleich<\/h2><p class=\"p1\">Die Rackh\u00f6he wird in H\u00f6heneinheiten gemessen, abgek\u00fcrzt U oder RU. Eine H\u00f6heneinheit (1U) entspricht 1,75 Zoll bzw. 44,45 mm. Sie definiert den vertikalen Einbauraum f\u00fcr Ger\u00e4te; das eigentliche Ger\u00e4tegeh\u00e4use kann etwas niedriger sein, um das erforderliche Einbauspiel zu erm\u00f6glichen.<\/p><p class=\"p1\">Die Gesamth\u00f6he umfasst die Schrankkonstruktion und den angegebenen Sockel, die Stellf\u00fc\u00dfe oder Rollen. Als Planungsrichtwert kann ein 42U-Schrank insgesamt etwa 2 m (79 Zoll) hoch sein; pr\u00fcfen Sie die Zeichnung des konkreten Modells. Die Tabelle zeigt ausschlie\u00dflich die Einbauh\u00f6he.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Rackh\u00f6he<\/th><th>Einbauh\u00f6he (Zoll)<\/th><th>Einbauh\u00f6he (mm)<\/th><\/tr><\/thead><tbody><tr><td>6HE<\/td><td>10.5<\/td><td>266.7<\/td><\/tr><tr><td>12HE<\/td><td>21.0<\/td><td>533.4<\/td><\/tr><tr><td>18U<\/td><td>31.5<\/td><td>800.1<\/td><\/tr><tr><td>24U<\/td><td>42.0<\/td><td>1066.8<\/td><\/tr><tr><td>42U<\/td><td>73.5<\/td><td>1866.9<\/td><\/tr><tr><td>48U<\/td><td>84.0<\/td><td>2133.6<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1 translation-block\">Addieren Sie f\u00fcr die Kapazit\u00e4tsplanung die U-Positionen, die Server, Switches, Patchpanels, eine gegebenenfalls vorhandene unterbrechungsfreie Stromversorgung (USV) und Zubeh\u00f6r belegen. Rechnen Sie bei Ger\u00e4ten auf Fachb\u00f6den die gesamte belegte H\u00f6he ein; die <a href=\"https:\/\/www.eabel.com\/de\/belastbarkeit-des-serverracks\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Tragf\u00e4higkeit des Racks<\/b><\/a> ist ein gesonderter Grenzwert.<\/p><p class=\"p1\">Planen Sie Platz f\u00fcr vorgesehene Erweiterungen ein, einschlie\u00dflich der zugeh\u00f6rigen Kabelf\u00fchrungen und Tragelemente. Wenn die geplanten Erweiterungen feststehen, verwenden Sie deren tats\u00e4chlichen U-Bedarf statt eines pauschalen prozentualen Zuschlags.<\/p><p class=\"p1 translation-block\">Betrachten Sie Erweiterungsreserven getrennt von den Bel\u00fcftungsanforderungen. Halten Sie die Abstandsvorgaben in der Installationsanleitung jedes Ger\u00e4ts ein. Bei Luftf\u00fchrung von vorn nach hinten <a href=\"https:\/\/www.energystar.gov\/products\/data_center_equipment\/16-more-ways-cut-energy-waste-data-center\/manage-airflow-cooling-efficiency\" target=\"_blank\" rel=\"noopener noreferrer\"><b>verschlie\u00dfen Blindplatten ungenutzte Rackpl\u00e4tze<\/b><\/a> und tragen so dazu bei, die Zuluft durch die Ger\u00e4te zu leiten.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-67821\" title=\"Serverschr\u00e4nke mit ge\u00f6ffneten Glast\u00fcren\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2026\/03\/Server-rack-cabinets-with-open-glass-doors.webp\" alt=\"Serverschr\u00e4nke mit ge\u00f6ffneten Glast\u00fcren\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/03\/Server-rack-cabinets-with-open-glass-doors.webp 1280w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/03\/Server-rack-cabinets-with-open-glass-doors-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/03\/Server-rack-cabinets-with-open-glass-doors-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>Serverschrankbreite: 19-Zoll-Einbaubreite und Schrankbreite im Vergleich<\/h2><p class=\"p1 translation-block\">Die Bezeichnung 19 Zoll bezieht sich auf die Nennbreite der Ger\u00e4tefrontplatte einschlie\u00dflich der Befestigungslaschen: 482,6 mm. Die <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/1283\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Norm IEC 60297-3-100<\/b><\/a> behandelt diese mechanische Baureihe. Die Au\u00dfenbreite des Schranks, die lichte Weite zwischen den Montageprofilen und der Abstand der Befestigungsl\u00f6cher sind eigenst\u00e4ndige Ma\u00dfe.<\/p><p class=\"p1\">Die Au\u00dfenbreite bestimmt die Stellfl\u00e4che und den seitlichen Platz f\u00fcr Kabel und Stromverteilerleisten (PDUs), die Steckdosen bereitstellen. G\u00e4ngige Varianten sind 600 mm (23,62 Zoll), 750 mm (29,53 Zoll) und 800 mm (31,50 Zoll).<\/p><p class=\"p1\">Mit einem 600 mm breiten Schrank bleibt die Schrankreihe kompakt. W\u00e4hlen Sie 750 oder 800 mm, wenn eine hohe Patchkabeldichte, vertikale Kabelf\u00fchrungen oder PDUs mehr seitlichen Platz ben\u00f6tigen. Pr\u00fcfen Sie anschlie\u00dfend, ob das Modell an diesen Stellen nutzbare Kan\u00e4le bietet.<\/p><p class=\"p1 translation-block\">Eine vertikale 0U-PDU wird neben oder hinter den Ger\u00e4ten montiert und belegt keine frontseitigen U-Positionen. Pr\u00fcfen Sie, ob ihre gesamte L\u00e4nge und ihre Befestigungspunkte zum Schrank passen. Kontrollieren Sie anschlie\u00dfend bei eingebautem Ger\u00e4tegeh\u00e4use und montierten <a href=\"https:\/\/www.eabel.com\/de\/serverschrank-kabelmanagement\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Kabelf\u00fchrungen<\/b><\/a> die Freir\u00e4ume f\u00fcr PDU-Geh\u00e4use, Stecker und Kabel.<\/p><p class=\"p1\">Vergleichen Sie bei einer bestehenden Schrankreihe die tats\u00e4chlichen Ma\u00dfe statt gerundeter Angaben wie \u201e24 Zoll breit\u201c. \u00c4hnliche Angaben in Millimetern und Zoll k\u00f6nnen unterschiedliche Stellfl\u00e4chen bezeichnen.<\/p><h2>Serverschranktiefe: Schrankma\u00dfe, passende Schienen und Freir\u00e4ume<\/h2><p class=\"p1\">Schranktiefe: Verwenden Sie das Gesamtma\u00df von vorn nach hinten im montierten Zustand aus der Zeichnung. Tiefenangaben im Katalog k\u00f6nnen von den tats\u00e4chlichen Fertigma\u00dfen abweichen. Pr\u00fcfen Sie deshalb, ob T\u00fcren, Griffe und andere \u00dcberst\u00e4nde darin enthalten sind.<\/p><p class=\"p1\">Schienenmontageabstand: Vergleichen Sie den Abstand zwischen den vorderen und hinteren Montagefl\u00e4chen mit dem zul\u00e4ssigen Bereich des Schienensatzes f\u00fcr das eingebaute System. Ger\u00e4tegeh\u00e4use oder Schienen k\u00f6nnen \u00fcber die hinteren Montageprofile hinausragen.<\/p><p class=\"p1\">Einbaufreir\u00e4ume: Planen Sie bei geschlossenen T\u00fcren Platz f\u00fcr Frontblenden, Patchkabel, r\u00fcckseitige Stecker, Kabelb\u00f6gen und gegebenenfalls einen Kabelf\u00fchrungsarm (CMA) ein.<\/p><p class=\"p1\">Wenn ein Datenblatt eine \u201eNutztiefe\u201c angibt, kl\u00e4ren Sie, ob damit der maximale Schienenabstand, die Auflagetiefe f\u00fcr Fachb\u00f6den oder der freie Ger\u00e4teraum gemeint ist. Leiten Sie diese nicht durch Abzug eines pauschalen Werts von der Au\u00dfentiefe ab.<\/p><h3>Montagebereiche der Schienen verschiedener Ger\u00e4te aufeinander abstimmen<\/h3><p class=\"p1\">Bei Ger\u00e4ten, die dieselben vorderen und hinteren Montageprofile nutzen, m\u00fcssen sich die zul\u00e4ssigen Montagebereiche \u00fcberschneiden, und der Schrank muss diese gemeinsame Einstellung erm\u00f6glichen.<\/p><p class=\"p1\">Pr\u00fcfen Sie die Herstellermatrix f\u00fcr den konkreten Server, den Schienensatz und die Befestigungsl\u00f6cher: quadratisch, rund ohne Gewinde oder mit Gewinde. Die Bezeichnung 19 Zoll allein gew\u00e4hrleistet nicht, dass werkzeuglos montierbare Schienen befestigt werden k\u00f6nnen. Beachten Sie alle Fu\u00dfnoten zur jeweiligen Konfiguration.<\/p><p class=\"p1\">Ein hypothetisches Beispiel: Schiene A unterst\u00fctzt einen Montageabstand von 650 bis 800 mm, Schiene B einen von 750 bis 900 mm. Der gemeinsame Bereich reicht von 750 bis 800 mm. Eine Einstellung in diesem Bereich erf\u00fcllt diese Abstandspr\u00fcfung, sofern der Schrank sie erm\u00f6glicht.<\/p><p class=\"p1\">Wenn sich die Bereiche nicht \u00fcberschneiden, pr\u00fcfen Sie eine vom Hersteller freigegebene alternative Schiene oder Tragkonstruktion oder bringen Sie die Ger\u00e4te getrennt unter. Ein tieferes Geh\u00e4use allein l\u00f6st widerspr\u00fcchliche Schienenanforderungen nicht.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-52876\" title=\"Serverschrank\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/05\/Server-Rack-Cabinet-scaled.webp\" alt=\"Serverschrank\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/05\/Server-Rack-Cabinet-scaled.webp 2560w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/05\/Server-Rack-Cabinet-500x333.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/05\/Server-Rack-Cabinet-1536x1024.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/05\/Server-Rack-Cabinet-2048x1365.webp 2048w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/05\/Server-Rack-Cabinet-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>G\u00e4ngige Schranktiefen vergleichen<\/h3><p class=\"p1\">Nutzen Sie diese typischen Au\u00dfentiefen, um Schr\u00e4nke in die engere Auswahl zu nehmen. Pr\u00fcfen Sie anhand der Ger\u00e4te- und Schrankzeichnungen, ob alles passt.<\/p><div style=\"overflow-x: auto; max-width: 100%;\"><table><thead><tr><th>Au\u00dfentiefe<\/th><th>Ca. Zoll<\/th><th>Auswahlhinweise<\/th><\/tr><\/thead><tbody><tr><td>600 mm<\/td><td>23.62<\/td><td>Kompakte Netzwerkger\u00e4te; frontseitige Patchkabel und r\u00fcckseitige Stecker pr\u00fcfen<\/td><\/tr><tr><td>800 mm<\/td><td>31.50<\/td><td>Netzwerkger\u00e4te und Systeme mit geringer Bautiefe; Tragelemente und Kabelraum pr\u00fcfen<\/td><\/tr><tr><td>1000 mm<\/td><td>39.37<\/td><td>F\u00fcr Server und Speicher geeignet, sofern die gesamte Installation hineinpasst<\/td><\/tr><tr><td>1070 mm<\/td><td>42.13<\/td><td>Zwischengr\u00f6\u00dfe in einigen Baureihen; Schienengrenzen und Freir\u00e4ume an den T\u00fcren pr\u00fcfen<\/td><\/tr><tr><td>1200 mm<\/td><td>47.24<\/td><td>Je nach Anordnung zus\u00e4tzlicher Platz f\u00fcr tiefere Ger\u00e4tegeh\u00e4use, CMAs und PDUs<\/td><\/tr><\/tbody><\/table><\/div><p class=\"p1\">W\u00e4hlen Sie 1000 mm, wenn die dokumentierte Installation hineinpasst. Pr\u00fcfen Sie 1200 mm, wenn die vorhandene Hardware oder geplante Ersatzger\u00e4te mehr Tiefe ben\u00f6tigen. Stellen Sie sicher, dass die gr\u00f6\u00dfere Stellfl\u00e4che in den Raum passt.<\/p><h2>Die passende Rackgr\u00f6\u00dfe ausw\u00e4hlen und \u00fcberpr\u00fcfen<\/h2><h3>Einbauformat w\u00e4hlen<\/h3><p class=\"p1\">Ein Wandgeh\u00e4use und ein Standschrank mit derselben U-Kapazit\u00e4t k\u00f6nnen sehr unterschiedliche Tiefen- und Lastgrenzen haben. Pr\u00fcfen Sie bei Wandmontage die Tragf\u00e4higkeit der Wand, das Befestigungsmaterial und den r\u00fcckseitigen Zugang einschlie\u00dflich des Freiraums f\u00fcr Scharniere, sofern vorhanden.<\/p><p class=\"p1\">Pr\u00fcfen Sie f\u00fcr tiefe oder schwere Serverinstallationen einen Standschrank mit vier Montageprofilen. Stellen Sie sicher, dass der Schienensatz diese Profilanordnung unterst\u00fctzt; Racks mit zwei Montageprofilen erfordern Ger\u00e4te oder Tragelemente, die f\u00fcr diese Montageart freigegeben sind.<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-51511\" title=\"Serverschrankschl\u00f6sser\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/04\/server-rack-cabinets-locks.webp\" alt=\"Serverschrankschl\u00f6sser\" width=\"500\" height=\"386\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/04\/server-rack-cabinets-locks.webp 1536w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/04\/server-rack-cabinets-locks-500x386.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/04\/server-rack-cabinets-locks-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h3>Ein Beispiel zur Rackdimensionierung durchrechnen<\/h3><p class=\"p1\">Betrachten wir einen hypothetischen kleinen Serverraum. Acht 2U-Server belegen 16U. Switches und Patchpanels belegen 4U, eine USV belegt 3U, und eine Fachbodeneinheit einschlie\u00dflich ihrer Ger\u00e4te belegt 2U. Der aktuelle Gesamtbedarf betr\u00e4gt 25U.<\/p><p class=\"p1\">Die freigegebene Erweiterung f\u00fcgt weitere 8U hinzu:<\/p><p class=\"p1\">25U vorhandene Ger\u00e4te + 8U geplante Erg\u00e4nzungen = 33U erforderliche Kapazit\u00e4t.<\/p><p class=\"p1\">Ein 42U-Schrank kommt daf\u00fcr infrage; auch andere verf\u00fcgbare H\u00f6hen k\u00f6nnten 33U aufnehmen.<\/p><p class=\"p1\">Angenommen, die vorgesehene Anordnung erfordert zwei vertikale Kabelwege und zwei PDUs. Pr\u00fcfen Sie zun\u00e4chst ein 800 mm breites Modell und best\u00e4tigen Sie anschlie\u00dfend, dass seine Innenaufteilung diese Bauteile aufnehmen kann.<\/p><p class=\"p1\">Nehmen wir f\u00fcr dieses Beispiel an, dass die ausgew\u00e4hlten Server 750 mm tief sind. Die Zeichnung des vorgesehenen 1000-mm-Schranks zeigt eine Kollision mit dem gew\u00e4hlten CMA, w\u00e4hrend die 1200-mm-Ausf\u00fchrung den n\u00f6tigen Freiraum bietet und die erforderlichen Schienenpositionen unterst\u00fctzt.<\/p><p class=\"p1\">Unter diesen Annahmen kommt eine Konfiguration mit 42U \u00d7 800 mm Breite \u00d7 1200 mm Tiefe infrage.<\/p><p class=\"p1 translation-block\">Bei 800 mm Breite vergr\u00f6\u00dfert eine Erh\u00f6hung der Tiefe von 1000 auf 1200 mm die Stellfl\u00e4che des Schranks von 0,80 auf 0,96 m<sup>2<\/sup>, also um 20%. Diese Werte schlie\u00dfen G\u00e4nge, offene T\u00fcren und Wartungsfl\u00e4chen aus; beurteilen Sie die gesamte Aufstellung mit den erforderlichen Arbeitsfl\u00e4chen gesondert.<\/p><p class=\"p1 translation-block\">Die <a href=\"https:\/\/www.eabel.com\/de\/schranke-und-behalter\/server-rack-schranke-2\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Serverschr\u00e4nke<\/b><\/a> von E-ABEL bieten verschiedene Optionen f\u00fcr Abmessungen, Montageschienen und Kabelf\u00fchrung. Besprechen Sie diese M\u00f6glichkeiten anhand Ihrer Ger\u00e4teliste und Ihres Aufstellplans, bevor Sie eine Konfiguration best\u00e4tigen.<\/p><p class=\"p1 translation-block\">Halten Sie f\u00fcr k\u00fcnftige, noch nicht ausgew\u00e4hlte Erg\u00e4nzungen neben der U-Reserve auch einen zul\u00e4ssigen Tiefen- und Gewichtsbereich fest. Ber\u00fccksichtigen Sie bei der Dimensionierung der Kabelwege die geplante Anzahl an Patchkabeln und halten Sie dabei <a href=\"https:\/\/www.energy.gov\/sites\/default\/files\/2024-07\/best-practice-guide-data-center-design.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Luftein- und Luftausl\u00e4sse frei<\/b><\/a>.<\/p><h3>Anlieferung und Wartungszugang vor der Bestellung pr\u00fcfen<\/h3><p class=\"p1\">F\u00fchren Sie die folgenden Pr\u00fcfungen der r\u00e4umlichen Gegebenheiten durch, bevor Sie die Bestellung freigeben. Verwenden Sie die Zeichnung des montierten Schranks, die Verpackungsma\u00dfe und die Wartungsanleitungen der Ger\u00e4te jeweils f\u00fcr ihren vorgesehenen Zweck.<\/p><ul><li>Gesamtabmessungen: Pr\u00fcfen Sie die H\u00f6he im montierten Zustand einschlie\u00dflich des angegebenen Sockels, der Stellf\u00fc\u00dfe oder Rollen und der Aufbauten. Ber\u00fccksichtigen Sie Kabeltrassen oberhalb des Schranks, Hindernisse an der Decke und gegebenenfalls erforderliche Abst\u00e4nde unter Brandschutzeinrichtungen. Erfassen Sie die Verpackungsma\u00dfe gesondert.<\/li><li>Transportweg: Messen Sie lichte T\u00fcr\u00f6ffnungen, Flurbiegungen, Aufz\u00fcge und den letzten Abschnitt bis zum Aufstellort. Stimmen Sie besondere Auspack- oder Montageverfahren mit dem Lieferanten ab.<\/li><li>Arbeitsraum: Pr\u00fcfen Sie den T\u00fcrschwenkbereich, den vollst\u00e4ndigen Schienenauszug und den Zugang zu Kabeleinf\u00fchrungen oben oder unten. Ber\u00fccksichtigen Sie \u00dcberst\u00e4nde erforderlicher Kippsicherungen und befolgen Sie die Anweisungen f\u00fcr Rack und Ger\u00e4te zur Stabilisierung oder Verankerung.<\/li><li>Ausbau von Komponenten: Pr\u00fcfen Sie in der Wartungsanleitung Ihres Ger\u00e4ts die Ausbauwege f\u00fcr Netzteile und Controller und halten Sie diese Wege von PDUs und Kabeln frei.<\/li><li>Gewicht im best\u00fcckten Zustand: Rechnen Sie Schrank, Ger\u00e4te und Zubeh\u00f6r ein. Pr\u00fcfen Sie die statische Tragf\u00e4higkeit f\u00fcr die angegebene Aufstellkonfiguration und die Bodentragf\u00e4higkeit an den Stellf\u00fc\u00dfen oder Rollen. Pr\u00fcfen Sie die zul\u00e4ssige Last beim Verfahren im best\u00fcckten Zustand, wenn Sie den Schrank mit eingebauten Ger\u00e4ten bewegen.<\/li><li>Abschlie\u00dfende Dokumentation: Fordern Sie die Ma\u00dfzeichnung mit eindeutig gekennzeichneter H\u00f6he, Breite und Tiefe sowie die Schieneneinstellungen, den Lochtyp und die Zubeh\u00f6rpositionen f\u00fcr die gelieferte Konfiguration an.<\/li><\/ul><p class=\"p1 translation-block\">Die Abmessungen sind ein Teil der Freigabe f\u00fcr den Einsatz. Stromversorgung, K\u00fchlung, Sicherheit und Standortanforderungen geh\u00f6ren zur umfassenderen <a href=\"https:\/\/www.eabel.com\/de\/auswahl-des-richtigen-rack-schranks-fur-ihr-rechenzentrum\/\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Pr\u00fcfung zur Auswahl eines Rechenzentrumsracks<\/b><\/a>, bevor Sie entscheiden, wie weit Sie den Schrank best\u00fccken.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-65919\" title=\"Serverracks veranschaulichen den Unterschied zwischen einem Serverschrank und einem Netzwerkschrank\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Server-racks-illustrate-the-difference-between-a-server-cabinet-and-a-network-cabinet.webp\" alt=\"Serverracks veranschaulichen den Unterschied zwischen einem Serverschrank und einem Netzwerkschrank\" width=\"500\" height=\"352\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Server-racks-illustrate-the-difference-between-a-server-cabinet-and-a-network-cabinet.webp 540w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Server-racks-illustrate-the-difference-between-a-server-cabinet-and-a-network-cabinet-500x352.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/01\/Server-racks-illustrate-the-difference-between-a-server-cabinet-and-a-network-cabinet-18x12.webp 18w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><h2>H\u00e4ufige Fragen zu Serverschrank-Abmessungen<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55f059c elementor-widget elementor-widget-n-accordion\" data-id=\"55f059c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Akkordeon. Links mit der Eingabe- oder Leertaste \u00f6ffnen, mit Escape schlie\u00dfen und mit den Pfeiltasten navigieren\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9010\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-9010\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Welche Abmessungen hat ein 42U-Serverschrank? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9010\" class=\"elementor-element elementor-element-ce6f3e3 e-flex e-con-boxed e-con e-child\" data-id=\"ce6f3e3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-047ff5a elementor-widget elementor-widget-text-editor\" data-id=\"047ff5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>42U bieten 73,5 Zoll (1866,9 mm) Einbauh\u00f6he f\u00fcr Ger\u00e4te. Die Gesamth\u00f6he des Schranks ist gr\u00f6\u00dfer und variiert je nach Modell. G\u00e4ngige Au\u00dfenbreiten sind 600, 750 und 800 mm; typische Serverschranktiefen sind beispielsweise 1000, 1070 und 1200 mm.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9011\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-9011\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Sollte ich einen 1000 mm tiefen oder einen 1200 mm tiefen Serverschrank w\u00e4hlen? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9011\" class=\"elementor-element elementor-element-4bd8533 e-flex e-con-boxed e-con e-child\" data-id=\"4bd8533\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dc11166 elementor-widget elementor-widget-text-editor\" data-id=\"dc11166\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>W\u00e4hlen Sie 1000 mm, wenn die gesamte Installation hineinpasst, einschlie\u00dflich Schienen, Steckern, Kabelb\u00f6gen und geschlossenen T\u00fcren. Pr\u00fcfen Sie 1200 mm, wenn tiefere Ger\u00e4te oder Kabelf\u00fchrungsarme zus\u00e4tzlichen Platz ben\u00f6tigen. Stellen Sie sicher, dass der gr\u00f6\u00dfere Schrank ausreichend Raum f\u00fcr die Wartung l\u00e4sst.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9012\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-9012\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Reicht ein 600 mm breites Rack f\u00fcr Server und zwei vertikale PDUs aus? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9012\" class=\"elementor-element elementor-element-ea13b64 e-flex e-con-boxed e-con e-child\" data-id=\"ea13b64\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-13b6a2b elementor-widget elementor-widget-text-editor\" data-id=\"13b6a2b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das ist m\u00f6glich, sofern die Zubeh\u00f6rkan\u00e4le des Schranks beide PDUs samt Steckern und Kabelwegen aufnehmen. Stellen Sie sicher, dass sie den Ausbau der Ger\u00e4te nicht behindern. Ein 750 oder 800 mm breiter Schrank bietet mehr seitlichen Platz, wenn seine Innenkonstruktion dies erm\u00f6glicht.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9013\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-9013\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Passt jeder 19-Zoll-Server in einen 19-Zoll-Serverschrank? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9013\" class=\"elementor-element elementor-element-5358cc5 e-flex e-con-boxed e-con e-child\" data-id=\"5358cc5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9135749 elementor-widget elementor-widget-text-editor\" data-id=\"9135749\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Die Bezeichnung 19 Zoll beschreibt das Einbauformat. Sie m\u00fcssen au\u00dferdem Ger\u00e4teh\u00f6he, Geh\u00e4usetiefe, Verstellbereich der Schienen, Art der Befestigungsl\u00f6cher und Lastgrenzen aufeinander abstimmen. Best\u00e4tigen Sie vor der Bestellung die Kompatibilit\u00e4t des konkreten Servers und Schienensatzes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9014\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-9014\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wie viel U-Reserve sollte ich f\u00fcr k\u00fcnftige Erweiterungen vorsehen? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9014\" class=\"elementor-element elementor-element-0e14a40 e-flex e-con-boxed e-con e-child\" data-id=\"0e14a40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-10ffe9b elementor-widget elementor-widget-text-editor\" data-id=\"10ffe9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Reservieren Sie gen\u00fcgend U-Positionen f\u00fcr geplante Ger\u00e4te und deren Zubeh\u00f6r, einschlie\u00dflich Fachb\u00f6den und horizontaler Kabelf\u00fchrungen. Verwenden Sie die voraussichtliche Erweiterungsliste statt eines festen Prozentsatzes. Pr\u00fcfen Sie k\u00fcnftige Anforderungen an Tiefe, Gewicht, Stromversorgung und K\u00fchlung gesondert.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9015\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-9015\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Welche Angaben sollte ich f\u00fcr ein Angebot \u00fcber einen Serverschrank bereitstellen? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9015\" class=\"elementor-element elementor-element-f45e4d9 e-flex e-con-boxed e-con e-child\" data-id=\"f45e4d9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7e22371 elementor-widget elementor-widget-text-editor\" data-id=\"7e22371\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Senden Sie Ihre Ger\u00e4teliste, Geh\u00e4usetiefen, Angaben zu den Schienens\u00e4tzen, Ger\u00e4tegewichte und geplante Erweiterungen. Geben Sie die gew\u00fcnschte U-Kapazit\u00e4t, Schrankbreite und -tiefe, PDU-Positionen und r\u00e4umliche Einschr\u00e4nkungen wie T\u00fcr\u00f6ffnungen oder Deckenh\u00f6he an. Fordern Sie vor der Freigabe eine Konfigurationszeichnung an.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d864754 elementor-widget elementor-widget-text-editor\" data-id=\"d864754\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fazit<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-50008\" title=\"Serverschrank f\u00fcr ein Rechenzentrum\" src=\"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/03\/server-rack-cabinet-for-datacenter-e1741670975252.webp\" alt=\"Serverschrank f\u00fcr ein Rechenzentrum\" width=\"500\" height=\"375\" srcset=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/03\/server-rack-cabinet-for-datacenter-e1741670975252.webp 1290w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/03\/server-rack-cabinet-for-datacenter-e1741670975252-500x375.webp 500w, https:\/\/www.eabel.com\/wp-content\/uploads\/2025\/03\/server-rack-cabinet-for-datacenter-e1741670975252-16x12.webp 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p><p class=\"p1\">W\u00e4hlen Sie den Serverschrank entsprechend den Ger\u00e4ten aus, die Sie w\u00e4hrend seiner geplanten Nutzungsdauer installieren, anschlie\u00dfen und warten werden. Der Abgleich der gesamten Anordnung mit der Schrankzeichnung hilft Ihnen, eine passende Gr\u00f6\u00dfe sicher auszuw\u00e4hlen. Die Pr\u00fcfungen vor Ort best\u00e4tigen, dass der Schrank angeliefert und bestimmungsgem\u00e4\u00df genutzt werden kann.<\/p><p class=\"p1 translation-block\">F\u00fcr eine Neuinstallation oder den Austausch bzw. die Modernisierung von Ger\u00e4ten <a href=\"https:\/\/www.eabel.com\/de\/kontakt\/\" target=\"_blank\" rel=\"noopener\"><strong>kontaktieren Sie E-ABEL<\/strong><\/a> mit Ihrer Ger\u00e4teliste und Ihrem Raumplan. Unser Team kann vor Ihrer Bestellung Schrankabmessungen, Schienenpositionen und die Anordnung des Zubeh\u00f6rs mit Ihnen besprechen. Wenn Sie die Anordnung jetzt pr\u00fcfen, lassen sich Konflikte erkennen, solange \u00c4nderungen noch einfach m\u00f6glich sind.<\/p><h2 class=\"translation-block\"><b>Weiterf\u00fchrende Artikel<\/b><\/h2><p><a href=\"https:\/\/www.eabel.com\/de\/was-ist-ein-19-zoll-rack\/\" target=\"_blank\" rel=\"noopener noreferrer\">Was ist ein 19-Zoll-Rack? Leitfaden f\u00fcr IT und AV<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/was-sind-die-standards-fur-rackschranke\/\" target=\"_blank\" rel=\"noopener noreferrer\">Welche Normen gelten f\u00fcr Rackschr\u00e4nke?<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/server-racks-mit-offenem-rahmen-vs-geschlossene-server-racks\/\" target=\"_blank\" rel=\"noopener noreferrer\">Offene und geschlossene Serverracks: Die wichtigsten Unterschiede erkl\u00e4rt<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/was-sind-serverrack-zubehorteile\/\" target=\"_blank\" rel=\"noopener noreferrer\">Was ist Serverrack-Zubeh\u00f6r? Arten, Funktionen und Vorteile<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/server-rack-kuhlung\/\" target=\"_blank\" rel=\"noopener noreferrer\">Umfassender Leitfaden zur K\u00fchlung von Serverracks<\/a><\/p><p><a href=\"https:\/\/www.eabel.com\/de\/so-planen-sie-die-installation-eines-server-rack-schranks\/\" target=\"_blank\" rel=\"noopener noreferrer\">Die Installation eines Serverschranks planen<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Lernen Sie die Gr\u00f6\u00dfen von Serverschr\u00e4nken kennen: H\u00f6he in H\u00f6heneinheiten (U), 19-Zoll-Einbaubreite und Schranktiefe sowie die Pr\u00fcfungen, die sicherstellen, dass Ihre Ger\u00e4te in den Schrank passen.<\/p>","protected":false},"author":16,"featured_media":71641,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[80],"tags":[],"class_list":["post-36729","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Understand server rack cabinet sizes, including U height, 19-inch mounting width, cabinet depth, and the checks that ensure your equipment fits.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Linsey Zhou\"\/>\n\t<meta name=\"google-site-verification\" content=\"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"E-Abel -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Server Rack Cabinet Sizes: Depth, Width &amp; Height - E-Abel\" \/>\n\t\t<meta property=\"og:description\" content=\"Understand server rack cabinet sizes, including U height, 19-inch mounting width, cabinet depth, and the checks that ensure your equipment fits.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-19T01:39:44+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-19T06:56:25+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Server Rack Cabinet Sizes: Depth, Width &amp; Height - E-Abel\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Understand server rack cabinet sizes, including U height, 19-inch mounting width, cabinet depth, and the checks that ensure your equipment fits.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#blogposting\",\"name\":\"Server Rack Cabinet Sizes: Depth, Width & Height - E-Abel\",\"headline\":\"Server Rack Cabinet Sizes: Depth, Width &amp; Height\",\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/linsey-zhou\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Server-rack-cabinet-depth-width-and-height.webp\",\"width\":1448,\"height\":1086,\"caption\":\"Server rack cabinet depth width and height\"},\"datePublished\":\"2026-11-19T01:39:44+00:00\",\"dateModified\":\"2026-11-19T06:56:25+00:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#listItem\",\"position\":1,\"name\":\"E-able\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#listItem\",\"name\":\"Server Rack Cabinet Sizes: Depth, Width &amp; Height\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#listItem\",\"name\":\"E-able\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#listItem\",\"position\":3,\"name\":\"Server Rack Cabinet Sizes: Depth, Width &amp; Height\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#organization\",\"name\":\"E-Abel\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/\",\"telephone\":\"+8618860978683\",\"foundingDate\":\"2008-08-28\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"value\":150},\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/043b221a8891a285b2aaa66333022ef.png\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#organizationLogo\",\"width\":2560,\"height\":1301,\"caption\":\"E-Abel logo form\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/linsey-zhou\\\/#author\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/linsey-zhou\\\/\",\"name\":\"Linsey Zhou\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#authorImage\",\"url\":\"http:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/cropped-Linsey-scaled-e1739864096326-96x96.webp\",\"width\":96,\"height\":96,\"caption\":\"Linsey Zhou\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#webpage\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/\",\"name\":\"Server Rack Cabinet Sizes: Depth, Width & Height - E-Abel\",\"description\":\"Understand server rack cabinet sizes, including U height, 19-inch mounting width, cabinet depth, and the checks that ensure your equipment fits.\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/linsey-zhou\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/author\\\/linsey-zhou\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Server-rack-cabinet-depth-width-and-height.webp\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#mainImage\",\"width\":1448,\"height\":1086,\"caption\":\"Server rack cabinet depth width and height\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/server-rack-cabinets-sizes-depth-width-height-explained\\\/#mainImage\"},\"datePublished\":\"2026-11-19T01:39:44+00:00\",\"dateModified\":\"2026-11-19T06:56:25+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/\",\"name\":\"E-Abel\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eabel.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Server Rack Cabinet Sizes: Depth, Width &amp; Height - E-Abel<\/title>\n\n","aioseo_head_json":{"title":"Serverschrank-Abmessungen: Tiefe, Breite und H\u00f6he - E-Abel","description":"Lernen Sie die Gr\u00f6\u00dfen von Serverschr\u00e4nken kennen: H\u00f6he in H\u00f6heneinheiten (U), 19-Zoll-Einbaubreite und Schranktiefe sowie die Pr\u00fcfungen, die sicherstellen, dass Ihre Ger\u00e4te in den Schrank passen.","canonical_url":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"google-site-verification":"1wYrj2wMR08VkFVPekPDygcLhkejwyc4Tx5iltGVzdk","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#blogposting","name":"Server Rack Cabinet Sizes: Depth, Width & Height - E-Abel","headline":"Server Rack Cabinet Sizes: Depth, Width &amp; Height","author":{"@id":"https:\/\/www.eabel.com\/de\/author\/linsey-zhou\/#author"},"publisher":{"@id":"https:\/\/www.eabel.com\/de\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp","width":1448,"height":1086,"caption":"Server rack cabinet depth width and height"},"datePublished":"2026-11-19T01:39:44+00:00","dateModified":"2026-11-19T06:56:25+00:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#webpage"},"isPartOf":{"@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/#listItem","position":1,"name":"E-able","item":"https:\/\/www.eabel.com\/de\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/www.eabel.com\/de\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#listItem","name":"Server Rack Cabinet Sizes: Depth, Width &amp; Height"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/#listItem","name":"E-able"}},{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#listItem","position":3,"name":"Server Rack Cabinet Sizes: Depth, Width &amp; Height","previousItem":{"@type":"ListItem","@id":"https:\/\/www.eabel.com\/de\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/www.eabel.com\/de\/#organization","name":"E-Abel","url":"https:\/\/www.eabel.com\/de\/","telephone":"+8618860978683","foundingDate":"2008-08-28","numberOfEmployees":{"@type":"QuantitativeValue","value":150},"logo":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2022\/05\/043b221a8891a285b2aaa66333022ef.png","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#organizationLogo","width":2560,"height":1301,"caption":"E-Abel logo form"},"image":{"@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.eabel.com\/de\/author\/linsey-zhou\/#author","url":"https:\/\/www.eabel.com\/de\/author\/linsey-zhou\/","name":"Linsey Zhou","image":{"@type":"ImageObject","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#authorImage","url":"http:\/\/www.eabel.com\/wp-content\/uploads\/2025\/02\/cropped-Linsey-scaled-e1739864096326-96x96.webp","width":96,"height":96,"caption":"Linsey Zhou"}},{"@type":"WebPage","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#webpage","url":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/","name":"Server Rack Cabinet Sizes: Depth, Width & Height - E-Abel","description":"Understand server rack cabinet sizes, including U height, 19-inch mounting width, cabinet depth, and the checks that ensure your equipment fits.","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/www.eabel.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#breadcrumblist"},"author":{"@id":"https:\/\/www.eabel.com\/de\/author\/linsey-zhou\/#author"},"creator":{"@id":"https:\/\/www.eabel.com\/de\/author\/linsey-zhou\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp","@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#mainImage","width":1448,"height":1086,"caption":"Server rack cabinet depth width and height"},"primaryImageOfPage":{"@id":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/#mainImage"},"datePublished":"2026-11-19T01:39:44+00:00","dateModified":"2026-11-19T06:56:25+00:00"},{"@type":"WebSite","@id":"https:\/\/www.eabel.com\/de\/#website","url":"https:\/\/www.eabel.com\/de\/","name":"E-Abel","inLanguage":"de-DE","publisher":{"@id":"https:\/\/www.eabel.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"E-Abel -","og:type":"article","og:title":"Server Rack Cabinet Sizes: Depth, Width &amp; Height - E-Abel","og:description":"Understand server rack cabinet sizes, including U height, 19-inch mounting width, cabinet depth, and the checks that ensure your equipment fits.","og:url":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/","og:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp","og:image:secure_url":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp","og:image:width":1448,"og:image:height":1086,"article:published_time":"2026-11-19T01:39:44+00:00","article:modified_time":"2026-11-19T06:56:25+00:00","twitter:card":"summary_large_image","twitter:title":"Server Rack Cabinet Sizes: Depth, Width &amp; Height - E-Abel","twitter:description":"Understand server rack cabinet sizes, including U height, 19-inch mounting width, cabinet depth, and the checks that ensure your equipment fits.","twitter:image":"https:\/\/www.eabel.com\/wp-content\/uploads\/2026\/11\/Server-rack-cabinet-depth-width-and-height.webp"},"aioseo_meta_data":{"post_id":"36729","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-11-20 02:43:31","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":"{\"title\":{\"suggestions\":[],\"usage\":0},\"description\":{\"suggestions\":[],\"usage\":0}}","ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2024-06-07 07:56:31","updated":"2026-11-20 02:44:55","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/de\/\" title=\"E-able\">E-able<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.eabel.com\/de\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tServer Rack Cabinet Sizes: Depth, Width &amp; Height\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"E-able","link":"https:\/\/www.eabel.com\/de\/"},{"label":"Blog","link":"https:\/\/www.eabel.com\/de\/category\/blog\/"},{"label":"Server Rack Cabinet Sizes: Depth, Width &amp; Height","link":"https:\/\/www.eabel.com\/de\/server-rack-cabinets-sizes-depth-width-height-explained\/"}],"_links":{"self":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/posts\/36729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/comments?post=36729"}],"version-history":[{"count":4,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/posts\/36729\/revisions"}],"predecessor-version":[{"id":71640,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/posts\/36729\/revisions\/71640"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/media\/71641"}],"wp:attachment":[{"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/media?parent=36729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/categories?post=36729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eabel.com\/de\/wp-json\/wp\/v2\/tags?post=36729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}